9085 Results
This document describes a method to separate common-mode and differential-mode separation using two oscilloscope channels. This separation approach works without any additional hardware component.
17-Sep-2020 | AN-No. GFM353
Smartly verify and decode Bluetooth® Low Energy (BLE) transmit signals with a reliable and costefficient spectrum analyzer – the R&S®FPC.
17-May-2018
Optimizing electric drivetrains with MXO oscilloscopes
12-Mar-2024
Operating Guide for WCDMA Test Setup according to 3GPP TS34.121
15-Apr-2009 | AN-No. 1CM71
This paper describes the characterization of aluminum electrolytic capacitors specifically used in AC-DC power converter applications. It will be discussed why this capacitor technology is critical regarding lifetime and why it cannot be substituted simply by any another capacitor technology. Different aging effects of the capacitor will be discussed. Usage of the capacitor in different AC-DC converter topologies will be presented. Simulation circuits will be used to analyze the capacitor in more detail before suitable measurements will be performed to demonstrate a real example of a switching-mode power supply (SMPS).After the introduction into the aluminum electrolytic capacitor basics and theory, this paper will also present all important and possible measurements of capacitor parameters, like capacitance, equivalent series resistance (ESR) and ripple current. This includes in-circuit measurement which can be performed with an oscilloscope. An LCR-bridge is used to obtain high accuracy measurements in addition. A comparison between the two measurement methods will be presented. Furthermore, the required measurement hardware for the in-circuit measurements and the bridge measurement will be discussed and presented.Lastly, two different lifetime calculation methods are presented and a real example is used to compare the advantages and disadvantages of the different methods.Thanks to Mr. Frank Puhane from Würth eiSos GmbH & Co. KG who provided me with all aluminum electrolytic capacitor samples including the prepared capacitor with build-in temperature sensors to perform all measurements. Furthermore, his great expertise was very beneficial and helpful to create this premium application note.
07-Feb-2023 | AN-No. 1SL388
RF Level Measurement Uncertainties with the Measuring Receiver R&S FSMR
28-Mar-2006 | AN-No. 1MA92
LTE beamforming can be accurately tested with one or more R&S®RTO digital oscilloscopes for a 1×2, 1×4 or even a 1×8 MIMO system.
08-Aug-2024
The super-resolution DF method determines bearings of multiple emissions on the same frequency.
04-Mar-2016
The R&S®SMW-K501 and R&S®SMW-K502 options from Rohde & Schwarz enable engineers to quickly model complex pulse scenarios.
06-Jun-2017
Solutions and Tipps for NR FR1 in TDD Downlink Mode
5G New Radio (NR) is a radio technology specified by 3GPP and was first released in 3GPP release 15. It is designed to target three use cases, i.e. enhanced mobile broadband (eMBB), massive machine type communication (mMTC) and ultra-reliable low latency communication (URLLC). Among these three use cases, eMBB represents actually a further evolution of mobile broadband communication from LTE standard. According to the technical performance requirement defined by IMT-2020, by deploying 5G technology, peak data rates of eMBB application are expected to reach 20 Gbps in downlink (DL) and 10 Gbps in uplink (UL) direction, respectively. Typical use cases of eMBB are data hungry applications, such as high resolution 8K video streaming, virtual reality (VR), augmented reality (AR) etc.Verification of a 5G capable user equipment (UE) with respect to its achievable maximum data throughput under controllable and deterministic test conditions is an essential process during the design phase of the product. Performance centric verification through identification of the data throughput bottleneck, product benchmarking against a golden device enhances tremendously the user experience in the end.This document focuses on 5G NR frequency range 1 (FR1) with TDD duplex mode in E-UTRAN New-radio Dual Connectivity (ENDC) operating mode. As 5G NR physical layer offers a plethora of flexibility, the motivation here is to provide a kind of guideline of relevant parameter settings to stimulate device under test (DUT)'s max throughput capacity. The status quo of the R&S solutions at the time when the application note is created are described. Shown feature sets are constantly evolving, so the screenshots used and the parameters shown may change.
07-Jul-2022 | AN-No. 1SL379
In this document we will describe in detail how to configure and perform path calibrations with AMS32-K81 in an ATS1500C, using an AREG800A.
03-May-2023 | AN-No. 1SL399
Crime scene investigation with cellular network analysis
14-Mar-2024
5 kW HF HIGH-POWER TRANSMITTERS FOR AIR TRAFFIC SERVICE
17-May-2023
This application note briefly summarizes the history of SCPI and outlines in which fields of application a SCPI based test system software has still advantages over a driver (e.g. IVI) based approach.
18-Oct-2017 | AN-No. 1GP98
Operation Guide for HSDPA Test Setup according to 3GPP TS 34.121
13-Oct-2009 | AN-No. 1CM72
Verifying power integrity for DDR memories - The R&S ® RT-ZPR20 power rail probe is a specialized oscilloscope probe for very low-noise measurements on power.
05-Apr-2017
This document answers frequently asked questions regarding Rohde & Schwarz Broadband Amplifiers. It describes remote operation and monitoring of the R&S® Broadband Amplifier series through a standard web browser.
04-Nov-2016 | AN-No. 7TA1
With continuously increasing data rates, signal integrity in high speed digital designs becomes more and more demanding
08-Jul-2022
Tests of Audio Amplifiers in Accordance with Standard IEC 60268-3
13-Feb-2008 | AN-No. RCS0704-0032
This paper provides an important insight into the design and measurement challenges around the key topic of 5G New Radio in collaboration of a number of industry partners.
26-Nov-2018
High Speed Downlink Packet Access (HSDPA) Test and Measurement Requirements
01-Feb-2005 | AN-No. 1MA82
Increasing safety in air traffic control: R&S Series4200 detection of simultaneous transmissions (DSiT) option for air traffic control.
21-Aug-2014
In the satellite sector, components, subsystems and entire satellites must be qualified in a thermal vacuum chamber before they can be used in space. This qualification proves that equipment can not only survive but also function in the harsh conditions encountered during launch and in space.
05-Oct-2022
Level Error Calculation for Spectrum Analyzers
13-Jan-1998 | AN-No. 1EF36
This white paper provides an overview of test solutions addressing current and future requirements for antenna verification.
11-Nov-2016 | AN-No. 1MA286
MIPI D-PHY is a low-power, cost-effective physical layer interface, essential in mobile devices and advanced technology systems. It's a high-speed, source-synchronous interface used in smartphone cameras, smartwatch displays, drones, in-car entertainment, automobile cameras, and radar sensors. This application note explores MIPI D-PHY's features, functionality, and testing practices for device compliance, addressing common issues. It highlights Rohde & Schwarz's equipment for ensuring compatibility and solving issues with MIPI D-PHY, aligned with MIPI D-PHY specification version 2.5.Developed by the MIPI Alliance, D-PHY connects cameras and displays to a host processor via CSI-2 or DSI protocols. It features a master-slave, asymmetrical design for reduced link complexity. Key aspects include a unidirectional clock, optional data signal directions, different data rates for half-duplex operation, point-to-point communication, and high-speed (HS) and low-power (LP) modes for data transfer and battery preservation. In HS mode, D-PHY uses differential signaling with specific impedance, while in LP mode, it operates in a single-ended manner with high impedance termination.The application note from Rohde & Schwarz provides insights into characterizing and debugging MIPI D-PHY, offering conformance verification with MIPI Alliance standards and protocol decoding options.
31-Jan-2024 | AN-No. 1SL410
The R&S®Pulse Sequencer software offers an easy way to simulate moving radar emitters and a moving receiver for EW receiver tests.The software together with the R&S®SMW200A vector signal generator is a powerful radar simulator
18-Sep-2018
The R&S®SMA100B offers outputs for the analog input signal of the ADC as well as the clock input signal in one single instrument - both with outstanding signal purity.
11-Jan-2021 | AN-No. 1GP66
Distance-To-Fault (DTF) Measurement in 75 Ohm Systems with the R&S FSH3-TV
21-Sep-2006 | AN-No. 7BM60