9014 Results
Two R&S ETL TV analyzers or two R&S ETC compact TV analyzers are used to measure the receive level of a car antenna against that of a reference antenna. The R&S BCDRIVE broadcast drive test software exports measured data for display in Google Earth.
19-Feb-2015
Millimeter-Wave Measurements Using Converters of the R&S<sup>®</sup> ZVA Family
09-Oct-2007 | AN-No. 1EZ55
Remote Emulation with the R&S<sup>®</sup>SMF100A Microwave Signal Generator
11-Oct-2016 | AN-No. 1GP92
Remote Emulation with the R&S<sup>®</sup>NRP2 Power Meter
28-Feb-2012 | AN-No. 1GP83
This application note describes how all required performance tests can be performed quickly and easily by using vector signal generators.
11-May-2016 | AN-No. 1MA162
Obtain fast data reading for realtime filter tuning with the R&S®ZNB vector network analyzer from Rohde & Schwarz.
27-Nov-2019
The R&S®SMW200A GNSS simulator offers an easy and convenient way to test your receiver design against a wide variety of potential interferers and jammers.
28-Jan-2019
How to do Measurements according to TS 34.121 in presence of the HS-DPCCH with the R&S<sup>®</sup> CMU200
25-Nov-2005 | AN-No. 1CM62
Automatic Phase Noise Measurements with Modulation Analyzer FMA (or FMAB or FMB) and Option FMA-B8
03-Jun-1998 | AN-No. 1EF15
The terrestrial television standard DVB T2 is gaining in significance as a result of the growing scarcity of available frequencies. New systems are being tested in many countries around the world. Other countries have already completed the introductory phase for DVB T2. Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many viewers or even disrupt adjacent channels.A single instrument, the R&S®ETL TV analyzer, performs all required DVB-T2 transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commissioning and preventive maintenance.The measurements described here satisfy many country-specific and customer-specific test specifications. Users need only set the limit values accordingly.
23-Jul-2014 | AN-No. 7BM106
Tamper protection for monitoring networks in banks
07-Jul-2014
Transient Measurements on GSM/PCN Synthesizers
03-Jun-1998 | AN-No. 1EF08
Application Note Peak and Mean Power measurements on wideband FMCW radar signals
28-Jun-2019 | AN-No. 1EF107
Converting MediaFLO™ Waveform Files to R&S<sup>®</sup> SFU / SFE / SFE100 ARB Format Using IQWIZARD/WinIQSIM™ for R&S<sup>®</sup> SFx-K35 ARB
10-Nov-2008 | AN-No. 7BM73
Simulation of BCCH Channel of GSM/PCN Base Station with Signal Generator SME
01-Jul-1999 | AN-No. 1GPAN14
SMIQ/ABFS TV SMIQ/ABFS remote display
02-May-2002 | AN-No. 1GP54
Generation of Test Signals for IS-136 (NADC) with Signal Generator SME
01-Jul-1999 | AN-No. 1GPAN35
The R&S®Scope Rider is a handheld oscilloscope that features superior performance at the highest safety standards, combined with the debugging functionalities of a benchtop oscilloscope.
30-Dec-2015
R&S IMS Hardware Setup according IEC / EN 61000-4-6 (conducted immunity)
29-Mar-2007 | AN-No. 1SP31
This application note focuses on how to measure and analyze FMCW radar signals with up to 6 GHz bandwidth with an R&S® RTP oscilloscope.
07-Aug-2019 | AN-No. GFM318
Connectivity of R&S<sup>®</sup> Test Solutions with AWR<sup>®</sup> Visual System Simulator™ (VSS)
20-May-2010 | AN-No. 1MA174
This application note describes the basic frequency filter measurements that are often required during service repairs, during development and for training purposes.
27-Mar-2015 | AN-No. 1MA243
Rohde & Schwarz offers RF solid-state amplifiers for various frequencies ranging from 9 kHz to 6 GHz and delivering CW power up to 80 kW.
27-Apr-2016
A high frequency transformer is a key component when designing isolated switching mode power supplies (SMPS). Leakage inductance is essential in the control of many design parameters including efficiency, maximum voltage rating for switching elements and EMI when it comes to designs using customized transformers. Accurate measurement of this parasitic element is mandatory. The R&S®LCX LCR meter is ideal for this challenging measurement task.
15-Feb-2022
This document is divided in two parts and starts with an introduction in AC-DC conversion principles in general. It will present the most common circuits used for different power levels. The switching mode power supply (SMPS) converter will be the main focus as they are used everywhere in the electronics. Especially the flyback converter design in different flavors are highlighted. Nevertheless, all measurements are also applicable for other SMPS converter designs operating at higher power levels.In the second part of this document, most relevant testing methods and procedures of an AC-DC converter are highlighted. For each testing section, a fundamental part will be upfront discussed and it is followed by a presentation of a suitable measurement method. In this second part, the device under test (DUT) is considered as black box device and thus the structure is similar. Therefore, the testing parts consists of methods related to input tests, output tests and a combination of both like efficiency. Of course, some test performed at the output of the converter are also relevant for DC-DC converter, e.g. the validation of the output ripple.
14-Nov-2022 | AN-No. 1SL387
Common mode distortion of wide-bandgap power electronics probing
25-Nov-2024