Validating switching converter stability is vital for any power supply design. Frequency loop and load transient responses are often used to ensure switching converter stability. Even as frequency loop response becomes more important to design validation, load transient response is still commonly used. Load transient response can also be enhanced by visualizing the positive duty cycle for pulse width modulation (PWM) signals over time. A modern oscilloscope can do this, while also helping identify unknown converter effects.
09-May-2023
1SL391 audio, breakthrough, ETSI EN 301 489 Audio Breakthrough Assembly and Test Setup 1SL391 audio, breakthrough, ETSI EN 301 489
11-Oct-2022 | AN-No. 1SL391
Timing components such as low jitter oscillators and clocks are necessary to facilitate increasing data rates in high speed digital designs. As part of the overall system design, the components also have to perform in the system’s non-ideal power integrity environment and limit the power supply induced phase noise and jitter from power rail disturbances. Measuring the power supply noise rejection (PSNR) requires accurate generation and leveling of artificial, sinusoidal disturbances and measurement of resulting phase-noise and jitter impairments.
30-Sep-2020
This application note has been replaced by application note .
27-Oct-2009 | AN-No. 1MA56
The Rohde & Schwarz SFU supports several modes of level setting. This Application Note describes the differences between these modes and especially describes a method to achieve a seamless transition without any impact to the output signal during a change of settings on an Rohde & Schwarz SFU (Firmware version > 1.30).
23-Jun-2006 | AN-No. 7BM54
Signal generators are often used in automated test environment applications. The replacement of those instruments, e.g., due to malfunction or standard replacement procedures requires special care to be taken in consideration. Replacement of those instruments requires compabitiblity between the replacement and the replaced device in at least the electrical and remote-control features. This application note describes in detail how to use the emulation modes of the R&S® series SMA100A, SMB100A, SMF100A signal generators.
24-Jun-2008 | AN-No. 1GP71
This application note describes how to directly transfer S-Parameter Trace Data from R&S Network Analyzers to Microsoft Excel using a direct connection like GPIB or LAN. Prerequisites are a PC running Microsoft Excel, a R&S Network analyzer like ZVA, ZVB or ZVT as well as a working remote control connection between PC and instrument like GPIB or LAN / Ethernet.
22-Mar-2007 | AN-No. RSI02
Most of today's electronic devices draw non‑sinusoidal current. This gives rise to harmonic currents injected back into the public supply system. These need to be checked on all devices with the CE marking.
12-Oct-2018
A whole series of measurements has to be carried out for drafting an acceptance test report for a VHF sound broadcasting transmitter in compliance with ARD Specifications 5/3.1 (= TL 5820-3018 of the Deutsche Bundespost). As in most cases parameters like transmitter output power, frequency stability, spurious modulation, etc. have to be measured in the two stereo channels of the transmitter separately and at different modulation frequencies and frequency deviation, manual-controlled measurements are very time-consuming. In addition, a great variety of test equipment eg AF generator, stereodecoder, level meter, etc. is required for the measurements. FMAB with option FMA-B4 (AM/FM Calibrator / AF Generator) is ideally suitable for these measurements on VHF sound broadcasting receivers. The internal AF generator provides the signals required for the left and the right stereo channel. The MPX signal from the VHF transmitter is decoded by the built-in stereodecoder. As a result many of the tests and measurements required for the acceptance of VHF sound broadcasting receivers can be carried out without any additional test equipment being required. To give an example, a test program running under the graphics user interface Microsoft Windows has been developed for carrying out automatic power and modulation measurements via a PC.
04-Jun-1998 | AN-No. 1EF09
The following paragraphs are intended to show the capabilities of the Rohde&Schwarz Signal Generator SMT performing VOR air navigation receiver tests. The procedures presented should not be considered binding or mandatory. It is expected that the user once familiar with the use of SMT for VOR/ILS receiver tests will design and implement procedures which satisfy equipment and regulatory requirements.
06-Jul-1994 | AN-No. 1GPAN10
This application note describes how to use the generic interface in R&S®AdVISE for remote operation.
19-Jun-2020 | AN-No. 1S002
This Application Note briefly explains the theoretical background regarding phase noise before describing the phase noise option for the R&S SFU. You will see how the phase noise profile creator application software can be used to generate specific phase noise curves and how to output them with the aid of the R&S SFU.
22-Aug-2007 | AN-No. 7BM63
Using a Vector Network Analyzer from the ZVR family, not only magnitude and phase can be measured, but also group delay and even phase delay. Whereas phase delay measurements produce the highest accuracy for the electrical length of non-dispersive devices under test, such as coaxial cables, group delay measurements also give a detailed insight into the frequency dependent delay characteristics of dispersive devices, such as filters. In addition to the traditional step aperture technique, Vector Network Analyzers from the ZVR family offer a frequency aperture technique, which allows a well defined and constant aperture for group delay measurements also for a nonlinear frequency sweep.
28-Jul-1998 | AN-No. 1EZ35
How I/Q noise cancellation can help significantly improve the EVM performance of your signal and spectrum analyzer.
16-Nov-2023
Best practices for national regulatory authorities
Key points:Importance of field measurements: Traditional network planning tools and models only offer an estimated view of mobile coverage. Field measurements are conducted under real geographical and load conditions, and therefore provide a more accurate picture and can discover interferences more effectively. Coverage investigations: When deploying a mobile network, operators must adhere to regulatory standards and licensing conditions. As a result, regulatory authorities carry out field measurements on a regular or ad hoc basis to validate compliance or investigate customer complaints. This process identifies coverage gaps and areas of poor network quality, enabling regulatory authorities to take actions to enhance service quality for consumers and guide network expansion.Foster competition: If the field measurements of the coverage and performance are performed on a scale representative of a given country, the transparency of these results can promote healthy competition between operators and better service for consumers, which is essential for economic growth and social development.Measurement Techniques: The harmonized methodology for measuring and evaluating data throughput and QoE based on popular services is described in ETSI TR 103 559.
15-Apr-2024 | AN-No. 8NT14
A collection of frequently occurring customer questions on using the ZVR analyzer, calibration, virtual transform networks, and additional applications.
23-Jan-2002 | AN-No. 1EZ38
The Rohde & Schwarz power consumption analysis tool helps evaluate power consumption data collected with Rohde & Schwarz power supplies.
01-May-2023
Automated Solution with High Efficiency
5G New Radio (NR) presents dramatic challenges to the testing of User Equipment (UE) Power Amplifier (PA). Multiple frequency bands, flexible 5G operation mode, multiple PA performance metrics and the MIPI control interface increases the potential PA testing workload significantly. Manually repeating these tests under so many different scenarios can be costly and time consuming. An automated testing solution can help the test engineer to highly improve the testing efficiency.In this application note, it introduces an example of automated testing of 5G UE PA with R&S signal generator, signal and spectrum analyzer, vector signal explorer software, power meter along with power supply.The entire application note is organized with following structure:Chapter 2 outlines the challenges to 5G UE PA testing.Chapter 3 introduces the setup for 5G signal generation and analysis. For 5G signal generation, a batch program of converting *.CSV files with IQ vectors to ARB waveform files is introduced. For 5G signal analysis, the R&S®VSE software is recommended, which enables the separation of RF signal collection and measurement to improve testing efficiency.Chapter 4 provides the informative content about the integration of MIPI control interface for the PA ON/OFF state switching and register configuration.Chapter 5 gives a guide on the implementation of a quick power servo, in which the techniques to speed up the PA power level adjustment are discussed.Chapter 6 summarizes the automated testing procedure.
09-Aug-2021 | AN-No. 1SL365
Embedding and De-Embedding of virtual transformation networks for measuring scattering parameters with a ZVR or ZVC vector network analyzer.
25-Sep-1998 | AN-No. 1EZ45
An operator of a network of terrestrial transmitter stations wants to have the most cost-effective means of monitoring the network's numerous transmitter sites from a main monitoring center. Modern error sensors such as the R&S DVM50/100 and the R&S ETX-T are used for diverse monitoring functions at the individual transmitter sites as well as to transmit monitoring status to the main monitoring center. These error sensors have a function-rich SNMP agent designed specifically for this purpose. Simple network management protocol (SNMP). Despite the 'simple' in the protocol name, some users are still afraid to use it for remote control and monitoring. This Application Note therefore provides a user-friendly and practical look at, for example, how the monitoring functions via SNMP can be used for the R&S DVM. The following sections provide a brief look at the SNMP protocol, the R&S DVM/ETX implementation, and useful tools for working with SNMP. A description of how SNMP can be linked to various development environments (C++, C#, Java) is also provided.
16-Mar-2007 | AN-No. 7BM65
Automotive Infotainment Testing
21-Feb-2018
This application explains the setup and procedure to measure the exact time relationship between the CDMA RF signal and even-second clock. The accurate knowledge of this time relationship is e.g. necessary for test setups which require the synchronization of the R&S®CMU200’s CDMA2000 system with a GPS simulator.
09-Nov-2007 | AN-No. 1CM33
This document provides some technical background and guidance on how to optimize the measurement of one of the key performance parameters of WLAN transmitters - the Error Vector Magnitude (EVM).
IEEE 802.11be Extremely High Throughput (EHT), also known as Wi-Fi 7, is the latest amendment of the IEEE 802.11 standard and is still under development. This amendment focuses mainly on improved throughput. To do so, the most notable changes currently implemented are:► New modulation scheme: 4096-QAM (4K-QAM)► Larger bandwidth: 320 MHz► Support for 16x16 MU-MIMO► Enhanced resource allocation in OFDMAThis places special demands on the measurement equipment.
06-Sep-2022 | AN-No. 1EF114
Increasing demands on power distribution networks have resulted in smaller DC rails, as well as a proliferation of rails that ensure clean power reaches the pins of integrated circuits.
07-Mar-2017
End-to-end conformance testing of 4G and 5G next generation eCall (NG eCall) modules under controlled network conditions
13-May-2024
The IP connection security analysis solution for the R&S®CMW500 platform identifies IP connection vulnerabilities in telematics units at an early stage of development.
18-Jul-2017
This Application Note describes a software program that provides easy creation and transfer of Pulse Trains between a PC and the R&S SMB100A, R&S SMA100A and R&S SMF100A analog signal generators with the Pulse Train option; or between a PC and the ARB of R&S SMBV100A, R&S SMJ100A or R&S SMU200A vector signal generators.
10-May-2011 | AN-No. 1MA148
Recent mobile test methods could not evaluate the quality of data reduced speech signals with different coded and decoded signals. The Perceptual Evaluation of Speech Quality (PESQ) provides the solution for this measuring problem. CDMA2000 PESQ is an add-on tool for CMUgo for automatic measurement of the PESQ for CDMA2000 mobile phones according to recommendation ITU-T P.862.1 featuring selectable fading profiles and variable Additional White Gaussian Noise (AWGN).
05-Jan-2012 | AN-No. 1MA136
New technologies and applications like 6G communications and sensing extend into sub-THz frequencies in the D band and beyond. New semiconductor technologies and processes need to be commercialized to support these efforts.
12-Dec-2023
LoRa is one of the most popular low-power wireless sensor network technologies for implementation of the internet of things (IoT), offering long-range communications compared to technologies such as Zigbee. Its name is derived from "long range" and it operates in license-free ISM bands. LoRa is a physical proprietary radio communications technique that is based on spread spectrum modulation techniques derived from chirp spread spectrum (CSS) technology.