Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
371 Results
RTP Oscilloscopes with External Frontends (Part 2 ) The R&S RTP oscilloscope offers a comprehensive set of tools for analysing widebad RF signals together with the external frontends downconverted. Start with powerful trigger events, responsive spectrum analysis or the unique IQ mode to prepare in depth signal analysis.
26-Mar-2024 | Press Release | Test & measurement
embedded world 2024: Rohde & Schwarz presents its cutting-edge test solutions for embedded systemsRohde & Schwarz offers comprehensive test and measurement solutions for embedded design challenges for today’s requirements for efficiency, safety, reliability and interoperability. The highlights will be showcased at the embedded world Exhibition & Conference 2024 in Nuremberg, Germany.
This example demonstrates the power of Advanced Eye analysis with the RTP oscilloscope on an Automotive Ethernet PAM4 signal at 5 Gbaud. PAM-N Analysis with the R&S RTP Oscilloscope (Part 3) Learn about key advantages of the PAM-N analysis option on the R&S RTP & RTO6 oscilloscopes together with the Advanced Eye option to characterize and verify signal transitions.
PAM-N Analysis with the R&S RTP Oscilloscope (Part 2) Learn about key advantages of the PAM-N analysis option on the R&S RTP & RTO6 oscilloscopes. In combination with the CDR option, obtain the fastest eye diagrams to characterize signal behaviour in seconds.
This additional option makes the R&S RTO and RTP oscilloscope to powerful multi-functional debug tools. Video, TDR/TDT, oscilloscopes, RTO, RTP Evaluate impedance and transmission loss of your signal traces with the RTO or RTP oscilloscope's TDR/TDT Analysis option.
12-Nov-2020 | Press Release | Test & measurement
R&S RTP oscilloscope from Rohde & Schwarz wins prestigious LEAP AwardThe R&S RTP high-performance oscilloscope was granted this year’s LEAP Award (Leadership in Engineering Achievement Program) in silver in the test and measurement category. The award is given annually to most innovative and forward-thinking products serving the design engineering space, and was selected by 14 judges from various engineering and ICT institutions.
Letter of invitation Club of radio engineers
17-Sep-2020 | Press Release | Test & measurement
Rohde & Schwarz offers bandwidth upgrades for selected oscilloscopes at no extra chargeBandwidth is the most important aspect of an oscilloscope. To support design engineers in current and future design challenges, Rohde & Schwarz is introducing an attractive promotion for selected oscilloscope models: when purchasing an R&S RTO2000 or R&S RTP, now customers can upgrade the bandwidth with no extra costs.
A sinus signal with i.e. 10 V peak-peak, frequency 1 MHz is applied. If I choose a vertical scale which is too small the peaks of the waveform are not displayed as they are out of range. Now I activate the digital filter in the “Vertical” menu à “Channel”. The frequency of the filter is also set to 1 MHz. Now even at very small vertical scales (i.e. 50 mV/div) the waveform is displayed completely, see screenshot. But the amplitude can not be correct. What goes wrong here?
Welcome to our webinar "Advanced Signal Analysis Capabilities with the Rohde & Schwarz Oscilloscopes".
RTP oscilloscopes can trigger on signals as small as 1/1000th of a vertical division thanks to digital triggering and adjustable hysteresis. 3 12 RTP, oscilloscope, scope, MSO, update rate, trigger, digital trigger RTP- see the difference. Trigger with highest sensitivity at full bandwidth.
The RTP oscilloscope extends traditional de-embedding capabilities with flexible filter structures directly in the acquisition path. This allows waveform correction in real time. For the first time, users can trigger on corrected waveforms and focus on debugging the true device characteristics. 9 12 RTP, oscilloscope, scope, MSO, user interface, tool bar, toolbar RTP- see the difference.
This site shows a lot of RTP videos
This video is a throwback to the European Microwave Week 2024 and takes you on a quick run-through of wideband signal generation and analysis in the sub-THz frequency range, featuring the SFI wideband IF vector signal generator, FC330 H-band converters, and RTP oscilloscope. vector signal generator, FC330, H-band converters, RTP, oscilloscope The Potential of Sub-THz Frequencies with the FC330ST/SR
The RTP addresses this with an hardware-based math approach in the acquisition path, enabling for the first time triggering on math signals. 10 12 RTP, oscilloscope, scope, MSO, differential, differential signal, common mode, trigger RTP- see the difference. Benefit from differential signal and common mode beeing calculated in real-time.
01-Mar-2023 | Press Release | Test & measurement
Embedded world 2023: Rohde & Schwarz showcases its state-of-the-art test solutions for embedded systemsEmbedded systems are at the core of today’s electronic devices, whether in consumer electronics, telecommunications, industrial, medical, automotive or aerospace applications. Flawless operation is crucial, and engineers face complex challenges when designing ever more compact embedded systems which meet today’s demands of efficiency, safety, reliability and interoperability. Rohde & Schwarz addresses these challenges with its wide-ranging test and measurement solutions showcased at the embedded world Exhibition & Conference 2023 in Nuremberg.
Volume Adjustment of the "BEEP"
FAQ - Decoding of SENT protocoll shows CRC errors
R&S Scope Suite - eMMC compliance test fails
Connection of DUT and Link partner with test fixture RT-ZF2
Oscilloscope, RTP High-performance oscilloscope, Energy measurement, Pulsed signal, math function Learn how to measure the energy of a pulsed sine wave signal with built-in advanced math functions of the R&S®RTP.
When I do RMS measurements and an offset is applied, the result changes. I could not see that effect on other scopes. What is wrong here?
Rohde & Schwarz Manual for Ethernet Compliance Test Fixture R&S®RT-ZF2. Describes the fixture boards and measurement preparations.
The RTP's Zone trigger allowes as the only oscilloscope in the world to isolate events in the time and the frequency domain. 12 12 RTP, oscilloscope, scope, MSO, Zone trigger, spectrum analysis, spectrogram, RF signal RTP- see the difference. Capture infrequent events in the spectrum.
Rohde & Schwarz Manual for frequency converter R&S®RT-ZF3.
Programming examples for oscilloscopes.
Verify the power integrity of your electronic designs with powerful testing tools by Rohde & Schwarz ► Get more information.
The Rohde & Schwarz manual describes the 1 MOhm high-impedance buffer amplifier for oscilloscopes with 50 ohm input impedance.
Rohde & Schwarz Manual for USB 2.0 Compliance Test Fixture Set R&S®RT-ZF1. Describes the fixture boards and measurement preparations.