background
RS-Logo RS-Logo Mini
Choose Location
Customer portal
Back
Aerospace and defense
Back Overview Aerospace and defense
Air
Land
Sea
Cyber
Space
Multi-domain
Industry partners
Automotive testing
Back Overview Automotive testing
Automotive connectivity and infotainment
Automotive EMC and full-vehicle antenna testing
Automotive radar
Electric drivetrain component testing
In-vehicle networks and ECU testing
Broadcast and media
Back Overview Broadcast and media
Broadcast distribution
Media technologies
Critical infrastructure
Back Overview Critical infrastructure Air navigation testing Cellular network investigations Civil air traffic control Countering drones
Mobile network testing
Networks and cybersecurity Security screening Spectrum monitoring
Electronics testing
Back Overview Electronics testing Consumer electronics testing
Digital design testing
EMC testing
High-speed digital interface testing
Medical device testing
Power electronics testing
RF and microwave components
Networks and cybersecurity
Back Overview Networks and cybersecurity Cybersecurity for aerospace and defense Cybersecurity for the financial industry R&S®ComSec Secure networks and cybersecurity for public authorities Secure networks for commercial business Secure networks for healthcare
Research and education
Back Overview Research and education 6G research Antenna research Material characterization Particle acceleration Quantum technology Teaching lab solutions
Satellite testing
Back Overview Satellite testing 5G NTN satellite testing Satellite ground station testing and operation Satellite in-orbit testing Satellite payload and bus testing Satellite user terminal testing
Security
Back Overview Security
Governmental security
Networks and cybersecurity
Security screening
Wireless communications testing
Back Overview Wireless communications testing EMC and regulatory testing
IoT / M2M testing
Mobile device testing
Mobile network infrastructure testing
Wireless standards
Back
Test and measurement
Back Overview Test and measurement
Amplifiers
Analyzers
Antenna test systems and OTA chambers
Automotive radar testers
EMC test equipment
Mobile network testing
Oscilloscopes
Power supplies and source measure units
R&S®ESSENTIALS test equipment
RF and microwave power meters
Signal generators
System components
Wireless device testers and systems
Broadcast and Media
Back Overview Broadcast and Media
Broadcast Distribution
Media Technologies
Aerospace | Defense | Security
Back Overview Aerospace | Defense | Security
Radiomonitoring
Secure communications
Security scanner
Cybersecurity
Back Overview Cybersecurity Endpoint security Management systems Network encryptors Secure web browser
Back
Service
Back Overview Service Cybersecurity services Calibration services Extended warranty & service contracts Obsolescence management On-site services Repair services Service level agreement Service partner program
Support Service & support request
Back Knowledge+ Downloads Videos Webinars Local Resources R&S Norway Research projects Technology Academy
Technology fundamentals
Back Overview Technology fundamentals Antennas for mobile and stationary use Hopper signals Monitoring receiver skills Radio direction finding techniques Signal analysis methods
Back
About Rohde & Schwarz
Back Overview About Rohde & Schwarz Compliance High vertical integration Sustainability
Rohde & Schwarz Norway
News & media
Back Overview News & media NEWS Magazine Press & media contacts Press room
R&S Magazine
Back Overview R&S Magazine From insight to impact Podcast Behind Innovation Artificial Intelligence Protection of critical infrastructures Tradition of innovation Sovereignty 6G: vision or reality?
Seminars Trade shows & events
Back Overview Jobs Professionals College and university students High school students Culture Events Contact
  • Applications

Search Application Notes & Cards

Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.

Filter by Content
  • Products 928
  • Solutions 856
  • Technologies 62
  • Service 23
  • News 745
  • Jobs 642
Download Center 6902

Download Center

Find the latest firmware, software, drivers, manuals, brochures. specifications and technical literature in our Download Center

1147 Results

Relevance

Remote Emulation Modes with R&S Signal Generators

Signal generators are often used in automated test environment applications. The replacement of those instruments, e.g., due to malfunction or standard replacement procedures requires special care to be taken in consideration. Replacement of those instruments requires compabitiblity between the replacement and the replaced device in at least the electrical and remote-control features. This application note describes in detail how to use the emulation modes of the R&S® series SMA100A, SMB100A, SMF100A signal generators.

24-Jun-2008 | AN-No. 1GP71

Demonstration of BER Test with AMIQ controlled by WinIQSim

A test setup is described for easy demonstration of the Bit Error Rate Test (BERT) function of AMIQ/AMIQ-B1. The test setup contains I/Q Modulation Generator AMIQ/AMIQ-B1 controlled by I/Q Simulation Software WinIQSIM, Vector Signal Generator SMIQ and Spectrum/Vector Signal Analyzer FSE/FSE-B7. The FSE with FSE-B7 is used as online FSK demodulator (setting: Analog demodulation, FM Signal, DC coupling, Real Time On) to demodulate the SMIQ RF signal FSK-modulated by PRBS data. The AMIQ is controlled by WinIQSIM software and receives the demodulated AF output signal from the FSE for BER testing.

29-Sep-1998 | AN-No. 1MA16

LTE UE receiver performance measurements

LTE user equipment (UE) receiver performance has significant impact to cellular radio network coverage and capacity. It determines the maximum data throughput across the air interface between the LTE base station (eNB, evolved node B) and the mobile network subscriber UE, thus it determines the total capacity across the air interface. Therefore, it is one of the most important measurements to verify the actual receiver performance of individual devices, and a key metric to compare different devices, in particular.This paper shall give an introduction to receiver performance measurements and discusses the measurement metrics as well as the challenges of over the air (OTA) measurements.

31-Aug-2017 | AN-No. 1ST001

Power and Modulation Measurements on VHF Transmitters Example: Rohde & Schwarz VHF-FM Transmitter SU115

A whole series of measurements has to be carried out for drafting an acceptance test report for a VHF sound broadcasting transmitter in compliance with ARD Specifications 5/3.1 (= TL 5820-3018 of the Deutsche Bundespost). As in most cases parameters like transmitter output power, frequency stability, spurious modulation, etc. have to be measured in the two stereo channels of the transmitter separately and at different modulation frequencies and frequency deviation, manual-controlled measurements are very time-consuming. In addition, a great variety of test equipment eg AF generator, stereodecoder, level meter, etc. is required for the measurements. FMAB with option FMA-B4 (AM/FM Calibrator / AF Generator) is ideally suitable for these measurements on VHF sound broadcasting receivers. The internal AF generator provides the signals required for the left and the right stereo channel. The MPX signal from the VHF transmitter is decoded by the built-in stereodecoder. As a result many of the tests and measurements required for the acceptance of VHF sound broadcasting receivers can be carried out without any additional test equipment being required. To give an example, a test program running under the graphics user interface Microsoft Windows has been developed for carrying out automatic power and modulation measurements via a PC.

04-Jun-1998 | AN-No. 1EF09

Generating narrow pulses with highest level accuracy and repeatability with the R&S®SMA100B

Radar equipment is always designed to work at the technologically feasible limits. Therefore the true performance of radar equipment can only be measured with the most accurate and reliable pulsed test signals. The R&S®SMA100B analog RF and microwave signal generator with its high-quality pulse modulator provides narrow pulse modulation. Thanks to a powerful closed-loop level control concept also for narrow pulses, outstanding level accuracy and repeatability is now available for pulse widths starting at 100 ns.

30-May-2017

Easy Analysis and Precise Optimization of ATSC or ATSC Mobile DTV Single-Frequency Networks

Keeping an ATSC (or ATSC Mobile DTV) single-frequency network (SFN) running smoothly not only requires that every single TV transmitter functions properly – the RF performance criteria echo pattern and frequency deviation also have to be strictly complied with. The R&S®ETL TV analyzer enables operators to check these crucial RF parameters at a glance with unmatched precision. The patented implementation achieves an echo delay resolution of one nanosecond, which is nearly a hundred times higher than in conventional approaches. This allows more precise control and adjustments of the several transmitters within the ATSC (or ATSC Mobile DTV) SFN and thus helps to ensure excellent coverage for the receivers.

21-Apr-2010 | AN-No. 7BM75

Testing battery management systems with Rohde & Schwarz power supplies

NGM200, NGL200 The R&S®NGL200 and R&S®NGM200 can simulate battery cells when testing battery management systems and replace far more expensive dedicated battery simulators. Testing battery management systems with Rohde & Schwarz power supplies NGM200, NGL200 The R&S®NGL200 and R&S®NGM200 can simulate battery cells when testing battery management systems and replace far more expensive dedicated battery

08-Jun-2020

C-V2X Scenario Simulation with R&S CMW500 Wideband Radio Communication Tester

This application Note is based on CMW500, SMBV100B and Vector CANoe.Car2x Software and guides to how to simulate the specific Cellular Vehicle-to-Everything (C-V2X) wireless environment in respect to road transport scenarios and transmitted messages around the Device Under Test (DUT) like a Telematics Control Unit (TCU). It shows how to verify and validate the C-V2X application of the DUT in laboratory environment. The virtual simulation scenario is not limited to the requirements of CSAE53-2017 specification, and it could be modified by user according to this operating guide with CANoe.Vehicle-to-everything (V2X) is a new generation of information and communications technologies that connect vehicles to everything. The objective of V2X is to increase road safety and manage traffic efficiently.C-V2X is designed to offer low-latency vehicle-to-vehicle (V2V), vehicle-to-roadside infrastructure (V2I) and vehicle-to-pedestrian (V2P) communications services to add a new dimension to future advanced driver assistance systems (ADAS). C-V2X as one communications standard defined by 3GPP in Release 14 uses LTE technology as the physical interface for communications. The standard describes two types of communications. The vehicle-to-network (V2N) communications type, exploits the cellular Uu interface, uses traditional cellular link to enable cloud services to be integrated into end-to-end solutions, e.g. to allow road and traffic information for a given area to be distributed to the vehicles.The second type is referred to as direct or PC5/Sidelink (V2V, V2I, V2P) communications, where data transmission takes place over the PC5 interface. In that type, C-V2X does not necessarily require a cellular network infrastructure. It can operate without a SIM and without network assistance and uses GNSS as its primary source for time synchronization.Verifying system functionality and performance exclusively by field testing in a real-world environment can be time-consuming, costly and very challenging. Requirements regarding functionality, and consequently the required assistance functions, are constantly changing. Due to this fact, test solutions are needed during the development and introduction phase to verify compliance with the standards. The PC5 direct communications type allows exchange of time sensitive and safety relevant information. Using a mobile communication tester like the R&S® CMW500 together with a C-V2X scenario simulation tool delivers reproducible test scenarios. This is essential for the standardization of verification processes for C-V2X in order to obtain reliable and comparable results, and it helps to demonstrate that end-to-end functionality between two C-V2X devices from different vendors works properly.

02-Jun-2021 | AN-No. GFM341

Tackling the Challenges of Pulsed Signal Measurements

This Application Note describes characterization of devices used in radar systems with pulsed signals. The emphasis is on measurements using vector network analyzers (VNAs), signal generators, vector signal generators and spectrum analyzers.

18-Jan-2008 | AN-No. 1MA124

Automotive Ethernet 1000Base-T1 TC9 measurement using VNA

This application note is a systematic guide to help test engineers configure the Vector Network Analyzer in order to perform compliance test on Automotive Ethernet cables according to the Open Alliance TC9 standard.

13-Aug-2019 | AN-No. GFM323

Comprehensive PCR Analysis - Using the R&S®DVM Family from Rohde & Schwarz R&S®DVM50/DVM100/DVM120/DVM400

When MPEG-2 transport streams are transmitted, the program clock reference PCR is transmitted as a time reference in the receiver. A sufficiently accurate and correctly received PCR is a precondition for correct data display in the receiver. This Application Note provides an overview of definitions, functions and use of the PCR. It also explains the recommended measurements of the current measurement guidelines and offers detailed instructions on how to use the PCR measurement functions of the R&S DVM family.

01-Jun-2006 | AN-No. 7BM55

Zone trigger for DDR read/write separation

Debugging and verifying the DDR DRAM memory interface in a system design can be challenging. The R&S®RTP high-performance oscilloscope zone trigger is ideal for READ/WRITE separation as a basis for analyzing signal integrity.

06-Feb-2025

Method of implementation (MOI) for IEEE up to 100 Gbps interface channel test

This application note describes Methods of Implementations (MOI) for precise, fast and error-free compliance testing of high-speed backplanes and direct attach copper cables (DAC) according to IEEE 802.3bj, IEEE 802.3by, IEEE 802.3cd and IEEE 802.3ck, based on 25 Gb/s, 50 Gb/s and 100 Gb/s signaling per lane with vector network analyzers from Rohde & Schwarz.

07-Apr-2021 | AN-No. GFM356

Automated compliance test solution for high speed Ethernet cables

Ensures compliance of IEEE 802.3bj/by/cd/ck cables with fast automation and easy testing.

04-Oct-2022

Simplify FiRa™ certification for your UWB device

The validated UWB PHY test suite for the R&S®CMP200 radio communication tester simplifies FiRa™ Consortium PHY conformance testing.

21-Jun-2022

CMUCopy - Transferring CMU Hardcopy to PC using the IEEE Bus or the serial interface

This application note has been replaced by application note .

28-Aug-2009 | AN-No. 1MA45

Conducted emissions in DC-DC converters – simulation versus measurement

Simulation can be a big time-saver when designing EMI filters for DC/DC converters. Power supply control chip vendors offer various filter design tools that provide reasonable design choices for filter simulation before any hardware prototype is available. However, simulated results can differ significantly for different tools if simulated models are not accurate or do not cover all the relevant components. Performing a hardware measurement to evaluate the effectiveness of a simulated EMI filter is therefore indispensable.

21-Sep-2021

AMR Testing on GSM Base Stations with R&S®CMU300

GSM Adaptive Multi-Rate (AMR) tests can be performed by using the R&S CMU300 as of software version V3.65. This document describes the scope of functions of the AMR Testing R&S CMU-K37 software expansion option.

26-Jul-2005 | AN-No. 1CM59

Generating Multiple Phase Coherent Signals – Aligned in Phase and Time

Rohde & Schwarz signal generators present a compact easy-to-use solution for generating phase coherent signals. Different generator models can be coupled to optimally fit user requirements in terms of number of phase coherent channels and RF frequency range.This application note explains how to generate phase coherent signals, details what to consider and how to best calibrate the relative phases and timing between the individual channels. This document also presents various measurements of the phase stability over time for different RF frequencies.

07-Sep-2016 | AN-No. 1GP108

Digital dividend: testing of TV receivers

The R&S®SFU broadcast test system is used as a reference signal generator to simulate the influence of LTE and other mobile radio signals on digital TV signals and receivers.

20-Jun-2012

NTP and ACP Measurements to ETS 300 175-2 for DECT using Spectrum Analyzer FSE

DECT standard ETS 300 175-2 prescribes among others measurement of the transmit power and the unwanted power in adjacent channels. Following a brief introduction into DECT, this Application Note describes the standard-conforming measurement of the normal transmit power NTP and the unwanted adjacent-channel power ACP using a spectrum analyzer from the FSE family ( firmware version 1.63 and higher). Option FSE-B7 (Vector Signal Analyzer) is required for measuring the normal transmit power NTP since the signal must be demodulated for this measurement. Due to the wide dynamic range of FSEA20 and FSEA30, the adjacent channel power ACP can be measured without bandpass filters suppressing the transmit channel. Option FSE-B7 is not required for measuring the adjacent-channel power.

28-Apr-1998 | AN-No. 1EF42

How network scanners verify C-V2X communication

For several years, vehicle manufacturers and government agencies have sought ways to increase road safety, manage traffic efficiently and, in the future, make driving more comfortable, convenient and safe. Vehicle-to-everything (V2X) is a new generation of information and communication technology that connects vehicles to everything and can support these objectives. V2X is designed to offer low-latency vehicle-to-vehicle (V2V), vehicle-to-roadside infrastructure (V2I) and vehicle-to-pedestrian (V2P) communications to add a new dimension to future driver assistance systems.Cellular V2X (C-V2X) is defined as the communications standard by 3GPP in Release 14 and uses LTE technology as the physical interface for communications.The LTE C-V2X Scanner provides customers an opportunity to verify, test, and optimize ITS traffic systems that are being deployed or are already established. The scanner accomplishes this by passively listening to PC (5.9GHz) messages that are being broadcast from RSU (roadside units), vehicles or any other C-V2X enabled device. Traditional scanner measurements regarding RF signal power and quality such as RSRP, RS-CINR and RSSI, are provided for each physical channel (PSCCH and PSSCH) as well as decoded ITS message content for all three regions (North America, EU, China).

21-Oct-2022 | AN-No. 8NT07

Radar Waveforms for A&D and Automotive Radar

This White Paper provides a more detailed view on radar waveforms for Aerospace and Defence and commercial radar systems. Waveforms such as pulse and pulse-Doppler signal, continuous wave and frequency shift keying waveforms are described. It also shows continuous waveform trends designed for specific needs and application differences of continuous wave radar compared to pulse radar systems.

31-Aug-2015 | AN-No. 1MA239

Measurements on 3GPP WCDMA User Equipment According to Standard TS 34.121

Application Note 1MA68 has been replaced by .

10-Dec-2008 | AN-No. 1MA68

Verify the energy efficiency of your O-RAN radio units

O-RAN radio units (O-RU) contribute significantly to the high power consumption of 5G networks. Making O-RUs energy efficient without sacrificing O-RAN innovations is a top priority.

19-Mar-2024

Rohde&Schwarz Smart Instruments Family300 Basic Programming Guide

Introduction to the fundamentals of programming the R&S Smart Instruments Family 300 in different developement environments.

25-Jun-2007 | AN-No. 1MA73

Introduction to MIMO

Modern radio communication systems have to provide higher and higher data rates. As conventional methods like using more bandwidth or higher order modulation types are limited, new methods of using the transmission channel have to be used. Multiple antenna systems (Multiple Input, Multiple Output – MIMO) gives a significant enhancement to data rate and channel capacity. This application note gives an introduction to basic MIMO concepts and terminology and explains how MIMO is implemented in different radio communications standards.

02-Jul-2009 | AN-No. 1MA142

ACP Measurement according to IS 54 (NADC) using the R&S®FSE Spectrum Analyzers

In digital wireless communication systems one or multiple users are assigned to a physical RF channel. With analog systems only one user per carrier is possible. Output spectrum of the transmitter has to be restricted to the assigned channel in order to avoid interference with the neighbor channels. With the switch over to digital modulation formats more user per channel are possible. They share one channel by using only part of the time for transmission (Time Division Multiplex Access, TDMA) or by coding the transmission by orthogonal sequences for distinction to other users (Code Division Multiples Access, CDMA). Beneath the restriction of modulation spectrum with TDMA systems also time behavior of the transmitted signal is critical. One reason is that in a multi-user situation only one user is allowed to transmit within his assigned time slots. Another reason is that by switching a carrier on and off spectrum of the transmitter splatters and causes additional interference in other RF channels.

17-Jan-2002 | AN-No. 1EF32

GPIB to LAN Converter for OSP

Some of the new Rohde & Schwarz instruments, such as the R&S®OSP and R&S®FSC, only have a LAN interface. To be able to operate these instruments in a purely GPIB system, a converter must be connected between the instrument and the GPIB. Rohde & Schwarz now offers such a GPIB to LAN converter.

03-Aug-2010 | AN-No. 1SP30

Minimizing power consumption

High-precision two-quadrant power supplies generate current profiles and simulate batteries

10-Dec-2020

  • 1
  • ...
  • 24
  • 25
  • 26
  • ...
  • 39
Results 721 - 750 of 1147
background
facebook
youtube
feed
LinkedIn
twitter
Rohde & Schwarz Norge AS
Rohde & Schwarz is striving for a safer and connected world with its leading-edge solutions. Committed to innovation for more than 90 years, the independent technology group acts long-term and sustainably, making it a reliable partner to its industry and government customers worldwide.
Address

Østensjøveien 34

0667 Oslo

Norway

Contact

+47 23 38 66 00

firmapost@rohde-schwarz.com

© 2025 Rohde & Schwarz

  • Cookie Information
  • Imprint
  • Statement of Privacy
  • Terms & conditions
  • Jobs & Career
  • Terms of use