214 Results
See how you can use this standard feature on MXO oscilloscopes easily and reliably. Use zone trigger to define trigger events graphically. See how you can use this standard feature on MXO oscilloscopes easily and reliably. Zone Trigger The integrated arbitrary waveform generator provides stimulus output of different waveforms including noise to your device under test.
This document provides the technical specifications of the R&S®ScopeStudio software.
See how you can use this standard and unique capability on MXO oscilloscopes to trigger on specific events on your math signal. Use zone trigger to define trigger events graphically, also on your math signals. See how you can use this standard and unique capability on MXO oscilloscopes to trigger on specific events on your math signal.
01-Mar-2023 | Press Releases
Embedded world 2023: Rohde & Schwarz showcases its state-of-the-art test solutions for embedded systemsEmbedded systems are at the core of today’s electronic devices, whether in consumer electronics, telecommunications, industrial, medical, automotive or aerospace applications. Flawless operation is crucial, and engineers face complex challenges when designing ever more compact embedded systems which meet today’s demands of efficiency, safety, reliability and interoperability. Rohde & Schwarz addresses these challenges with its wide-ranging test and measurement solutions showcased at the embedded world Exhibition & Conference 2023 in Nuremberg.
R&S®MXO 5 - Evolved for more challenges Integrated Waveform Generator Integrated Waveform Generator
Oscilloscope application software for PCs: Enhance your oscilloscope experience
Selecting Your Next Oscilloscope:
If you are selecting your next oscilloscope and want more insight on how to understand ENOB values measured and published by oscilloscope manufacturers, this document is for you. The effective number of bits (ENOB) is a way of quantifying the quality of analog to digital conversion. A higher ENOB means that voltage levels recorded in analog to digital conversion are more accurate. Understanding oscilloscope vendor-supplied ENOB values can be complex. This document focuses on interpretation of measured ENOB results made on oscilloscopes rather than the math behind ENOB calculations.
21-Jun-2024 | AN-No. 1TD12
MXO 4 - See the difference This video shows you how you can better place and stabilize your probes using the the Rohde & Schwarz 2D positioner for passive probes and the 3D positioner for other probes. This video shows you how you can better place and stabilize your probes using the the Rohde & Schwarz 2D positioner for passive probes and the 3D positioner for other probes.
20-Jan-2025 | Press Releases
Rohde & Schwarz to host the 2025 Digital Debug Design Challenge at DesignConRohde & Schwarz, a leading provider of high-performance test and measurement solutions, has announced their plans for the upcoming DesignCon 2025 tradeshow.
The R&S®RTx-K36 frequency response analysis option provides a low-cost alternative to low frequency network analyzers or dedicated standalone frequency analyzers.
18-Dec-2018
MXO 4 - See the difference Quickly and reliably trigger and decode packets from your SPI bus using either the analog or digital channels as serial bus inputs. See how you can flexibly configure the trigger or display the decode table. Quickly and reliably trigger and decode packets from your SPI bus using either the analog or digital channels as serial bus inputs.
MXO 4 - See the difference Quickly and reliably trigger and decode packets from your RS232 or RS485 buses using either the analog or digital channels as serial bus inputs. See how you can flexibly configure the trigger, change the data format or display a decode table.
MXO 4 - See the difference Quickly and reliably trigger and decode packets from your I2C bus using either the analog or digital channels as serial bus inputs. See how you can flexibly configure the trigger, change the bit rate or threshold voltage or display a decode table.
MXO 4 - See the difference Quickly and reliably trigger and decode packets from your LIN bus using either the analog or digital channels as serial bus inputs. See how you can flexibly configure the trigger, change the bit rate or threshold voltage or display a decode table.
このR&S®RT-ZM モジュラープローブ・システムは、現在のプロービング要件に対応する、高度な技術と使いやすさを兼ね備えたソリューションです。
R&S®RT-ZM Modular Probe System은 정교한 기술과 간단한 사용법으로 오늘날의 프로빙 요구 사항을 해결합니다.
The R&S®RT-ZM modular probe system addresses current probing requirements with a technologically sophisticated yet easy-to-use solution.
This document provides: - An explanation of analog versus digital triggering architectures - User advantages for oscilloscopes that have digital triggering - How to determine if an oscilloscope has a digital or analog trigger
本白皮书包含以下内容:- 模拟和数字触发架构 - 数字触发示波器的优势 - 如何辨别数字或模拟触发示波器
This document provides: - An explanation of update rate - How users can quickly perform their own update rate characterization - How to compare vendor update rates - Benefits of fast update rate
Selecting your next oscilloscope: Why fast update rate matters | 选择下一代示波器: 为什么更高的波形捕获率很重要 - White Paper Brochures and Data Sheets White Paper
An offline AC/DC switching converter has no separate bias power supply that provides power to the control integrated circuit itself. Here, an auxiliary primary winding and discrete components are added to supply power to the control circuit. Verifying this circuitry is essential and requires accurate and detailed signal level and timing measurements. The startup sequence takes a long time, which needs to be taken into consideration in the measurement and requires an instrument with sufficient memory.
23-Nov-2022
Sometimes auxiliary functions generate emissions infrequently, making it challenging to locate and isolate the root cause. An instrument with a very fast FFT analysis capability is essential to find infrequent events efficiently.
03-Mar-2023
Power converters with a full-bridge topology are frequently used in telecommunications and servers that need to be compact, efficient and cost sensitive, making them more complex. Switching patterns for all the main primary switches including synchronous rectifier switches need to be validated after the first protype is built. This complex validation requires proper measurement of switching patterns to prevent catastrophic switching patterns. Expertise and the right measurement tools are essential when identifying unexpected events in the converter switching process.
17-Jan-2024
Stable operation in all circumstances is essential for power converters. Different working conditions, such as load steps, startup/shutdown sequences and input voltage variation, apply to most converter types. In addition to the standard feedback control loop, integrated pulse width modulation (PWM) controllers provide extended functions, such as line feed-forward loop control and soft-start control.
11-Oct-2023
Oscilloscope innovation. Measurement confidence. | Инновационные осциллографы | Достоверные результаты измерений. Brochures and Data Sheets Flyer
Oscilloscope innovation. Measurement confidence. - Flyer Brochures and Data Sheets Flyer
Oscilloscope innovation. Measurement confidence. - Flyer Brochures and Data Sheets Flyer
Oscilloscope innovation. Measurement confidence. | オシロスコープの革新、測定の核心に迫る。 - Flyer Brochures and Data Sheets Flyer
12-Feb-2025 | Press Releases
True spectrum dominance in all domains: Rohde & Schwarz unveils cutting-edge solutions at IDEX 2025Rohde & Schwarz showcases its latest cutting-edge defense solutions at IDEX 2025, empowering true spectrum dominance for operational scenarios in all domains and along the complete signal chain.