196 Results
Describes the test fixture set for USB 2.
Describes the test fixture set for Ethernet compliance tests.
The RTP's Zone trigger allowes as the only oscilloscope in the world to isolate events in the time and the frequency domain. 12 12 RTP, oscilloscope, scope, MSO, Zone trigger, spectrum analysis, spectrogram, RF signal RTP- see the difference. Capture infrequent events in the spectrum.
Describes the high-impedance buffer amplifier and its usage.
Video, jitter, oscilloscopes Learn about the novel R&S approach to decomposite the individual jitter components with R&S®RTO or R&S®RTP oscilloscopes in order to gain more inside into your design.
Embedding & Equalization with the R&S RTP Oscilloscope (Part 2) Learn about how to configure cable emulation within the Embedding setup dialog
Describes the frequency converter board for 100BASE-T1 compliance tests (BroadR-Reach).
Embedding & Equalization with the R&S RTP Oscilloscope (Part 4) Learn how easy it is to configure a equalizer emulation within the Equalizer setup dialog. For interface standards such as USB, PCIe or DP, the necessary S-parameter files are included in the oscilloscope software.
Embedding & Equalization with the R&S RTP Oscilloscope (Part 3) The Eye Diagram is an effective tool to validate signal integrity. This video compares the eye diagram on a signal acquired at the output of a USB transmitter versus a waveform with some added cable emulation.
Describes the 10BASE-Te fixture board for compliance testing of the 10BASE-Te energy-efficient Ethernet (EEE) protocol variant.
08-Jun-2022 | Press Releases
Rohde & Schwarz presents its full range of embedded systems test solutions at embedded world 2022Nuremberg will be home to the international embedded industry once again during embedded world Exhibition & Conference. Rohde & Schwarz will be showing its latest test solutions from June 21 to 23, 2022 at booth 4-218 of Nuremberg Exhibition Centre. There, visitors can experience product highlights like the new generation of the R&S RTP high-performance oscilloscope, and they can learn from the Rohde & Schwarz experts about state-of-the art test solutions for all kinds of embedded systems.
To allow optimization early on in the R&D lab, Rohde & Schwarz provides a free tool to simplify conducted emissions debugging using oscilloscopes.
27-Sep-2021 | AN-No. 1SL372
Oscilloscope, RTP High-performance oscilloscope, Automotive Radar, Pulse Analysis, Demodulation, Mixer, Downconversion Demodulate radar pulses with built-in oscilloscope functions.
Oscilloscope, RTP High-performance oscilloscope, Automotive Radar, Pulse Analysis, MIMO, phase-coherant, Mixer, Downconversion Perform phase-coherent measurements on multiple antenna signals.
Oscilloscope, RTP High-performance oscilloscope, Automotive Radar, Pulse Analysis, Deembedding, Mixer, Downconversion Deembed mixers and other setup components in realtime.
Flexible solutions for quantum systems - Product Flyer
This application note provides an introduction to the DDR memory technology and explains common challenges, related to the specific nature of DDR data, command and control buses.
30-Oct-2020 | AN-No. GFM340
Instrument Health Guide For benchtop oscilloscopes - Brochure Brochures and Data Sheets Brochure
Analyzing automotive radar signals with an oscilloscope - eGuide - Miscellaneous
Oscilloscope, RTP High-performance oscilloscope, Integral waveform, Pulsed signal, math function Remove 1/f noise in an integral math waveform for analyzing sinusoidal or pulsed signas with advanced math functions.
R&S®Forum for Instrument Remote Control
28-Jun-2018 | AN-No. 1MA196
The new R&S FE110ST/SR TX/RX frontends extend the frequency range of Rohde & Schwarz signal sources such as the R&S SMW200A vector signal generator and signal analysis instruments such as the R&S RTP oscilloscope to cover the W band from 70 GHz to 110 GHz. They complement the company’s portfolio of easy-to-mount frontends.
Test and measurement solutions for medical and health applications - Brochure
R&S®VISA is a standardized software library that allows fast communications over diverse interfaces with a wide variety of T&M instruments that are detected on the network from PC applications.
26-May-2020 | AN-No. 1DC02
EMI Debugging with the R&S RTO and R&S RTE Oscilloscopes
25-Jun-2014 | AN-No. 1TD05
Buy more - Save more | Customize your oscilloscope configuration and save big - Flyer Brochures and Data Sheets Flyer
RF signal analysis with Rohde & Schwarz spectrum analyzers and oscilloscopes - Application Brochure
As DisplayPort evolves to support ultra-high resolutions and increased data rates, robust compliance testing is essential to ensure interoperability across devices and interconnects. This application note provides a structured overview of physical-layer testing for DisplayPort source transmitters and passive cables, aligned with VESA CTS v2.1. The note covers key test procedures using Rohde & Schwarz solutions, including oscilloscope-based measurement at standardized test points, automated test execution with ScopeSuite, and signal integrity debug via equalization and jitter decomposition. It further details cable characterization using mixed-mode S-parameter analysis on a Vector Network Analyzer (VNA), with support for simulated eye diagrams and TDR-based impedance diagnostics. Practical setup examples and product references are provided to help engineers perform repeatable, standards-compliant DisplayPort PHY validation.
16-Jul-2025 | AN-No. 1SL418
MIPI D-PHY is a low-power, cost-effective physical layer interface, essential in mobile devices and advanced technology systems. It's a high-speed, source-synchronous interface used in smartphone cameras, smartwatch displays, drones, in-car entertainment, automobile cameras, and radar sensors. This application note explores MIPI D-PHY's features, functionality, and testing practices for device compliance, addressing common issues. It highlights Rohde & Schwarz's equipment for ensuring compatibility and solving issues with MIPI D-PHY, aligned with MIPI D-PHY specification version 2.5.Developed by the MIPI Alliance, D-PHY connects cameras and displays to a host processor via CSI-2 or DSI protocols. It features a master-slave, asymmetrical design for reduced link complexity. Key aspects include a unidirectional clock, optional data signal directions, different data rates for half-duplex operation, point-to-point communication, and high-speed (HS) and low-power (LP) modes for data transfer and battery preservation. In HS mode, D-PHY uses differential signaling with specific impedance, while in LP mode, it operates in a single-ended manner with high impedance termination.The application note from Rohde & Schwarz provides insights into characterizing and debugging MIPI D-PHY, offering conformance verification with MIPI Alliance standards and protocol decoding options.
31-Jan-2024 | AN-No. 1SL410