Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
460 Results
RTO2000, waveform display, R&S®SmartGrid, complex measurements Use the R&S®SmartGrid function to configure the display. For complex measurement tasks where several screen displays are helpful, you can superposition windows in multiple tabs. All measurement diagrams have labeled scales so you can immediately read important signal characteristics.
This document is divided in two parts and starts with an introduction in AC-DC conversion principles in general. It will present the most common circuits used for different power levels. The switching mode power supply (SMPS) converter will be the main focus as they are used everywhere in the electronics. Especially the flyback converter design in different flavors are highlighted. Nevertheless, all measurements are also applicable for other SMPS converter designs operating at higher power levels.In the second part of this document, most relevant testing methods and procedures of an AC-DC converter are highlighted. For each testing section, a fundamental part will be upfront discussed and it is followed by a presentation of a suitable measurement method. In this second part, the device under test (DUT) is considered as black box device and thus the structure is similar. Therefore, the testing parts consists of methods related to input tests, output tests and a combination of both like efficiency. Of course, some test performed at the output of the converter are also relevant for DC-DC converter, e.g. the validation of the output ripple.
14-Nov-2022 | AN-No. 1SL387
This Application Note addresses signal measurements and analysis of automotive radars that are crucial during the development and verification stages.
10-Jun-2016 | AN-No. 1MA267
Oscilloscope bus debugging, RTO2000, bus debugging, UART, RS232, RS485 Let your Oscilloscope decode your UART/RS232/RS485 interfaces for you! So you can quickly understand the data and correlate the data content with the electrical signal.
RTO2000, user interface, toolbar, display, cockpit The advanced user interface enables clear orientation thanks to colour coding, as well as having a high-resolution capacitive touchscreen with gesture support. The toolbar at the top of the screen provides access to frequently used functions such as measurements, zoom and FFT.
Video, RTO2000, Oscilloscope, Power integrity test Today’s highly integrated electronic devices use smaller voltage levels and therefore require much smaller ripple levels on the power rails for reliable operation.
Webinar, RTO2000, Automotive Ethernet compliance testing This webinar presents details on the individual test cases of the compliance test and provides useful information on the required test setup.
The DUT operates in Test Mode 4 which is a PRBS sequence and it is exposed on a 125MHz disturber signal which comes out of theB6 signal generator which is integrated in the RTO6 oscilloscope. The ScopeSuite software provides a step by test foto guided test execution and reports the test results.
RTO2000, toolbar, measurement functions, fast access The toolbar at the top of the screen provides access to frequently used functions such as measurements, zoom and FFT. Configure measurement in a few seconds by simply activating the measurement setup in the toolbar and choosing the desired measurement function and source channel in the sidebar.
Sign up for latest Ethernet webinar “1000BASE-T1 automotive Ethernet compliance testing”
Generating models with a VNA and using these on an oscilloscope via the deembedding
23-May-2023 | AN-No. 1SL393
In this demo, Rohde & Schwarz and VIAVI Solutions in collaboration with Analog Devices are showcasing how advanced energy saving features such as microsleep DTx or discontinuous transmit on an O-RU platform save energy under real-world traffic loads - measured and validated through the R&S®RTO6 oscilloscope, the R&S®NGT power supply and the VIAVI TM500 O-RU tester.
Engineer's R&S®ESSENTIALS oscilloscope buyer`s guide: Master key features & ensure your oscilloscope meets your daily needs.
This results in minimal trigger jitter without postprocessing correction as well as high sensitivity that can be extended up to 16 bit in HD mode. 16-bit, low noise, RTO2000, high definition, precise measurement The unique digital trigger system from Rohde & Schwarz uses the sampling point of the A/D converter in the acquisition path so that the trigger system's input data is identical to the displayed
12-Nov-2020 | Press Releases | Automotive
Rohde & Schwarz supports the UNH-IOL in Automotive Ethernet testing services for OPEN Alliance TC9 test specificationTest and measurement specialist Rohde & Schwarz extends its support to the University of New Hampshire Interoperability Laboratory (UNH-IOL) with an extension to their compliance test services. As a result, UNH-IOL customers can now achieve compliance for automotive Ethernet cables and connectors (link segment) based on the OPEN Alliance TC9 working group test specification supporting both unshielded (UTP) and shielded twisted pair cables and connectors (STP).
This paper describes the characterization of aluminum electrolytic capacitors specifically used in AC-DC power converter applications. It will be discussed why this capacitor technology is critical regarding lifetime and why it cannot be substituted simply by any another capacitor technology. Different aging effects of the capacitor will be discussed. Usage of the capacitor in different AC-DC converter topologies will be presented. Simulation circuits will be used to analyze the capacitor in more detail before suitable measurements will be performed to demonstrate a real example of a switching-mode power supply (SMPS).After the introduction into the aluminum electrolytic capacitor basics and theory, this paper will also present all important and possible measurements of capacitor parameters, like capacitance, equivalent series resistance (ESR) and ripple current. This includes in-circuit measurement which can be performed with an oscilloscope. An LCR-bridge is used to obtain high accuracy measurements in addition. A comparison between the two measurement methods will be presented. Furthermore, the required measurement hardware for the in-circuit measurements and the bridge measurement will be discussed and presented.Lastly, two different lifetime calculation methods are presented and a real example is used to compare the advantages and disadvantages of the different methods.Thanks to Mr. Frank Puhane from Würth eiSos GmbH & Co. KG who provided me with all aluminum electrolytic capacitor samples including the prepared capacitor with build-in temperature sensors to perform all measurements. Furthermore, his great expertise was very beneficial and helpful to create this premium application note.
07-Feb-2023 | AN-No. 1SL388
Measuring the power supply noise rejection (PSNR) requires accurate generation and leveling of artificial, sinusoidal disturbances and measurement of resulting phase-noise and jitter impairments.
30-Sep-2020
Buy more - Save more | Customize your oscilloscope configuration and save big - Flyer Brochures and Data Sheets Flyer
This document provides the technical specifications of the R&S®RT-Zxx high voltage and current probes
Find out what it's like to launch a new product at Rohde & Schwarz! Our employees share their experiences.
In addition the RTO6 can be used to monitor the communication between the two automotive Ethernet devices and also check the frequency response and spectrum of the noise signal source coming from the SMW. 1000BASE-T1, Signal Quality Indicator (SQI) 1000BASE-T1 interoperability test
RTO2000, signal flow diagrams, dialog boxes, crosslinks Signal flow diagrams in the dialog boxes visualize the signal processing, making it easier to configure measurements. Crosslinks take you directly to logically related settings. Forward/back buttons help you navigate quickly between dialog boxes. Semi-transparent dialog boxes are an elegant way of keeping everything in view.
03-May-2023 | Press Releases | Test & measurement
Rohde & Schwarz demonstrates solutions for particle accelerators at IPAC’23 in VeniceAt IPAC’23 in Venice, Italy, Rohde & Schwarz demonstrates solutions that meet high precision particle accelerator requirements, address challenges in elementary particle research, particle therapy applications, material characterization, precise beam forming and monitoring as well as safe storage.
How to create your first remote control application
TC8 – OPEN Alliance - Flyer
Signal model based approach to joint jitter and noise decomposition - First published at DesignCon 2020 - White Paper
R&S VSE-K70x/FSx-K70x/FPx-K70x Vector Signal Analysis Application - Specifications
Verify and debug your PCI express protocols with PCIe test solutions by Rohde & Schwarz ► Get more information!
27-Oct-2021 | Press Releases | Test & measurement
Rohde & Schwarz once again live at productronica 2021 with T&M equipment for R&D, verification and productionRohde & Schwarz is presenting its solutions live at productronica 2021, the leading global trade show for electronics development and production. The focus is on T&M equipment for latest technologies including automotive radar, satellite communications, Wi-Fi 7 and 5G. High throughput and low cost are essential in production environments, and Rohde & Schwarz solutions support exactly these goals. Trade show visitors will find the following Rohde & Schwarz highlights and more in hall A1, booth 375 at Messe München.
From designing a test setup to performing accurate measurements
This application note discusses important aspects of double-pulse test setups as well as how to perform accurate measurements. Double-Pulse testing is a standard test-method.
22-Mar-2021 | AN-No. GFM347