Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1131 Results
Due to its full IP system architecture and distributed infrastructure, the CERTIUM VCS is perfectly suited for integration into a virtual center.
10-Mar-2014
R&S AVBrun, Broadcasting and Multimedia T&M, UltraHD R&S AVBrun Conformance testing solution for MHL/HDMI CTS sink/source R&S®AVBrun - Conformance testing solution for MHL/HDMI CTS sink/source R&S AVBrun, Broadcasting and Multimedia T&M, UltraHD R&S AVBrun Conformance testing solution for MHL/HDMI CTS sink/source R&S®AVBrun - Conformance testing solution for MHL/HDMI CTS sink/source R&S AVBrun, Broadcasting
14-Sep-2015
Rohde & Schwarz presents the R&S®ATS1000 antenna test system, a highly accurate solution for testing 5G antennas up to mmWave frequencies in a mobile shielded chamber.
17-Oct-2017
Rohde & Schwarz offers a complete test solution for WiMAX applications by combining its Signal Generator R&S SMU200A and Signal Analyzer R&S FSQ plus the appropriate options. This application note provides an overview of the differences between OFDM and OFDMA and demonstrates, how convenient it is to generate and analyze WiMAX OFDMA signals according to standard IEEE 802.16e-2005.
23-May-2007 | AN-No. 1EF58
Reflection measurements are a common way of assessing antenna system performance. When a minimum amount of the transmitted signal is reflected, it indicates that the transmission energy can reach the intended coverage. Undesired high reflection causes the system to be inefficient and can damage components. Reflection measurements can be expressed in terms of return loss, VSWR and reflection coefficient.
13-Nov-2017
This application note describes how to use the generic interface in R&S®AdVISE for remote operation.
19-Jun-2020 | AN-No. 1S002
Today virtually every electronic device has a standby mode. Power consumption is regulated in most countries by increasingly stringent limits. This makes standardized power measurement essential.
12-Sep-2018
A collection of frequently occurring customer questions on using the ZVR analyzer, calibration, virtual transform networks, and additional applications.
23-Jan-2002 | AN-No. 1EZ38
The power efficiency of the drive electronics is a key parameter when developing electric drive systems. The conduction loss of the electric drive electronics is of special interest. One important parameter for determining the conduction loss is the RDS(on) of the MOSFET. When a switching MOSFET is off, it has a high drain-to-source voltage, but when it is turned on, the voltage drops to just a few hundred millivolts. A highresolution oscilloscope is needed to measure these low voltages. Probe compensation and correct probing are also vital for accurate RDS(on) measurements.
19-Mar-2015
The R&S MATLAB® Toolkit for Signal Generators provides routines for remote controlling these instruments. Additional MATLAB® scripts turn I/Q vectors into the Rohde & Schwarz waveform file format for use with an ARB. This application note describes the installation and use of the R&S MATLAB® Toolkit on Microsoft Widows and Linux based systems.
26-Apr-2013 | AN-No. 1GP60
The R&S®ZNA vector network analyzer with integrated LO output and direct IF input options is a simple, cost-effective solution for 2-port and 4-port measurements using Rohde & Schwarz mmWave converters.
19-Jul-2021
Since the video signal - composite or component - is a most complex one regarding the spectral density or even the group delay in the baseband, you need special procedures to measure the signal parameters with an objective and absolute accuracy of less than one percent over the whole frequency range up to 6 MHz. The following describes a method allowing the precise measurement of a baseband signal, which then may be taken for the calibration of video analyzers such as the well-known R&S units UAF or UVF and future products.
20-Jul-2001 | AN-No. 7BM22
Starting from June 2017, almost all radio transmitters and receivers sold or put into operation in the European Union have to be tested for immunity against interferers in adjacent frequency bands. ETSI standard EN 303 340 defines the tests to be performed on digital television receivers and requirements to be passed.This application note describes the test procedures and provides save-recall files and interferer signals for the Broadcast Test Center R&S®BTC.
11-Jul-2017 | AN-No. 1GP116
Impedance measurements with vector network analyzers require maximum precision. The R&S®ZNL is able to characterize a broad range of impedances with the lowest uncertainty among its competitors in the same class.
02-Oct-2019
For the transmission of digial audio data, different data formats are in use. The AES/EBU format, which is used in professional applications, as well as the S/P DIF format used in consumer electronics, transmit the audio data in time multplex for both channels. Additonal bits in the data stream cover complementary information, respectively are used for error detection.The generation and the analysis of those protocol data using the audio analyzers UPD or UPL is the topic of this application note. An extract of the AES3 standard informs about the basic definitions.
04-Jun-1998 | AN-No. 1GA15
This application note shows how to configure the R&S®AdVISE visual inspection software to automate the immunity testing in line with EN 55020 and CISPR 35 on TV sets and monitors.
30-Jul-2020 | AN-No. 1S007
This application note provides a summary of the current test solutions available with Rohde & Schwarz equipment. The opportunities provided by the individual devices are presented briefly and a demonstration using a spectrum analyzer and a vector signal generator is described.
14-Sep-2009 | AN-No. 1MA112
Recording, converting and playing back real-world signals
13-Jul-2012
This application note explains the concept of Adjacent Channel Leakage Ratio (ACLR) measurement on 3GPP W-CDMA signals with the spectrum analyzer FSP. Optimum operation for both the integrated bandwidth method and the new time domain method are shown via explanation of the signal behavior and the internal structure of the FSP. With the time domain method the spectrum analyzer family FSP provides a new approach featuring a very short measurement time compared to the integrated bandwidth method.
12-Jan-2001 | AN-No. 1EF41
Air Traffic Control (ATC) radar, military Air Traffic Surveillance (ATS) radar and meteorological radar operate in S-Band frequency range. In fact 4G communication systems such as Long Term Evolution (LTE) make also use of these frequencies. Test and measurement of their coexistence is absolutely essential as performance degradation of mobile devices and networks and even malfunction of ATC radars has been proven.This application note describes LTE and S-Band radar coexistence test and measurement. It addresses LTE user equipment, base stations and S-Band radars and presents test solutions.
28-Mar-2014 | AN-No. 1MA211
PESQ measurements employ a level adaptation algorithm and are hence widely insensitive to absolute level. However, if the tests are performed via a speech codec, the driving level of the codec has an influence on the MOS result. Therefore careful alignment of the level is required. This application note provides an application program which runs on the Audio Analyzer R&S UPV or R&S UPV66 and can be used to calibrate signal levels for the PESQ measurement.
30-Jun-2011 | AN-No. 1GA50
This application note demonstrates the use of the Measurement Receiver to calibrate the signal output level of a Signal Generator.Calibration in this application is a two-step process.► The absolute output level of the signal source, at a fixed level, is measured using a thermal power sensor (e.g. NRP50T), which in turn outputs its reading to the FSMR.► Output power calibration over a wider dynamic range (to lower power) is performed by connecting the FSMR to the signal source directly, and sweeping the power of the signal source.The FSMR offers a nominal total measurement uncertainty of <0.015 dB +/- 0.005 dB per 10dB step. At 1GHz, the power measurement range covers -152 dBm to +30 dBm. It is this intrinsic linearity, that the accuracy of the calibration relies upon.Absolute power measurement uncertainty, for the NRP50T thermal power sensor used in this Application Note, is 0.040 dB to 0.143 dB.This process may be repeated at multiple frequencies. Calibration values are automatically stored and managed by the FSMR. Measurement frequencies for calibrations are stored, will be automatically recalled by the FSMR, by re-selection of those frequencies.
31-Dec-2021 | AN-No. 1SL377
This application note shows how to run 3GPP WCDMA BER and BLER tests according to standard TS 25.141 with the Vector Signal Generators R&S®SMBV100A, R&S®SMJ100A, or R&S®SMU200A. The description of hardware test setup is followed by detailed instructions on how to configure the R&S® generators and how to run a BER or BLER test step by step. Remote control commands for the generators are included, to simplify integrating the BER/BLER tests into your proprietary test suite.
06-Mar-2009 | AN-No. 1MA144
The present R&S®SMW-K506 Interface Control Document contains information on► the R&S descriptor word format, including ARB descriptor words and control descriptor words in deterministic and instant mode► Timing requirements and limitations of the interface► Properties of the network interface (Connector designation: HS DIGIQ).It is intended for use by customers using descriptor words to control the R&S®SMW200A in real-time. The interface control document specifies the interface between the customer’s hardware used for provision of descriptor words and the R&S®SMW200A HS DIGIQ interface. Additional information on descriptor word processing inside the R&S®SMW200A is provided.
17-Mar-2022 | AN-No. 1GP134
Distortions caused by components in the RFFE (radio frequency front end) limit the performance and throughput of communications systems. Types of distortions include:▪ AM-AM and AM-PM (complex variations of gain with amplitude)▪ Non-linear frequency response (memory effect)All RFFE components exhibit all of these distortions, only the proportions vary. In this Application Note, illustrative measurements of individual RFFE components, as well as a complete RFFE, will be made. This is followed by the documentation of a more complete analysis, including comparison against theoretical limits, of a linearized commercial SatCom BUC product.
27-Feb-2017 | AN-No. 1MA299
The purpose of this document is to provide a step-by-step guidance on how to perform VESA compliance testing on DisplayPort 80 cable assembly.Throughout this Method of Implementation (MOI), procedures will detail how to perform such VESA compliance testing using the R&S® ZNB lineup of Network Analyzers.
19-May-2025 | AN-No. 1SL414
The R&S®ZNB vector network analyzer is easy to configure and calibrate using the built-in intermodulation wizard.
19-Dec-2013
Digital pre-distortion (DPD) is a common method to linearize the output signal of a power amplifier (PA), which is being operated in its non-linear operating range.Most PAs operate in their non-linear range for efficiency reasons. The drawback of higher efficiency is the non-linear operating range. In order to maintain signal quality, many transmitters employ DPD. Implementing real-time DPD in a transmitter is a challenging task and often ends in PA models, which are specific to the signal transmitted.Even though these complex models are required for transmitter development, they are not needed during PA verification and development.This article describes an approach to generate a pre-distorted signal based on a hard-clipper. The resulting waveform pushes the output of the DUT as close to the hard-clipper as possible.Due to the waveform approach, the algorithm compensates all memory effects.
13-Sep-2017 | AN-No. 1EF99