The R&S®LCX-Z5 test fixture is designed for measuring transformers in combination with the measurement functions of the R&S®LCX LCR meters. The R&S®LCX-Z5 test fixture is designed for measuring transformers in combination with the measurement functions of the R&S®LCX LCR meters. Transformer Testing, R&S®LCX200 and R&S®LCX-Z5 Transformer Testing With R&S®LCX200 and R&S®LCX-Z5
The R&S®LCX LCR Meters come with a high-resolution touchscreen, a maximum frequency of up to 10 MHz, versatile measurement functions, and logging capabilities The R&S®LCX LCR Meters come with a high-resolution touchscreen, a maximum frequency of up to 10 MHz, versatile measurement functions, and logging capabilities LCX, component testing, LCX100, R&S®LCX200, Key features The R&S®LCX LCR Meters come
LCX, component testing, LCX-K108 Extended bias functions The R&S®LCX-K108 option allows the user to apply an external DC voltage bias of up to 10V and an internal DC current bias of up to 200mA to the DUT.
The R&S®LCX Z1/Z2/Z3/Z4/Z5 test fixtures from Rohde & Schwarz can perform measurements on a wide range of components. The R&S®LCX Z1/Z2/Z3/Z4/Z5 test fixtures from Rohde & Schwarz can perform measurements on a wide range of components. R&S LCX Test Fixtures. The R&S LCX Z1/Z2/Z3/Z4/Z5 test fixtures from Rohde&Schwarz can perform measurements on a wide range of components
LCX, LCR, sweep tool The sweep tool for the R&S®LCX LCR meters allows dynamic impedance measurements by sweeping test signal frequency, level, and DC bias.
Impedance Analyzers from Rohde & Schwarz are ideal for measuring impedance at a fixed frequency as well as for determining the best operating point for the component under test The LCR Meters and Impedance Analyzers from Rohde & Schwarz are ideal for measuring impedance at a fixed frequency as well as for determining the best operating point for the component under test Impedance Measurements using R&S LCX200
01-Mar-2023 | Press Releases | Test & measurement
Embedded world 2023: Rohde & Schwarz showcases its state-of-the-art test solutions for embedded systemsEmbedded systems are at the core of today’s electronic devices, whether in consumer electronics, telecommunications, industrial, medical, automotive or aerospace applications. Flawless operation is crucial, and engineers face complex challenges when designing ever more compact embedded systems which meet today’s demands of efficiency, safety, reliability and interoperability. Rohde & Schwarz addresses these challenges with its wide-ranging test and measurement solutions showcased at the embedded world Exhibition & Conference 2023 in Nuremberg.
White paper: Characterizing parasitic components in power converters
This webinar is intended for engineers who work on power converter design and testing.. Register now
Learn about the differences between LCR meters and VNAs. Learn how to measure impedance with a network analyzer and how LCR meter impedance measurement works.
Read this educational note and dive into the discussion about the six most important transformer measurements: turns ratio, mutual inductance, phase angle, primary and secondary inductance, leakage inductance, and interwinding capacitance.
28-Feb-2024
Explore an engineer’s toolbox with our comprehensive list of electronic test equipment. Learn about the instruments that define modern electronics testing.
Discover power electronics design verification solutions from Rohde & Schwarz, from research & development to production test.
This paper describes the characterization of aluminum electrolytic capacitors specifically used in AC-DC power converter applications. It will be discussed why this capacitor technology is critical regarding lifetime and why it cannot be substituted simply by any another capacitor technology. Different aging effects of the capacitor will be discussed. Usage of the capacitor in different AC-DC converter topologies will be presented. Simulation circuits will be used to analyze the capacitor in more detail before suitable measurements will be performed to demonstrate a real example of a switching-mode power supply (SMPS).After the introduction into the aluminum electrolytic capacitor basics and theory, this paper will also present all important and possible measurements of capacitor parameters, like capacitance, equivalent series resistance (ESR) and ripple current. This includes in-circuit measurement which can be performed with an oscilloscope. An LCR-bridge is used to obtain high accuracy measurements in addition. A comparison between the two measurement methods will be presented. Furthermore, the required measurement hardware for the in-circuit measurements and the bridge measurement will be discussed and presented.Lastly, two different lifetime calculation methods are presented and a real example is used to compare the advantages and disadvantages of the different methods.Thanks to Mr. Frank Puhane from Würth eiSos GmbH & Co. KG who provided me with all aluminum electrolytic capacitor samples including the prepared capacitor with build-in temperature sensors to perform all measurements. Furthermore, his great expertise was very beneficial and helpful to create this premium application note.
07-Feb-2023 | AN-No. 1SL388
Save up to 51 % on the most popular T&M instrument configurations
Save up to 51 % on the most popular T&M instrument configurations
Save up to 51 % on the most popular T&M instrument configurations
Save up to 51 % on the most popular T&M instrument configurations
Save up to 51 % on the most popular T&M instrument configurations
Power electronics T&M solutions | Component testing, product design, production and compliance testing - Flyer Brochures and Data Sheets Flyer