Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1143 Results
Today’s digital designs and high-speed data converters require clean clocks with minimal jitter
03-Aug-2017
Selecting Your Next Oscilloscope:
If you are selecting your next oscilloscope and want more insight on how to understand ENOB values measured and published by oscilloscope manufacturers, this document is for you. The effective number of bits (ENOB) is a way of quantifying the quality of analog to digital conversion. A higher ENOB means that voltage levels recorded in analog to digital conversion are more accurate. Understanding oscilloscope vendor-supplied ENOB values can be complex. This document focuses on interpretation of measured ENOB results made on oscilloscopes rather than the math behind ENOB calculations.
21-Jun-2024 | AN-No. 1TD12
An offline AC/DC switching converter has no separate bias power supply that provides power to the control integrated circuit itself. Here, an auxiliary primary winding and discrete components are added to supply power to the control circuit. Verifying this circuitry is essential and requires accurate and detailed signal level and timing measurements. The startup sequence takes a long time, which needs to be taken into consideration in the measurement and requires an instrument with sufficient memory.
23-Nov-2022
The RSIB interface enables the network analyzers of the ZVR family to be controlled by means of Windows applications via DDE. The interface functions are contained in the DLL RSIB.DLL. The other DLL RSDDE.DLL provides functions for the DDE access to the instrument firmware. These functions are used by RSIB.DLL. The interface of these functions greatly corresponds to that of National Instruments for programming the GPIB. The function names are similar to those of the NI library but preceded by RSDLL. The two DLLs are part of the firmware and are updated with the firmware update kits.
31-Jul-1998 | AN-No. 1EZ33
The R&S®SMBV100B signal generator offers a remote emulation feature that makes it possible to control the instrument by commands other than the built-in native SCPI commands. This feature allows the user to replace signal generators, e.g. from other manufacturers, with the R&S®SMBV100B without having to change the remote control code.This application note describes how to use the remote emulation feature in general. Furthermore, it describes in detail the remote emulation for each supported instrument, limitations of the individual emulations and the remaining differences between the emulated and the original commands.
30-Sep-2019 | AN-No. 1GP121
RF system noise contributions define receiver capabilities and sensitivity. The noise figure measures how the critical components affect the signal.
28-Jan-2022
Leaving aside the microwave generators, the present line of Rohde & Schwarz products comprisessignal generators up to 1 GHz (SMX, SMG), up to 2 GHz (SMH, SMGU), up to 3 GHz (SME, SMT) and up to 4.3 GHz (SMHU). For applications at higher frequencies, all signal generators can also be operated with an external passive frequency doubler. This extends the range of possible applications up to 8.6 GHz. Some degraded specs regarding level and modulation are described below. For people using the frequency range 3 to 6 GHz, the low priced combination SMT plus frequency doubler will mainly be interesting. Signal generator SMHU is useful for the frequency range up to 8.6 GHz. Especially the phase noise performance is excellent with this instrument. the required output signal. It should also be pointed out that the residual FM and the SSB phase noise will be 6 dB poorer as a result of frequency doubling.
20-Apr-1998 | AN-No. 1GPAN03
This document describes WLAN tests which rely on communication (signaling) between R&S®CMW and device under test (DUT) and on transmission of packet data over WLAN. On the R&S®CMW side the WLAN Signaling application is required, for some tests also the Data Application Unit (DAU).The test principles and the necessary settings are explained and background infor-mation is given. Step-by-step procedures are provided for the main configuration tasks.
08-Feb-2016 | AN-No. 1C107
IEEE 802.15.4 (ZigBee™) uses OQPSK with a half-sine pulse shaping filter as modulation. This application note describes how to generate and analyze ZigBee™ signals. Simple test signals can be setup with the free-of-charge simulation software R&S WinIQSIM™ and transferred to the vector signal generator R&S SMU200A. It describes how to setup the vector signal analyzer R&S FSQ with option R&S FSQ-K70 for ZigBee™ signal demodulation and how to analyze modulation quality such as error vector magnitude (EVM).
21-Jun-2007 | AN-No. RSI03
The topic of this application note is mobile phone measurements – in theory and in practice. It discusses measurements according to the most common standard in use today, GSM.The first, theoretical portion of this application note covers digital modulation and access methods in general. This is followed by an overview of the specific characteristics of the GSM standard as well as a summary of the most important mobile radio measurements.The second, practical portion of this application note covers some of these measurements in detail and runs through them step by step. These measurements can be performed by small groups in labs.The measurements and analysis of the results are intended to illustrate the theoretical portion of the application note and to deepen the reader's understanding.All measurements are performed using the R&S®CMW500 wideband radio communication tester and an off the shelf mobile phone.
22-Aug-2014 | AN-No. 1MA231
The R&S®Pulse Sequencer software together with the R&S®SMW200A vector signal generator offers a simple and easy way to simulate multi-emitter environments. It enables engineers to validate and verify the EW receiver performance.
13-Nov-2018
The use of Rohde & Schwarz device drivers under VEE software is not complicated. However, a number of factors are involved, the errors that occur are often difficult to diagnose. This application provides easy and detailed support for installation and troubleshooting using National Instruments or Agilent GPIB boards.
20-Dec-2012 | AN-No. 1MA035
Multichannel signal reception in parallel using digital downconverters in a monitoring receiver.
14-May-2014
Welcome to this introductory video show about the R&S® ZVA family of network analyzers. Network analysis is sometimes considered to be cumbersome and difficult to understand, a very offputting reputation for newcomers to network analyzers. To help you look at network analyzers in a different light, we have created this video series. We have intentionally refrained from explaining any theory in depth. Rather, we want to show you how to operate our analyzers for simple and useful applications. As well as just watching this video show, you can also use it as a guide and try yourself. All the operational steps shown only require a standard RF power amplifier which should be available in almost every lab. So, before we get properly started, we hope you enjoy this video show and much success in becoming familiar with network analysis in general, and our R&S products in particular.
13-Feb-2014 | AN-No. 1MA50
High-speed serial interfaces often transmit data with differential signaling and differential probes that can be used to access signal traces. In addition to differential inputs, these probes have a ground connection.
02-Nov-2022
Testing radar warning equipment in realistic scenarios is crucial to reliable field performance. This typically involved dedicated instruments or test systems. Commercial vector signal generators (VSG) such as the R&S®SMW200A from Rohde & Schwarz have become a very attractive alternative thanks to their increased available bandwidth and processing power.
13-Aug-2020
R&S®AdVISE is a visual inspection software to monitor different regions of interest (ROIs) in a video for visible and audible changes. It automates the process of visually monitoring equipment under test during a test sequence and therefore eliminates human inattention, ensures reproducible results and simplifies the test documentation. R&S®AdVISE offers the possibility to monitor up to 32 ROIs in one video with 12 different specialized ROI types for different kinds of events. That allows the user to apply R&S®AdVISE to all sorts of individual test setups.This application note explains how to setup R&S®AdVISE to monitor the temperature of an EUT by using an infrared camera.
14-Sep-2020 | AN-No. 1S008
Spurious emission search with spectrum analyzers is one of the most demanding measurements in the design, verification and production of RF and microwave devices. RF designers, especially in the aerospace & defense industry need to detect very low level spurs. Very narrow resolution bandwidths are required to measure with a low noise floor, hence increasing measurement time. Even working with very fast spectrum analyzers, a spur search may take several hours or even days.In this paper we will review the basics of spurious measurements and how the parameters used can affect the detection performance. A new technique as used in the R&S®FSW-K50 spurious measurement application which makes spurious search faster and easier to configure.
14-Jul-2017 | AN-No. 1EF97
Well-matched RF ports are a crucial aspect to any RF system. Matched ports, for example, protect amplifier output ports from reflected power overload. This undesired reflected power could destroy the whole amplifier. Matched ports also maximize power transmission, effectively extending the battery life of wireless products such as those made for the internet of things (IoT).
05-Mar-2020
For measurement settings below 10 mV/div, oscilloscopes typically reduce the measurement bandwidth in order to keep the trace noise as low as possible. The R&S®RTO is different: It offers the full bandwidth even for the most sensitive settings, and an A/D converter with more than 7 effective bits (ENOB) digitizes the signal.
13-Jul-2012
The R&S®SMA100A signal generator offers a remote emulation feature that makes it possible to control the instrument by commands other than the built-in native SCPI commands. This feature allows the user to replace signal generators, e.g. from other manufacturers, with the R&S®SMA100A without having to change the remote control code. This application note describes how to use the remote emulation feature in general. Furthermore, it describes in detail the remote emulation for each supported instrument, limitations of the individual emulations and the remaining differences between the emulated and the original commands.
17-Aug-2015 | AN-No. 1GP93
The following application note describes the function and operation of user menus for FSE Spectrum Analyzers including option Vector Signal Analysis (FSE-B7). For measurements according to the PCS 1900 standard for Mobile Stations user menus are provided, which perform settings on FSE for the different measurements required in the standard. The menu and the accompanying setups are stored on a floppy disk.
01-Nov-1996 | AN-No. 1EF22
In this application note the fundamental working principles of active antennas are asserted and it is described what makes them different compared to passive antennas. Furthermore the important parameters relating to active antennas are explained and typical system applications are discussed - including a comparison with passive antenna solutions and a chapter explicitly dealing with radio monitoring in the HF frequency range.
03-Feb-2016 | AN-No. 8GE02
Create and simulate detailed traffic situations for the verification of cellular V2X (C-V2X) connectivity.
18-Nov-2019
Many serial interfaces use Manchester or non-return-to-zero (NRZ) coding. Oscilloscopes typically offer dedicated software options for debugging and testing the communications interfaces for common standards such as I2C, UART or CAN. The R&S®RTx-K50 option expands the addressable range of interface standards by adding decoding capability for standardized and proprietary Manchester or NRZ coded buses. It allows customizable configuration of the protocol structure that has to be decoded.
19-Oct-2020
The R&S®SMB100A analog signal generator is the ideal calibration source for weather radar receivers due to its highly accurate output level.
25-Jan-2011
The Rohde & Schwarz R&S®CMU200 can be configured to perform packet data testing in a Mobile IP or Simple IP environment. This application note is intended as a guide to configuring the necessary Mobile IP or Simple IP network elements and R&S®CMU200 instrument for CDMA2000 1xEV-DO.
04-May-2007 | AN-No. 1CM64
Active, high-impedance probes can be connected to spectrum analyzers, providing a practical and highly precise measurement solution to overcome an otherwise cumbersome RF testing issue. This application note provides information on how to use oscilloscope probes in RF measurements using spectrum analyzers.
04-Jul-2023 | AN-No. 1EF116
This application note has been replaced by application note .
28-Aug-2009 | AN-No. 1MA45