74 Results
This document is an addendum to the "Options" section of the R&S®ZNA specifications (PD 5215.4652.22). It provides the technical specifications of the the following R&S®ZNA options: R&S®ZNA26-B10, R&S®ZNA43-B10, R&S®ZNA50-B10, R&S®ZNA67-B10.
Transmit/receive module and AESA radar testing
12-Jun-2025
優れたRF特性、独自の包括的なハードウェアアーキテクチャー、DUT指向の操作コンセプトを備えたR&S®ZNA ハイエンド・ベクトル・ネットワーク・アナライザを使えば、要件の厳しい測定への対応が容易になります。
Offering outstanding RF characteristics, a unique and comprehensive hardware architecture and a DUT oriented operation concept, the R&S®ZNA high-end vector network analyzer makes demanding measurements easier than ever before.
R&S®ZNA高端矢量网络分析仪具备出色的射频特性、独特多方位的硬件架构和以被测设备为中心的操作概念,能够更加轻松地执行高标准测量。
In combination with the time domain option R&S®ZNA-K2 and the extended time domain option R&S®ZNA-K20, the R&S®ZNA VNA offers a variety of signal integrity measurements.
Does the option ZNA-K1 (Spectrum analyzer mode) also work with the Millimeterwave Converters?
Ready for Spectrum Analysis The Rohde & Schwarz Vector Network Analyzer R&S®ZNA features a spectrum analyzer option (R&S®ZNA-K1). The Rohde & Schwarz Vector Network Analyzer R&S®ZNA features a spectrum analyzer option (R&S®ZNA-K1). The spectrum analyzer mode can be used at each of the four ports of the R&S®ZNA.
13-Oct-2020 | Press Releases
Rohde & Schwarz announces awards success with touch-operated analyzerThe R&S ZNA vector network analyzer is named the Test, Measurement & Inspection product of the year at the Electronics Industry Awards.
07-Apr-2021 | Press Releases
Rohde & Schwarz introduces new R&S ZNA vector network analyzers with up to 67 GHz frequency rangeThe R&S ZNA high-end vector network analyzer (VNA) now features models with 50 GHz and 67 GHz maximum frequencies. This opens up the VNA’s outstanding RF performance, unique hardware concept and innovative touch operation to new areas of application. Signal integrity measurements as well as A&D and 5G component and module characterization are main applications for the new analyzer models.
13-Jan-2022 | Press Releases
Rohde & Schwarz and FormFactor support the University of Texas at Austin in research on improved RF switches for 5G and 6GThe University of Texas at Austin, Rohde & Schwarz and FormFactor have collaborated to characterize a new technology for RF switches that improves battery life performance and supports higher bandwidths and switching speeds.
Nonlinear applications using Rohde & Schwarz vector network analyzers - Product Flyer
Noise figure is an important parameter that describes the noise contribution of an electronic device. A classical approach to measure the noise figure is to use a noise source which delivers two different input noise powers by switching between a “hot” and a “cold” state and a noise receiver
23-Dec-2021 | AN-No. 1SL378
This application note provides practical hints to accurately characterize and de-embed these lead-in and lead-out structures with R&S Vector Network Analyzers ZNA, ZNB, ZNBT and ZND.
19-Sep-2022 | AN-No. 1SL367
Describes all instrument functions and remote control commands, as well as measurement and programming examples.
The user is requested to move results from a Network Analyzer to the controller PC or to a network drive.
10-Oct-2024 | Press Releases
Patented antenna digital twin solution from Rohde & Schwarz and IMST optimizes automotive connectivityRohde & Schwarz, in collaboration with wireless communications engineering experts IMST GmbH, has developed a patented antenna digital twin solution, effectively addressing a multitude of challenges and delivering considerable benefits for vehicle manufacturers and their suppliers to optimize automotive connectivity. The solution combines measurements of the antenna characteristics with simulation of the electromagnetic wave propagation to optimize the antennas’ design and their position to ensure for example optimal WiFi coverage inside the vehicle.
Provides information on security issues when working with R&S®ZNA in secure areas.
ZNA/ZVA - Mounting of the converters ZCxxx
ZNA/ZNB: Export all mixed mode S-Parameters
I got a calibration kit with a sliding match standard. But there are no correction values for the NWA supplied.
How can I export the traces of a specific channel into one file, i.e. CSV?
Provides the information required to prepare the instrument for use and start working.
I perform a calibration with remote commands. With the command to start the calibration sweep with a short standard I get this error message. What is the problem?
When I export the time domain trace the stimulus values are in Hz, but not in seconds as shown on the screen. How can I get the export in time or distance?
This video presents how to perform measurements on frequency converting devices that have an embedded LO with an R&S®ZNA. This video presents how to perform measurements on frequency converting devices that have an embedded LO with an R&S®ZNA. The advantages of the R&S®ZNA solution for group delay measurements on such devices, including the LO tracking feature, and the dual LO concept are shown.
The instrument will then prompt the user, in a step-by-step process, to select and configure the desired measurements ZNA video, Network Analyzer, Vector Network Analyzer, ZNA, Test & Measurement, Intermodulation measurement, basic and scalar mixer measurement, group delay measurements Unique DUT centric operation
I want to use my ZNA as true differential signal generator for a constant CW signal.
30-May-2023 | Press Releases
Rohde & Schwarz and IEMN collaborate on 6G THz by bringing together electronic and photonic technologiesThe Institute of Electronics, Microelectronics and Nanotechnology (IEMN, Lille, France) and Rohde & Schwarz have expanded their collaboration to research THz communications that utilize photonic technologies. In a recent demonstration, IEMN reached a milestone when researchers achieved generated a 300 GHz bidirectional link over an outdoor distance of 645 m for use in future 6G backhauling scenarios. The R&S SMA100B microwave signal generator from Rohde & Schwarz was a crucial component in the performance test setup. The R&S SMA100B provides an ultra-low phase noise signal that helps accelerate THz communications research and development to ready it for industrialization.