Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1139 Results
This application note describes the use of R&S®GTSL and R&S®EGTSL in a .NET programming environment. It shows the user how libraries and drivers generated using the C programming language can be used in applications based on .NET technology.
08-Mar-2016 | AN-No. 1SE001
An FSE Spectrum Analyser equipped with the Vector Signal Analysis option (FSE-B7) can measure oscillator settling time or transmitter attack and release times with high accuracy up to 40 GHz. No additional measurement equipment is needed.
12-Feb-1999 | AN-No. 1MA15
This application note describes how to verify and validate a LTE (FDD) RF chipset using R&S® SMU200A vector signal generator, R&S® FSQ signal analyzer and R&S® EX-IQ Box. The related signal generation as well as signal analysis is described
19-Dec-2008 | AN-No. 1MA138
Due to its outstanding performance the R&S®SMW200A vector signal generator is ideal for testing MIMO receivers in a vast variety of applications offering maximum usability at minimum form factor. It can generate up to eight antenna signals simultaneously in its digital baseband – all standard-compliant and with antenna-specific coding. In addition, it can simulate the complete MIMO transmission channel with up to 32 fading channels, sufficient to emulate higher-order MIMO configurations such as 3x3, 4x4, and 8x4.This application note explains how to use the SMW for testing higher order MIMO systems by presenting different key applications.
24-Feb-2016 | AN-No. 1GP97
Application note 1MA25 has been replaced by application note .
28-Aug-2009 | AN-No. 1MA25
Signal generators play a vital role in electrical test and measurement. They generate the test signals that are applied to components such as filters and amplifier, or even to entire modules, in order to ascertain and test their behavior and characteristics. The first part of this educational note presents the applications for and the most important types of signal generators. This is followed by a description of the construction and functioning of analog and vector signal generators. To permit a better understanding of the specifications found on data sheets, a closer look at the most important parameters for a signal generator is provided.Beyond the output of spectrally pure signals, a key function of RF signal generators is the generation of analog- and digitally modulated signals. The second part of this note therefore presents the fundamentals for the most significant analog and digital modulation methods.The third part of this educational note contains exercises on the topics of analog and digital modulation. All described measurements were performed using the R&S®SMBV100A vector signal generator and the R&S®FSV spectrum analyzer.
03-May-2016 | AN-No. 1MA225
For customers who have already used automated R&S SFQ setups in development and production, the implementation of the successor instrument results in a need to adjust the SCPI commands formerly used.This document provides an overview on how SCPI commands that are used with the R&S SFQ change with the new test transmitter as well as a cross-reference list in the form of an EXCEL sheet.
23-Jun-2006 | AN-No. 7BM56
This Application Note describes two programs for calculating conversions: 1.: The Power Unit Calculator Power, dBm, dBmV and Volts @ 50 W 2.: The VSWR Calculator Reflection, VSWR, Return loss and Power reflection Reflections, Reflectionl to Mismatch Uncertainty.
03-Jul-1998 | AN-No. 1MA12
Correct and time-saving parameter configuration thanks to predefined DVB-T2 test configurations in the R&S®SFU broadcast test system
18-Apr-2013
The battery life measurement solution for the R&S®CMW500 platform identifies which ECUs and which applications running on telematics units impact battery life.
23-Aug-2017
A programmable data generator such as the combination of SME with option SME-B11 is a novelty with signal generators. To make it easy for the user to get acquainted with the option and to ensure efficient operation, possible applications are described below. The data generator is used for producing binary data as well as control signals for level switching whenever digitally modulated signals are used. For a start we should like to deal in brief with the various settings available for digital modulation. Taking GSM as an example, the programming of data lists will be described next. The description for GSM can be easily applied to other digital networks as well. Next the generation of level bursts and the extension of data generator memory with option SME-B12 are described. The last section deals with special subjects such as FSK using data rates below 400 bits/s and pulse-amplitude modulation. A basic knowledge on digital modulation and TDMA will be sufficient to follow the topics.
01-Jul-1999 | AN-No. 1GPAN08
Multiple Input Multiple Output (MIMO) is an integral part of LTE. Vector signal generators and signal & spectrum analyzers from Rohde & Schwarz support LTE measurements with up to 4 antennas. This Application Note covers 2x2 MIMO in the LTE downlink. Remote control programming is demonstrated by examples for a free-of-charge program.
09-Oct-2014 | AN-No. 1MA143
The application note describes the Measurement Uncertainty Analysis Program NRV-Z. The program is used to determine measurement uncertainties that inevitably arise when using power meters. In particular, it covers the NRV-Z family of thermal sensors and diode sensors for high-precision power measurements, as well as the compatible basic units NRVD, NRVS and URV55.
26-Jul-2001 | AN-No. 1GP43
An FSE (or FSIQ) Spectrum Analyser equipped with the Vector Analysis option (FSE-B7) can measure a wide range of error types (EVM, Magnitude Error, Phase Error…) on continous signal. This Application Note describes how to measure these errors on a single burst between symbols.
22-Jan-2011 | AN-No. 1ES48
Software tools allow to make the control of T&M instruments more convenient. The adoption of the following tools for Windows®-based T&M instruments is described: ● Synergy:One mouse and one keyboard control a group of T&M instruments ● CamStudio:Video clips of the display of a T&M instrumentare recorded during operation
13-Jun-2013 | AN-No. 1MA218
Stable operation in all circumstances is essential for power converters. Different working conditions, such as load steps, startup/shutdown sequences and input voltage variation, apply to most converter types. In addition to the standard feedback control loop, integrated pulse width modulation (PWM) controllers provide extended functions, such as line feed-forward loop control and soft-start control. These extended control functions improve regulation for specific conditions. Such complex regulation systems require smart methods to ensure proper operation of the converter in all modes. For this task, extensive expertise and the right measurement tools are essential for identifying and locating unexpected events in the system.
11-Oct-2023
Frequency converters e.g. in satellite transponders need to be characterized not only in terms of amplitude transmission but also in terms of phase transmission or group delay, especially with the transition to digital modulation schemes. They often do not provide access to the internal local oscillators. This application note describes a method using the R&S®ZNA analyzer family to measure group delay of mixers and frequency converters with an embedded local oscillator very accurately. The key aspect of this new technique is that the network analyzer applies a 2-tone signal to the frequency converter. By measuring the phase differences between the two signals at the input and at the output, it calculates group delay and relative phase.
11-Jul-2019 | AN-No. 1EZ81
The purpose of the test setup described is to ensure or to enhance the level accuracy of signal generators or the generator part of communication testers. The level accuracy of test signals is particularly important at low levels when measuring BER level sensitivity at digital communication receivers. The highly linear FSP spectrum analyzer is used in combination with a power meter to get the best possible accuracy with high measurement speed over a very wide level range.
18-Feb-2011 | AN-No. 1MA21
Your measurement task: To analyze an RF module via its digital interface. This Application Note explains how. As interfaces between the baseband and the RF modules of mobile radio base stations and terminals are increasingly digital, instruments for testing such modules need digital baseband interfaces as well. The R&S®EX-IQ-Box is a digital interface adapter that provides digital baseband I/O for Rohde & Schwarz signal generators and signal analyzers. An R&S signal analyzer with digital baseband interface R&S®FSQ-B17 can analyze digital baseband components input from the R&S®EX-IQ-Box. Data collected with a test-setup consisting of an R&S signal analyzer and the digital interface adapter R&S®EX-IQ-Box can be used in an Agilent ADS environment. For details of how to input the results to ADS, see Application Note 1MA72: 'Using R&S® Instruments within Agilent®ADS®Software'
26-Jun-2009 | AN-No. 1MA147
This Application Note introduces HSDPA technology and test and measurement requirements according to 3GPP release 5 specifications. Important HSDPA measurements and example applications are illustrated by means of Rohde & Schwarz products.
01-Feb-2005 | AN-No. 1MA82
R&S®Series4200 detection of simultaneous transmissions (DSiT) option for air traffic control
21-Aug-2014
The R&S®SMC100A signal generator offers a remote emulation feature that makes it possible to control the instrument by commands other than the built-in native SCPI commands. This feature allows the user to replace signal generators, e.g. from other manufacturers, with the R&S®SMC100A without having to change the remote control code. This application note describes how to use the remote emulation feature in general. Furthermore, it describes in detail the remote emulation for each supported instrument, limitations of the individual emulations and the remaining differences between the emulated and the original commands.
28-Feb-2012 | AN-No. 1GP90
VCS-4G, secure Communications, VoIP, air traffic contro, EUROCAE, ED‑137, ATC, CERTIUM, CERTIUM VCS test system Rohde & Schwarz solution CERTIUM VCS CERTIUM VCS test system for aircraft manufacturers VCS-4G, secure Communications, VoIP, air traffic contro, EUROCAE, ED‑137, ATC, CERTIUM, CERTIUM VCS test system Rohde & Schwarz solution CERTIUM VCS CERTIUM VCS test system for aircraft manufacturers VCS
01-Aug-2023
Level or power measurement of especially modulated signals using spectrum analyzers is becoming more and more important . Whereas the first choice in terms of accuracy for power measurement of any carrier (modulated or non-modulated) is a power meter, power measurement of spurious or in the adjacent channel of a transmission system needs a selective power meter with high dynamic range. A power meter, however, is a non-selective device with limited dynamic range and is not appropriate for these types of measurements. The first choice is a spectrum analyzer because of its versatile use as a general-purpose instrument. Compared to a power meter its power measurement accuracy is worse. In general this can be overcome by substitution methods using a power meter, an attenuator and a signal generator. But substitution is time-consuming and requires more investment in test equipment than a single instrument. Therefore it is most important to have a spectrum analyzer like the FSE, which can fulfill at least most of the requirements in terms of measurement accuracy.
13-Jan-1998 | AN-No. 1EF36
5G networks will need to offer more capacity and flexibility while lowering the operational expenses of the system. Two new technologies can simultaneously address both the increase in capacity and the increase in energy efficiency: Virtualization & Massive MIMO. This white paper provides an overview of test solutions addressing current and future requirements for antenna verification including both conducted and over-the-air (OTA) test methods, which result from applying Massive MIMO antenna technology.This white papers complements the white paper (1MA276) from Rohde & Schwarz, which introduces fundamental theory behind beamforming antennas and provides calculation methods for radiation patterns, a number of simulation results as well as some real world measurement results for small linear arrays.
11-Nov-2016 | AN-No. 1MA286
In order to clearly visualize and make repeatable measurements on signals with amplitudes of less than 1/100 of a division, and stabilize signals captured over very long periods, the R&S®RTO oscilloscope’s powerful combination of measurement and math channel capabilities allows corrective offset adjustments on individual acquisitions more than one hundred times per second.
10-Sep-2015
Many applications in aerospace and defense as well as in mobile communication require a defined magnitude and phase relation between several signals, for example, to design a smart antenna array and it's distribution network, or to ensure accurate phase alignment between different transmitter or receiver chains of T/R modules. Magnitude can be measured with spectrum analyzers or power meters. For phase measurements, a vector network analyzer is the easiest, fastest and most accurate instrument.This application note shows how to measure the phase accurately between several signals using vector network analyzers of the R&S®ZNA, R&S®ZNB and R&S®ZNBT families.
11-Jul-2019 | AN-No. 1EZ82
The measurement accuracy of vector network analyzers can be tested simply, easily and quickly, with a simple DUT which consists of a common tee-junction with one port, terminated with a resistive load Z, and the T-Check program. The four S-parameters from ports 1 and 2 are measured with the vector network analyzer to be checked and then evaluated by means of the T-Check software.
04-Aug-1998 | AN-No. 1EZ43