Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
531 Results
RTO2000, deep memory, CAN Bus data, decoding, automotive Discover how Rohde and Schwarz oscilloscpes with deep memory can record over a minute of CAN bus data, as displayed on an R&S®RTO.
RTO2000, repetitive measurements, instrument setup The R&S®RTO can save instrument setups for repetitive measurements. Each instrument setup is saved along with a screenshot of the most recent oscilloscope display. To later select a desired instrument setup, simply scroll through the screenshots to find the right configuration.
Read this application card to learn more about what the 10BASE-T1S Ethernet compliance test offers and how it ensures reliable operation and functionality.
15-May-2020
RTO2000, signal analysis, detailed analysis, deep toolset R&S®RTO oscilloscopes offer over 90 measurement functions. The functions are organized by type into amplitude and time measurements, jitter, eye, histogram and spectral measurements. Statistics, histograms, and trend and track functions facilitate detailed analysis of the measurement results.
R&S RTO2000: Documentation at the press of a button R&S®RTO oscilloscopes help you document measurements, including printing and saving screenshots of the screen content, easy to read signal characteristics thanks to clear grid annotations and color-coded labels to highlight anomalies in the diagram.
Take your projects to the next level. Customize an R&S®RTO6 or R&S®RTP oscilloscope configuration to fit your specific needs and enjoy big savings. ▶ Learn more!
RTO2000, SPI, bus decoding, serial protocols R&S®RTO oscilloscopes offer a variety of tools for serial interface analysis. The configuration for any given protocol is accomplished in just a few steps starting from the app cockpit. Just select the bus you want to decode, configure the bus settings and set the reference levels to 50 %.
Video, RTO2000, Oscilloscope, Capturing of intermittent RF signals with the Zone Trigger This video demonstrates this unique capability of the R&S®RTO on the example of a frequency hopping signal.
This video shows how the R&S®RTO oscilloscope with its vector signal explorer (VSE) software can be used to analyze wide band pulsed RF signals in terms of frequency, phase, amplitude and timing. Video, RTO2000, Oscilloscope, Analysis of wideband pulse signals This video demonstrates this unique capability of the R&S®RTO on the example of a frequency hopping signa
The Rohde & Schwarz option K65, SpaceWire trigger & decode, for R&S®RTE and R&S®RTO offers triggering and decoding of SpaceWire protocol communication. Video, RTO2000, Oscilloscope, SpaceWire Triggering & Decoding The Rohde & Schwarz option K65, SpaceWire trigger & decode, for R&S®RTE and R&S®RTO offers triggering and decoding of SpaceWire protocol communication.
R&S RT-Zxx Standard Probes - Specifications
R&S RTO6 – Serial bus trigger and decode with R&S RTO6 oscilloscopes - Application Brochure
In pursuit of developing standardized testing methodology in electronics development, the HORYZN team at the Technical University of Munich integrated the R&S®RTO (with the R&S®RT-ZPR20 power rail probe) from Rohde & Schwarz into their prototyping design-loop and workflow.
The high definition mode (HD mode) activates configurable lowpass filtering of the signal after the A/D converter, increasing the vertical resolution to up to 16 bit. 16-bit, low noise, RTO2000, high definition, precise measurement The low-noise frontend and 10 GHz single-core A/D converter are the foundation for the extraordinarily high measurement accuracy and dynamic range of the R&S®RTO oscilloscopes
Rohde & Schwarz presented the R&S®RTO oscilloscopes at the European Microwave Week 2011. The R&S®RTO combines excellent signal fidelity, high acquisition rate and the world's first realtime digital trigger system with a compact device format. A new standard in user friendliness is offered by the R&S®RTO's remarkably simple touchscreen operation.
R&S®RTO6 versus Keysight MXR Series - Comparison Sheet Brochures and Data Sheets
R&S®RTO6 Instant insight meets in-depth information - Fact Sheet Brochures and Data Sheets
R&S®RTO6 Straightforward workflows with streamlined user interface - Fact sheet Brochures and Data Sheets
R&S®RTO6 オシロスコープ versus Keysight MXR シリーズ - Comparison Sheet Brochures and Data Sheets
R&S®RTO6 Oscilloscope versus Lecroy WavePro HD - Comparison Sheet Brochures and Data Sheets
The R&S®RTE and R&S®RTO oscilloscopes can measure currents down to 100 uA using their low noise and high-sensitivity current probe. Video, RTO2000, Oscilloscope, Measurement of very small currents The R&S®RTE and R&S®RTO oscilloscopes can measure currents down to 100 uA using their low noise and high-sensitivity current probe.
UI Comparison: R&S®RTO6 versus Keysight Infiniium EXR/MXR - Comp sheet - Comparison Sheet Brochures and Data Sheets
UI comparison: R&S®RTO6 versus Tektronix MSO 5/6/6 B - Comparison Sheet Brochures and Data Sheets
Defining masks is easy and flexible with the R&S®RTO. Video, RTO2000, Oscilloscope, Industry-leading mask test Defining masks is easy and flexible with the R&S®RTO.
The many unique R&S®RTO oscilloscope features enable you to make better and faster power measurements. RTO2000, spectrum analysis, precise measurements, power measurements Whether you are working with a motor drive, SMPS or power rails, making fast and precise power measurements can be challenging.
This white paper provides an introduction to the signal quality parameter effective number of bits (ENOB) and shows measured values for R&S®RTO6 oscilloscopes.
Signal Configuration Learn about key advantages of the PAM-N analysis option on the R&S RTP & RTO6 oscilloscopes. Start with the Signal Configurator. The PAM-N Analysis option enables the measurements and detailed characterization of PAM signals (PAM order of 2-8) with the R&S RTP and RTO oscilloscopes.
This application note aims to explain test procedures and characterization of the relevant parameters for active phased array antennas.
04-Jul-2016 | AN-No. 1MA248
Video, RTO2000, Oscilloscope, Testing conducted emission in the R&D lab This video shows how the powerful spectrum analysis features in the R&S®RTO oscilloscope can be used to verify conducted emission levels relative to the requirements during development thereby ensuring passing results in the compliance laboratory.