Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1133 Results
Radar equipment is always designed to work at the technologically feasible limits. Therefore the true performance of radar equipment can only be measured with the most accurate and reliable pulsed test signals. The R&S®SMA100B analog RF and microwave signal generator with its high-quality pulse modulator provides narrow pulse modulation. Thanks to a powerful closed-loop level control concept also for narrow pulses, outstanding level accuracy and repeatability is now available for pulse widths starting at 100 ns.
30-May-2017
Speed up development, verify best performance and start up series production with confidence. Doherty designs achieve high efficiency, greater linearity and increased output power. Get deep insight into your design with a dual-path, precisely synchronized source driving the Doherty amplifier and improve your yield.
12-Jul-2018
NGM200, NGL200 The R&S®NGL200 and R&S®NGM200 can simulate battery cells when testing battery management systems and replace far more expensive dedicated battery simulators. Testing battery management systems with Rohde & Schwarz power supplies NGM200, NGL200 The R&S®NGL200 and R&S®NGM200 can simulate battery cells when testing battery management systems and replace far more expensive dedicated battery
08-Jun-2020
This application note describes how to measure the antenna pattern of a mm-Wave device in the R&S®ATS1000 shielded chamber. This includes the required calibration of the measurement setup and a possible near field to far field transformation when measuring larger devices.
28-May-2018 | AN-No. 1MA304
Multiple antenna systems, known as MIMO systems, form an essential part of today’s wireless communications standards. The multi-antenna technology efficiently boosts the data throughput without requiring additional bandwidth or transmit power and has thus become a key technology. Rohde & Schwarz offers compact and versatile MIMO test solutions with realtime fading including simulation of channel correlations.This application note explains how to set up Rohde & Schwarz signal generators for 2x2, 4x2 and 2x4 MIMO tests with a focus on signal routing, synchronization of the generators, and leveling. Please note that there is a successor application note available: 1GP97. It explains how to use the R&S®SMW200A vector signal generator for testing higher order MIMO systems such as 3x3 and 4x4.
14-Oct-2009 | AN-No. 1GP51
Using option ZVR-B4 (Frequency Converting Measurements), a ZVR Vector Network Analyzer can be used for measurements on frequency converting devices such as mixers and amplifiers. Using the ZVR's ARBITRARY mode, the source and receiver frequency ranges of the ZVR's generator and receiver, plus for two external signal generators, can be defined independently. As a result, mixer and intermodulation products such as conversion loss or sampling mixers, can all be measured. Used together with option ZVR-B6 (Reference Channel Ports), group delay measurements can also be made on frequency converting devices.
19-Jan-1999 | AN-No. 1EZ47
Spectrum scans are beneficial for many use-cases such as troubleshooting, interference detection and interference hunting, or verification tasks like scheduler verification or other engineering tasks. A time-gated spectrum scan, which is a power spectrum scan which applies a time gate on uplink/downlink slots/symbols and/or the guard period reveals even more details in uplink/downlink or guard period power spectrum. This allows to focus on the uplink / downlink or guard period power spectrum in 5G NR TDD networks. This educational note explains use cases for spectrum measurements, the complexity in 5G TDD and its technology basics, and which problems can be solved with the described solution. The software used is R&S®ROMES4 together with a R&S®TSMx6 drive and walk test scanner.
21-Sep-2023 | AN-No. 8NT08
Simultaneously measure various current levels from μA to A in all phases of IoT device activity – from sleep to receive and transmit mode
01-Oct-2019
eCall is deployed in Europe and is required by law in new cars as of March 2018. Next generation eCall (NG eCall) is built on LTE and 5G.
06-Jun-2018
Power Added Efficiency (PAE) is a key parameter for the characterization of an amplifier.This application notes introduces two alternative methods how to do the Power Added Efficiency measurement. The first one is based on the R&S ZNB vector network analyzer (VNA) measurement function. Alternatively to this, the PAE tracer macro is introduced. This macro offers to make the PAE at an user selected compression point of the amplifier versus frequency. The PAE tracer macro is provided together with this application note.
22-May-2013 | AN-No. 1EZ64
This Application Note describes characterization of devices used in radar systems with pulsed signals. The emphasis is on measurements using vector network analyzers (VNAs), signal generators, vector signal generators and spectrum analyzers.
18-Jan-2008 | AN-No. 1MA124
This application Note is based on CMW500, SMBV100B and Vector CANoe.Car2x Software and guides to how to simulate the specific Cellular Vehicle-to-Everything (C-V2X) wireless environment in respect to road transport scenarios and transmitted messages around the Device Under Test (DUT) like a Telematics Control Unit (TCU). It shows how to verify and validate the C-V2X application of the DUT in laboratory environment. The virtual simulation scenario is not limited to the requirements of CSAE53-2017 specification, and it could be modified by user according to this operating guide with CANoe.Vehicle-to-everything (V2X) is a new generation of information and communications technologies that connect vehicles to everything. The objective of V2X is to increase road safety and manage traffic efficiently.C-V2X is designed to offer low-latency vehicle-to-vehicle (V2V), vehicle-to-roadside infrastructure (V2I) and vehicle-to-pedestrian (V2P) communications services to add a new dimension to future advanced driver assistance systems (ADAS). C-V2X as one communications standard defined by 3GPP in Release 14 uses LTE technology as the physical interface for communications. The standard describes two types of communications. The vehicle-to-network (V2N) communications type, exploits the cellular Uu interface, uses traditional cellular link to enable cloud services to be integrated into end-to-end solutions, e.g. to allow road and traffic information for a given area to be distributed to the vehicles.The second type is referred to as direct or PC5/Sidelink (V2V, V2I, V2P) communications, where data transmission takes place over the PC5 interface. In that type, C-V2X does not necessarily require a cellular network infrastructure. It can operate without a SIM and without network assistance and uses GNSS as its primary source for time synchronization.Verifying system functionality and performance exclusively by field testing in a real-world environment can be time-consuming, costly and very challenging. Requirements regarding functionality, and consequently the required assistance functions, are constantly changing. Due to this fact, test solutions are needed during the development and introduction phase to verify compliance with the standards. The PC5 direct communications type allows exchange of time sensitive and safety relevant information. Using a mobile communication tester like the R&S® CMW500 together with a C-V2X scenario simulation tool delivers reproducible test scenarios. This is essential for the standardization of verification processes for C-V2X in order to obtain reliable and comparable results, and it helps to demonstrate that end-to-end functionality between two C-V2X devices from different vendors works properly.
02-Jun-2021 | AN-No. GFM341
Frequency allocation plans are under discussion in the US and Europe to open the lower C band for 5G applications. This portion of the spectrum provides 5G with more bandwidth than conventional lower mobile frequency bands and is contiguous while the C band is actually in use for satellite downlinks to satellite earth stations (SES).
18-Mar-2019
This Application Note provides an overview of the Bit Error Rate (BER) test capabilities of the Universal Radiocommunication Tester CMU300 on GSM / EDGE Base Stations. It includes information about measurement principles, the supported test environment and channels, CMU settings, operation, and ordering information.
15-Jan-2002 | AN-No. 1CM32
This white paper provides a brief technology introduction on the 802.11ac amendment to the successful 802.11-2007 standard. 802.11ac provides mechanisms to increase throughput and user experience of existing WLAN and will build on 802.11n-2009.
23-May-2012 | AN-No. 1MA192
When measuring the performance of 802.11 wireless LAN compatible receivers, Packet Error Rate (PER) tests are the method of choice today. This application note describes a simple way to conduct PER tests using signal generators on any 802.11 device, independent of their physical layer design (11b, 11a or 11g). The application software works with standard Windows™ drivers on any card independent of manufacturer. No additional hardware specific software is needed. Easy setup of the source signal is included with direct upload to an SMIQ or AMIQ.
09-Jan-2012 | AN-No. 1GP56
This Application tests whether a multi-mode mobile phone supporting both GSM and IS136 has registered onto a GSM network, or an 136 network. The test set-up requires a CRTx to provide the GSM BCCH carrier, and a CMU200 to provide the IS136 DCCH carrier.
07-Mar-2003 | AN-No. 1CM31
Analyzing RF pulses is a key aspect of pulsed radar applications, e.g. in air traffic control (ATC), maritime radar or scientific measurements of the ionosphere. Analyzing the envelope and the modulation of the pulse is essential, because they contain important information to characterize the application. The R&S®RTO and R&S®RTP oscilloscopes are capable of triggering precisely on a pulse as a prerequisite for time domain and frequency domain analysis. This document describes the use of the R&S®RTO and R&S®RTP to trigger exactly on pulses in preparation for further in-depth measurements such as RF pulse measurements on an ATC signal.
13-Mar-2019
More frequency bands and larger dynamic ranges increase the number of test points required in characterization and production of the latest RF frontends (RFFE). Actively managing test time and cost while maintaining quality is more important than ever before.
08-Jun-2020
A lack of lip synchronicity is an effect that can severely impair the quality of TV reception. With modern digital signal processing, this audio-to-video delay occurs much more often than in earlier times when analog signal generation was used. The total delay can reach several hundred milliseconds, which is immediately noticeable on a TV home receiver. To prevent such impair-ments, the audio-to-video delay must be measured.
27-Aug-2002 | AN-No. 7BM44
This application note is intended as a guide to configuring the R&S®CMU200 instrument for CDMA2000 1xEV-DO / 1xRTT Hybrid Mode testing.
01-Oct-2007 | AN-No. 1CM65
The R&S spectrum analyzers and signal analyzers offer an additional equalizer filter in the Vector Signal Analysis Application Firmware R&S FSQ-K70/FSx-B73, which is a powerful tool for measurement and analysis of vector-modulated signals. This application note describes the functionality of the equalizer filter and how to set the filter parameter manually in an accurate and fast way.
06-Feb-2009 | AN-No. 1EF61
The Rohde & Schwarz R&S®CMU200 can be configured to perform packet data testing in a Mobile IP or Simple IP environment. This application note is intended as a guide to configuring the necessary Mobile IP or Simple IP network elements and R&S®CMU200 instrument for CDMA2000 1xEV-DO.
04-May-2007 | AN-No. 1CM64
Measuring and optimizing the characteristics of individual elements within an antenna array for beamforming performance of Qualcomm 5G mmWave modems SDX50 and SDX55.
25-Feb-2020
Active, high-impedance probes can be connected to spectrum analyzers, providing a practical and highly precise measurement solution to overcome an otherwise cumbersome RF testing issue. This application note provides information on how to use oscilloscope probes in RF measurements using spectrum analyzers.
04-Jul-2023 | AN-No. 1EF116
Ensures compliance of IEEE 802.3bj/by/cd/ck cables with fast automation and easy testing.
04-Oct-2022
This application note describes Methods of Implementations (MOI) for precise, fast and error-free compliance testing of high-speed backplanes and direct attach copper cables (DAC) according to IEEE 802.3bj, IEEE 802.3by, IEEE 802.3cd and IEEE 802.3ck, based on 25 Gb/s, 50 Gb/s and 100 Gb/s signaling per lane with vector network analyzers from Rohde & Schwarz.
07-Apr-2021 | AN-No. GFM356
The FLO in MediaFLO stands for 'forward link only'. MediaFLO technology covers transmission of files and multimedia content to handheld devices. The FLO device minimum performance specification (MPS) was created to ensure that FLO receivers can receive a FLO service that fulfils the compatibility guidelines of the FLO air interface specification. This Application Note shows how the Broadcast Test System R&S SFU from Rohde & Schwarz can be used to generate all test scenarios required by the minimum performance specification.
31-Aug-2006 | AN-No. 7BM62
The validated UWB PHY test suite for the R&S®CMP200 radio communication tester simplifies FiRa™ Consortium PHY conformance testing.
21-Jun-2022