FAQ; À chaque fois que je démarre mon EMC32, un message d'erreur inattendu s'affiche : "ikey for AMS32 could not be found". Que faire ?
After calibration I received updated attenuation and transducer tables. How do I enter these values into the EMC32 Explorer to continue new Tests with these values?
EMC32: Interactive data reduction, difference between "After data reduction" and "Before final measurements".
EMC32 : comment le rapport standard se réfère-t-il aux mesures dans les chambres semi-anéchoïques ?
EMC32, Download Transducer Factor to Test Receiver
FAQ : Contrôle des extensions EMC32
Cette note d'application montre comment configurer, calibrer et effectuer des mesures EMS conduites selon la norme IEC / EN 61000-4-6 et des mesures EMI selon la norme CISPR 16-2-1 avec le logiciel R&S®EMC32.
juil. 19, 2013 | Numéro des notes d'application 1MA212
So far I only have experience how to add a transducer to a slidebar, a 2-Line-LISN or 4-Line LISN. Now, I want to add a transducer for an 8-Wire ISN (e.g. ENY81) to EMC32.
EMC32 measurements with more than 1000000 points
EMC32, Level Sweep shape during Reference Calibration
Que puis-je faire pour configurer un transducteur valide ?
FAQ : Quand ai-je besoin de l'administration des utilisateurs EMC32 ?
EMC32, display preview results of all LISN phases
Niveau d'immunité non atteint - Interruption du balayage EMS
Afficher le graphique d'un transducteur avec EMC32
Est-il possible d'implémenter un plateau tournant qui puisse être commandé en utilisant le logiciel EMC32 avec mon récepteur EMI ?
How can I add a attenuation table to my cable, used in my measurement setup?
Using R&S®ELEKTRA Migration Tool
The R&S®ELEKTRA EMC test software is the successor of the R&S®EMC32 EMC measurement software. Like the R&S®EMC32 EMC measurement software, the R&S®ELEKTRA offers a solution that controls complete EMC systems and automates measurements on equipment under test (EUT) that is being tested for emissions (EMI) and immunity (EMS) compliance. It has more features and test types compared to R&S®EMC32.As both software platforms use different file formats, R&S®EMC32 users who upgrade their existing software to the R&S®ELEKTRA platform need to perform a file conversion before migrating their data to the R&S®ELEKTRA platform. This is done by using the R&S®ELEKTRA Migration Tool, which is installed automatically with each R&S®ELEKTRA installation.This Application Note describes how to use the R&S®ELEKTRA Migration Tool (version 4.4 onwards) for converting the backup data into the XML format that can be interpreted by the R&S®ELEKTRA software. It also provides recommended conversion steps (Chapter 5) and troubleshooting tips (Chapter 6). For instructions on migrating the data using R&S®ELEKTRA Migration Tool below version 4.4, refer to the R&S®ELEKTRA user manual. For better user experience, we recommend using the latest software version for migration.This Application Note does not describe the steps to backup data using the R&S®EMC32 or R&S®ES-SCAN software. For procedures on how to do so, refer to their respective manuals.
May 04, 2023 | Numéro des notes d'application 1SL396
EMC32, gammes de fréquences dans la recherche "Subrange Maxima"
Use of the ESW build in Pulse Limiter, if remote controlled by EMC32
Dans les graphiques d'un test, est-il possible de toujours laisser la légende active ? Ainsi, nous n'avons pas besoin de l'insérer à chaque fois que le test est terminé ?
Découvrez comment résoudre le problème dans le cas où vous recevez le message d'erreur "Application will be closed" au démarrage de l'EMC32.
Lorsque j'exécute le test et que je reviens en arrière pour changer les paramètres dans Test Template, comment puis-je sauvegarder les nouveaux réglages ?
I recently exported the results table from a test, and realized it had been truncated at line 65535. I tried a few more times, but the result was the same. What is the reason for the limitation?
Mise à jour de macros API dans EMC32
En utilisant le plateau pivotant, l'ajustement final fonctionne sur la gamme complète (de -180 à +180°), également si je défini une "predefined range" de 60°-
R&S EMC32-K27 Dual Receiver Measurement (DRM) - Flyer
Questions répétitives. Fichiers de forme d'onde TS8997 introuvables sur le générateur de signaux vectoriels
Nous devons pouvoir envoyer deux commandes une par une. Est-ce possible ?
Différent des réglages par défaut, je voudrais effectuer un test de puissance de perturbation de par exemple 300 à 500 cm