Search for Products
Find products for aerospace, defense, security, broadcast & media, networks & cybersecurity, and test & measurement.
Search for Products
Find products for aerospace, defense, security, broadcast & media, networks & cybersecurity, and test & measurement.
85 Results
The R&S RTO oscilloscopes supports decoding of serial interface with 8b10b based protocols. Explore the 8b10b triggering & decoding software here.
Low speed serial buses such as I2C/SPI, RS-232/UART and Manchester/NRZ on your Rohde & Schwarz instrument. Your oscilloscope can provide a system-level view of one or more serial buses time correlated with other system events
The R&S®RTO oscilloscope supports triggering and decoding of the MIPI-RFFE protocol. Learn more about the MIPI-RFFE oscilloscope software here.
R&S®RTO/RTE oscilloscopes support triggering and decoding of FlexRay buses, including FIBEX standard file import. Discover the FlexRay oscilloscope software.
R&S®RTP, RTO and RTE oscilloscopes support decoding of 10BASE-T and 100BASE-TX Ethernet. Explore the Ethernet decoding software here.
The R&S®RTO and R&S®RTE oscilloscopes support triggering and decoding of MDIO. Learn more about the MDIO triggering & decoding software here.
The R&S®RTO oscilloscopes enable debugging of USB-SSIC interfaces for gear 1 and 2. Explore the USB-SSIC triggering & decoding software here.
The R&S®RTP, R&S®RTO and R&S®RTE oscilloscopes support all data rates: high speed, full speed and low speed. Explore the triggering & decoding software here.
R&S®RTP and RTO oscilloscopes support decoding of 10BASE-T and 100BASE-TX Ethernet, as well as MDIO. Find out more about the decoding software here.
The R&S®RTO and R&S®RTE oscilloscopes support triggering and decoding of USB power delivery signals. Explore the triggering & decoding software here.
The R&S®RTO oscilloscope supports triggering and decoding of MIPI D-PHY based protocols DSI and CSI-2. Learn more about the MIPI D-PHY oscilloscope software.
Choose the R&S Manchester and NRZ oscilloscope software to trigger & decode any Manchester and NRZ coded serial protocol. Explore the features now.
The R&S®RTO, RTE and RTH oscilloscopes support triggering and decoding of the CAN flexible data rate. Explore the CAN-FD triggering & decoding software here.
The R&S®RTO and RTE oscilloscopes support triggering & decoding of clock extension peripheral interface buses. Explore the CXPI triggering & decoding software.
Triggering and decoding of 8b10b and PCI Express Gen 1.1 / 2.0 signals on Rohde & Schwarz oscilloscopes: Decoding using intuitive menu dialogs, detailed analysis, color-coded telegrams / tables. Trigger on errors and other protocol-specific fields, such as TLP and OS.
The R&S®RTO oscilloscope supports triggering and decoding of MIPI M-PHY physical layer and UniPro protocol layer. Learn more about the MIPI M-PHY software.
The R&S®RTP and RTO oscilloscopes supports triggering and decoding of USB 3.1 Gen 1 and Gen 2 signals. Explore the USB 3.1 triggering & decoding software here.
Many R&S oscilloscopes support triggering and decoding of ARINC 429 buses. Explore the ARINC triggering & decoding oscilloscope software here.
Triggering and decoding of various USB signals (incl. USB 1.1/2.0/3.2/PD/SSIC) on Rohde & Schwarz RTO and RTP oscilloscopes: Decoding using intuitive menu dialogs, detailed analysis, color-coded protocol fields, table display, etc.. Trigger on errors and other protocol-specific fields.
Rohde & Schwarz RTO/RTE/RTH oscilloscopes support triggering and decoding, including symbolic decoding with the SENT software option. Learn more here.
Many R&S oscilloscopes support triggering and decoding of MIL-STD-1553 buses. Explore the supported scopes and learn about MIL-1553 software here.
R&S®RTO and R&S®RTP oscilloscopes support triggering and decoding of the MIPI-RFFE protocol. Learn more about the MIPI-RFFE oscilloscope software here.
The Rohde & Schwarz options support signal integrity debugging and automated compliance testing of DDR5/ LPDDR5, DDR4/ LPDDR4 and DDR3/ DDR3L/ LPDDR3 interfaces. Learn more.
With the history and segmented memory software option you can scroll through past acquisitions and analyze the data using all oscilloscope tools. Learn more.
All Rohde & Schwarz oscilloscopes support triggering and decoding of CAN and LIN buses, including CAN DBC file import. Explore the software now.
All Rohde & Schwarz oscilloscopes support triggering and decoding of I²C, of 2-wire, 3-wire and 4-wire SPI buses. Learn more about the I²C/SPI software here.
All Rohde & Schwarz oscilloscopes support triggering and decoding of UART and of RS-232, RS-422 and RS-485 buses. Learn more about the software option here.
Rohde & Schwarz active differential probes offer high input impedance, high common-mode rejection and low added noise. See more benefits!
Single-ended active probes are used to accurately measure ground-referenced signals. R&S offers a variety of models with a bandwidth of up to 6 GHz. Learn more.
The clock data recovery oscilloscope software provides realtime clock recovery for non-return-to-zero (NRZ) serial data up to 5.0 Gbps. Learn more here.