RTB, RTM, RTA: Acquire Mode "High Resolution" looses details?
To measure the time between the pulses I need a slow time base of 200 ms/div. Is there a way to get them visible with new scopes?
TM/RTA - Edge A/B Trigger - Remote commands for the trigger level
I do RMS measurement on a signal after switching the channels. Even with *OPC? or *WAI the result is implausible: 9.91e+37 . How can I get a correct result?
Delta Time Accuracy Calculation for my Oscilloscope
I use the oscilloscope in RUN continious mode. When I press "STOP" more than one acquisitions are shown. The waveforms are overlayed. Is there a way to prevent this?
I made some power measurements using my R&S RTA4004 that lead to questionable power results. What can I do to improve my results?
How can I switch between the input impedance of 50 Ohm and 1 MOhm by using SCPI command.
I want to install the RTB / RTM / RTA into a rack and I use the rackmount kit "ZZA-RTB2K". Is the ground of the oscilloscope then connected to the frame of the rack?
Programming examples for oscilloscopes.
We want to measure the voltage of the main line with our oscilloscope.
RTB/RTM/RTA - reduce Stop Frequency at FFT
When I set the frequency of the arbitrary generator to 10 KHz, the frequency of the output signal is 120 KHz. What is wrong here?
When I query the waveform with "CHANx:DATA?" the resolution is just that what is displayed on the screen. But I have manually changed the record length to achieve a high resolution. How do I get the data of the waveform with full resolution?
RTB/RTM/RTA: Other units than V or A at channels? RTB, TRM, RTA, RTB/RTM/RTA: Other units than V or A at channels? RTB, TRM, RTA,
I would like to measure the voltage at a certain time of a captured waveform. Do I need to use the cursor function? May I ask for the SCPI commands?
No synchronisation in Auto Trigger Mode
I am using the burst function of the function generator. But I can not find the remote command to set the burst to "manual".
Configuring the Probe Adapter RT-Z2T with remote commands
With active FFT it seems that the timebase setting can not be changed. Is there a way to do that?
I have saved some important screenshots in /INT/SCREEN path. Now I want to save/copy these data on a USB key or my PC.
I want to use the "Remote Display" function of the Instrument View software. Instead of the screen I just see a "white" area. My PC is connected via USB. How can I use it?
How can I copy the screen shots from the internal memory to an USB stick?
I have exported the waveform into a csv file. When I open the file in Excel, the values are completely wrong. How can I get correct values?
I have compared passive and active probes. It seems that the noise with active probes is higher. What is the reason and what can I do to reduce the noise?
LabView Driver rsrtx - Range of Configure Trigger Channel Level
How can I query the waveform data of the serveral segments?
I want to set the acquisition mode to Average + HR using SCPI commands. But I can not find the right command in the manual.
How can I find out that the measurement has been finished?
Cursors that follow the waveform
At old scopes there was no trigger necessary to run the X/Y mode. Why does the mode not work if no valid trigger condition is detected?
Saving a screenshot to an USB stick with remote commands
What is the calculation base for the sample rate on my R&S RTA / RTM series scope when using FFT?
RTM/RTA: Measurement on several pulses of a train.