Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1140 Results
3GPP TS36.141 defines conformance tests for EUTRA base stations (eNodeB). Release 14 added several tests, especially for enhanced License Assisted Accsess (eLAA).This application note describes how all required transmitter (Tx) tests (TS36.141 Chapter 6) can be performed quickly and easily by using signal and spectrum analyzers from Rohde & Schwarz. A few tests additionally require signal generators from Rohde & Schwarz.Examples illustrate the manual operation. A free software program enables and demonstrates remote operation.The LTE base station receiver (Rx) tests (TS36.141 Chapter 7) are described in Application Note 1MA195.The LTE base station performance (Px) tests (TS36.141 Chapter 8) are described in Application Note 1MA162.
11-May-2016 | AN-No. 1MA154
Analyzing RF pulses is a key aspect of pulsed radar applications, e.g. in air traffic control (ATC), maritime radar or scientific measurements of the ionosphere. Analyzing the modulation of the pulse is essential, because it contains important information to characterize the application. The R&S®RTO and R&S®RTP oscilloscopes can precisely trigger on and analyze RF pulses. This document describes the use of the R&S®RTO and R&S®RTP to demodulate RF pulses for further measurements.
13-Mar-2019
The following application note describes the function and operation of user menus for FSE Spectrum Analyzers including option Vector Signal Analysis (FSE-B7). For measurements according to the GSM standard user menus are provided, which perform settings on FSE for Base Station testing required in the standard. The menu and the accompanying setups are stored on a floppy disk. For operation of the menus firmware version 1.40 or higher is required. Option Vector Signal Analysis FSE-B7 has to be installed for the use of the application menu.
16-Jan-2002 | AN-No. 1EF23
The R&S®FSW signal and spectrum analyzer with the R&S®FSW-K160R realtime option and the R&S®FSW-K6 pulse measurement option is ideal for testing modern radars.
04-Jul-2013
With the wideband extension R&S®ESW-B1000, the R&S®ESW EMI test receiver allows never seen testing speed with up to 970 MHz of FFT bandwidth. External applications can now take advantage of the wide bandwidth. ESW firmware 3.20 adds a new method for exporting trace data from the instrument, regardless if the instrument is equipped with the wideband extension or not. SCPI commands allow live trace export of multiple traces simultaneously. This application note describes the use and applications of SCPI commands to request trace data of up to 4 traces simultaneously from the R&S®ESW receiver, even allowing CISPR detectors. The commands enable trace export while the instrument measures continuously and therefore theoretically enable infinite measurements.
25-Jul-2024 | AN-No. 1EE27
This application note helps the user to configure a Rohde & Schwarz vector signal generator for LTE FDD repeater conformance testing. It explains step by step how to set up the baseband signal for the various test cases defined in the 3GPP Technical Specification 36.143.The R&S®SMx vector signal generators provide predefined, LTE-conform test models and are therefore ideal for LTE repeater conformance testing. The test cases in TS 36.143 can be set up with a single instrument which provides all necessary test signals including the four specified repeater stimulus signals.
26-Apr-2013 | AN-No. 1GP85
The Electromagnetic Disturbance (EMD) emitted by Proximity-Integrated-Circuit-Cards (PICC) is a unwanted form of load modulation. This Application Note describes a method for measuring EMD during data transmission using vector signal analysis
19-Oct-2007 | AN-No. 1MA120
The signal purity of clock sources has a direct impact on system performance. To ensure proper operation, it is necessary to verify that the purity meets the design requirements.
30-Sep-2021
Wide range of set-top box tests in line with current DVB-xx standards using a variable, future-ready test system
13-Jul-2012
Today’s cars are highly integrated and interconnected. Up to 150 embedded electronic control units (ECUs) in a car secure a convenient and safe driving experience. Examples of ECUs include transmission control modules, ECUs for air conditioning systems, and even self-updating 5G-ready telematics control units.
06-Jul-2020
R&S®RTP, R&S®RTO, R&S®RTE, oscilloscopes, acquired waveform data, python How to work with acquired waveform data in Python using the R&S®RTP, R&S®RTO or R&S®RTE. Working with acquired waveform data in Python R&S®RTP, R&S®RTO, R&S®RTE, oscilloscopes, acquired waveform data, python How to work with acquired waveform data in Python using the R&S®RTP, R&S®RTO or R&S®RTE. Working with acquired waveform
12-Jan-2022
All electronic devices have capacitive or inductive parts that that generate inrush current when switched on. This is more than just a part of operations – it is a vital aspect and demands keen oversight. The R&S®NPA power analyzers are the right instrument for the job.
28-Mar-2024
In this day and age of internet of things, more and more devices are connected to the local network, making it even more difficult for the IT department to monitor them. Rohde & Schwarz instruments are also increasingly accessed via their LAN interface, which provides additional convenience features such as remote desktop, SMB file transfer or a web interface. To make it easier to monitor the use and status of instruments, some devices offer a software option, the Health and Utilization Monitoring Service (HUMS).HUMS can be accessed via SNMP and REST (HTTP) and provides all necessary information about the health status and utilization over time in many details.This application note describes how to access HUMS and what data is provided.
11-Jan-2021 | AN-No. GFM336
All types of information transmission, including the 'one-way' transmission used in broadcasting, involve feeding a radio frequency (RF) signal to an antenna. This is the essence of the most basic type of transmitter used to emit electromagnetic waves. In the real world, however, a transmitter used for broadcast applications, for example, is much more complex in terms of its functions and design. The different transmitter components must be carefully coordinated. There are many quality parameters that are critical in ensuring that a proper output signal is delivered. Rohde & Schwarz designed the R&S® ETL TV analyzer especially for broadcasting applications. The analyzer allows the measurement of the quality parameters that are relevant in analog and digital broadcasting. This Application Note describes the typical quality measurements performed during compliance testing of TV transmitters. The approach discussed here is based on the example of Rohde & Schwarz terrestrial transmitters for analog TV and DVB-T/H.
19-Sep-2007 | AN-No. 7BM67
Sequencer Software Tool
20-Feb-2015
This application note explains how to create screenshots of Rohde & Schwarz instruments using instrument drivers. The presented examples are written in C (LabWindows/CVI), C# programming language and LabVIEW. The examples are available at the instrument driver download site.
11-Dec-2009 | AN-No. 1MA160
Transformers are passive devices that are primarily used to convert or "transform" alternating current (AC) from one voltage level to another. One very common application of transformers is in AC to DC power supplies, in which mains voltage is stepped down before being rectified and filtered to produce DC. There are numerous other applications for transformers, such as providing electrical isolation or for impedance matching.This educational note provides a brief technical introduction to measurements made on the types of transformers used in electronics. These transformers are typically physically small, work on relatively low voltages or powers, and are used for “indoor” applications. Although many of the testing concepts described below also apply to the larger, higher-power "outdoor" transformers used for electrical power distribution, the specific tests and test procedures for these types of transformers are often specified by standards bodies such as the IEEE and may differ substantially from the types of measurements described here.Read this educational note and dive into the discussion about the six most important transformer measurements: turns ratio, mutual inductance, phase angle, primary and secondary inductance, leakage inductance, and interwinding capacitance.
28-Feb-2024
In high-speed digital measurement applications, test fixtures are commonly used to connect devices under test to measurement equipment. Characterization, and analysis in the time and frequency domains that accounts for various constraints helps to remove the influence of these fixtures.
23-May-2023 | AN-No. 1SL393
In addition to frequency, power and long-term stability, short-term stability or its equivalent, phase noise, is an important characteristic of signal sources. For example, the phase noise of conversion oscillators of receivers obtained in the presence of a strong signal determines adjacent-channel sensitivity. In the case of transmitters, the phase noise of the oscillator together with the modulator characteristics is responsible for the power generated in adjacent channels. The phase noise of oscillators or synthesizers and the relevant measurements therefore play an important role in radio transmission systems.
16-Jan-2002 | AN-No. 1EF16
The vector signal generators and GNSS simulators R&S®SMW200A and R&S®SMBV100B are remote-controllable in realtime and can therefore be implemented into a dynamic HIL environment. The HIL simulator can dictate position coordinates, kinetic parameters, and vehicle attitude information based upon which the R&S® GNSS simulator updates the simulated receiver movement in realtime. This application note presents background information and details about operating a R&S® GNSS simulator in HIL applications.
14-Apr-2020 | AN-No. 1GP102
Harmonic load pull measurements explore potential device efficiency to find the best design topology.
17-Apr-2023
LTE is under continuous development. Release 10 (LTE-Advanced) introduced carrier aggregation (CA) as the primary enhancement. Releases 11 and 12 add several new components to LTE. Some are enhancements to existing features (such as improvements to CA), while others are completely new concepts, such as coordinated multipoint (CoMP).This application note summarizes the Rohde & Schwarz test solutions for LTE-Advanced according to Releases 11 and 12 using vector signal generators, signal and spectrum analyzers and the wideband radio communication tester.
14-Jul-2016 | AN-No. 1MA272
Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many viewers. A single instrument, the R&S®ETL TV analyzer, performs all required ISDB-T transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commissioning and preventive maintenance.
13-May-2013 | AN-No. 7BM103
The strict requirement of network synchronization is as old as digital cellular mobile networks. As soon as cells have a neighbor relationship, network synchronization is mandatory in both the frequency and time domains in order to ensure UE QoE and performance (Handover, MIMO, data throughput, etc.). This educational note describes how 5G NR with its extremely flexible specifications is affected by these synchronization requirements, and how it can be measured?
17-Aug-2021 | AN-No. 8NT05
Integration of instruments with an Ethernet interface, such as the R&S®OSP open switch and control platform, into a pure GPIB bus system.
02-Aug-2010
Power amplifiers in digital TDMA mobile phones are fed with current only during the active slot to save power. Using conventional measuring equipment, the noise figure, an important parameter in power amplifiers, can only be determined with the amplifier in continuous operation. However, continuous operation can lead to amplifier overload and produce distorted results. Now there is a convenient way of determining the noise figure of amplifiers with pulsed power supply: using a Spectrum Analyzer (FSP or FSE or FSIQ or ESI), Noise Measurement Software FS-K3 and a function or pulse generator.
19-Dec-2000 | AN-No. 1MA32
This application note explains how to synchronize the signals from multiple R&S®SMBV100A vector signal generators in time.The synchronization of the instruments is based on a master-slave principle where one R&S®SMBV100A acts as master and supplies all necessary synchronization signals to the other instruments (slaves). The setup is simple and provides highly synchronized test signals. Time synchronous signals are needed in several applications. The master-slave setup is ideal for basic MIMO tests, certain GNSS test scenarios and WLAN IEEE 802.11ac non-contiguous channel generation. Furthermore, synchronous baseband signals are the basis for generating phase coherent RF signals with the R&S®SMBV100A.
09-Jul-2013 | AN-No. 1GP84
The R&S®RF Ports Alignment Software together with the R&S®SMW-K545 option provides a standard and tailored solution for calibrating and aligning the amplitude, group delay and phase between the RF ports of multiple coupled dual-path or single-path R&S®SMW200A vector signal generators. In addition, the R&S®Pulse Sequencer Software supports users to calculate the required signals for interferometric direction finding (DF) test cases. The R&S®SMW200A signal generator hardware together with the aforementioned software packages enables precise angle of arrival (AoA) simulation for testing the true performance of interferometric direction finders or emitter location systems.
08-Jul-2022
Rohde & Schwarz signal generators can generate standard-compliant WLAN IEEE 802.11ax signals for high efficiency (HE) receiver testing.This application note helps to choose the right generator test solutions and explains step-by-step how to generate 802.11ax SISO and MIMO signals. Measurements, such as EVM, are presented to illustrate the signal performance. Furthermore, this document shows how to test 802.11ax receiver specifications and the newly introduced HE trigger-based PPDU specifications according to the IEEE P802.11ax/D1.3 specification draft.
16-Aug-2017 | AN-No. 1GP115