243 Results
This additional option makes the R&S RTO and RTP oscilloscope to powerful multi-functional debug tools. Video, TDR/TDT, oscilloscopes, RTO, RTP Evaluate impedance and transmission loss of your signal traces with the RTO or RTP oscilloscope's TDR/TDT Analysis option.
17-Sep-2020 | Press Releases
Rohde & Schwarz offers bandwidth upgrades for selected oscilloscopes at no extra chargeBandwidth is the most important aspect of an oscilloscope. To support design engineers in current and future design challenges, Rohde & Schwarz is introducing an attractive promotion for selected oscilloscope models: when purchasing an R&S RTO2000 or R&S RTP, now customers can upgrade the bandwidth with no extra costs.
A sinus signal with i.e. 10 V peak-peak, frequency 1 MHz is applied. If I choose a vertical scale which is too small the peaks of the waveform are not displayed as they are out of range. Now I activate the digital filter in the “Vertical” menu à “Channel”. The frequency of the filter is also set to 1 MHz. Now even at very small vertical scales (i.e. 50 mV/div) the waveform is displayed completely, see screenshot. But the amplitude can not be correct. What goes wrong here?
RTP oscilloscopes can trigger on signals as small as 1/1000th of a vertical division thanks to digital triggering and adjustable hysteresis. 3 12 RTP, oscilloscope, scope, MSO, update rate, trigger, digital trigger RTP- see the difference. Trigger with highest sensitivity at full bandwidth.
Models: R&S®RTP-K28
Models: R&S®RTO-K23, R&S®RTP-K23
The RTP oscilloscope extends traditional de-embedding capabilities with flexible filter structures directly in the acquisition path. This allows waveform correction in real time. For the first time, users can trigger on corrected waveforms and focus on debugging the true device characteristics. 9 12 RTP, oscilloscope, scope, MSO, user interface, tool bar, toolbar RTP- see the difference.
Models: R&S®RTO-K22, R&S®RTP-K22
Models: R&S®RTO-K87, R&S®RTP-K87, R&S®RTO6-K87
This video is a throwback to the European Microwave Week 2024 and takes you on a quick run-through of wideband signal generation and analysis in the sub-THz frequency range, featuring the SFI wideband IF vector signal generator, FC330 H-band converters, and RTP oscilloscope. vector signal generator, FC330, H-band converters, RTP, oscilloscope The Potential of Sub-THz Frequencies with the FC330ST/SR
The RTP addresses this with an hardware-based math approach in the acquisition path, enabling for the first time triggering on math signals. 10 12 RTP, oscilloscope, scope, MSO, differential, differential signal, common mode, trigger RTP- see the difference. Benefit from differential signal and common mode beeing calculated in real-time.
Models: R&S®RTP-K89, R&S®RTO-K89, R&S®RTO6-K89
Models: R&S®RTO-K88, R&S®RTP-K88, R&S®RTO6-K88
Models: R&S®RTP-K25, R&S®RTO-K25, R&S®RTO6-K23
Models: R&S®RTO-K24, R&S®RTP-K24, R&S®RTO6-K24
Models: R&S®RTO-K86, R&S®RTP-K86, R&S®RTO6-K22
Volume Adjustment of the "BEEP"
FAQ - Decoding of SENT protocoll shows CRC errors
R&S Scope Suite - eMMC compliance test fails
Connection of DUT and Link partner with test fixture RT-ZF2
Letter of invitation Club of radio engineers
Oscilloscope, RTP High-performance oscilloscope, Energy measurement, Pulsed signal, math function Learn how to measure the energy of a pulsed sine wave signal with built-in advanced math functions of the R&S®RTP.
When I do RMS measurements and an offset is applied, the result changes. I could not see that effect on other scopes. What is wrong here?
Rohde & Schwarz Manual for Ethernet Compliance Test Fixture R&S®RT-ZF2. Describes the fixture boards and measurement preparations.
The RTP's Zone trigger allowes as the only oscilloscope in the world to isolate events in the time and the frequency domain. 12 12 RTP, oscilloscope, scope, MSO, Zone trigger, spectrum analysis, spectrogram, RF signal RTP- see the difference. Capture infrequent events in the spectrum.
Rohde & Schwarz Manual for frequency converter R&S®RT-ZF3.
Programming examples for oscilloscopes.
The Rohde & Schwarz manual describes the 1 MOhm high-impedance buffer amplifier for oscilloscopes with 50 ohm input impedance.
Rohde & Schwarz Manual for USB 2.0 Compliance Test Fixture Set R&S®RT-ZF1. Describes the fixture boards and measurement preparations.
Video, jitter, oscilloscopes Learn about the novel R&S approach to decomposite the individual jitter components with R&S®RTO or R&S®RTP oscilloscopes in order to gain more inside into your design.