I am using the command “CONT:AUX:C x” to see when a channel is active. But the respective pin at the AUX connector does not switch to “high”.
I got a calibration kit with a sliding match standard. But there are no correction values for the NWA supplied.
How can I export the traces of a specific channel into one file, i.e. CSV?
I perform a calibration with remote commands. With the command to start the calibration sweep with a short standard I get this error message. What is the problem?
Provides the information required to prepare the instrument for use and start working.
ZNB, ASCII export of displayed trace values
When I export the time domain trace the stimulus values are in Hz, but not in seconds as shown on the screen. How can I get the export in time or distance?
I need to activate the deembedding function on a specific port. The data is available on a touchstone file (s2p) How can I load the file with remote commands?
The R&S®ZNB vector network analyzer features a diverse number of measurement options.
The R&S®ZNB vector network analyzer offers solid RF performance for your everyday needs.
Is it possible to automatically restart a ZNB with return of the AC power?
The multi-touch capability of the R&S®ZNB ensures a smooth and easy operation of the instrument.
Vector network analyzer ZNB, Test and Measurement, Network analyzers, network analysis, ZNB Vector network analyzer features a wide dynamic range, low trace noise and high output power necessary in electronic goods and mobile radio industry.
The R&S VNAs, e.g. the R&S ZNB have new deembedding options integrated into the FW, which can easily be run with the R&S VNA. De-embedding, ZNB, VNA The R&S ZNB have new deembedding options integrated into the FW, which can easily be run with the R&S VNA.
This application note introduces the IVI High Speed LAN Instrument Protocol (HiSLIP) and outlines its features. HiSLIP is the successor to the VXI-11 LAN remote control protocol. This document also describes guidelines for using this protocol.
12-Nov-2014 | AN-No. 1MA208
Remote Desktop connection
As DisplayPort evolves to support ultra-high resolutions and increased data rates, robust compliance testing is essential to ensure interoperability across devices and interconnects. This application note provides a structured overview of physical-layer testing for DisplayPort source transmitters and passive cables, aligned with VESA CTS v2.1. The note covers key test procedures using Rohde & Schwarz solutions, including oscilloscope-based measurement at standardized test points, automated test execution with ScopeSuite, and signal integrity debug via equalization and jitter decomposition. It further details cable characterization using mixed-mode S-parameter analysis on a Vector Network Analyzer (VNA), with support for simulated eye diagrams and TDR-based impedance diagnostics. Practical setup examples and product references are provided to help engineers perform repeatable, standards-compliant DisplayPort PHY validation.
16-Jul-2025 | AN-No. 1SL418
Reverse sweep / backward sweep
Installing a USB-GPIB adapter
Bias tee limits and calibration considerations
Remote control autocalibration with a calibration unit
SCPI remote error message on the display
External generator connected via USB not correctly recognized
License Keycode for VNAMUC is not accepted
The MINUS key on the keypad does not work.
Save/recall files: own folder in 'Look In'
How can I start a SSST calibration?
Calibration of two channels simultaneously with remote commands
I have an existing limit line. Is it possible to apply a vertical offset?