244 Results
The Zoom function does not show any waveform data at specific settings, especially at slower timebases in combination with higher sample rates, High resolution and roll mode with more channels. The problem is gone if a lower sample rate is chosen.
RTP oscilloscope.
RTP Oscilloscopes with External Frontends (Part 2 ) The R&S RTP oscilloscope offers a comprehensive set of tools for analysing widebad RF signals together with the external frontends downconverted. Start with powerful trigger events, responsive spectrum analysis or the unique IQ mode to prepare in depth signal analysis.
Basic setup Learn more about the basic test setup of aautomotive radar device with a High-Performance RTP Oscilloscope. Learn more about the basic test setup of aautomotive radar device with a High-Performance RTP Oscilloscope. Oscilloscope, RTP High-performance oscilloscope, Automotive Radar, Pulse Analysis Learn more about the basic setup with a High-Performance RTP Oscilloscope.
This example demonstrates the power of Advanced Eye analysis with the RTP oscilloscope on an Automotive Ethernet PAM4 signal at 5 Gbaud. PAM-N Analysis with the R&S RTP Oscilloscope (Part 3) Learn about key advantages of the PAM-N analysis option on the R&S RTP & RTO6 oscilloscopes together with the Advanced Eye option to characterize and verify signal transitions.
Learn about the RTP toolbar.
PAM-N Analysis with the R&S RTP Oscilloscope (Part 2) Learn about key advantages of the PAM-N analysis option on the R&S RTP & RTO6 oscilloscopes. In combination with the CDR option, obtain the fastest eye diagrams to characterize signal behaviour in seconds.
12-Nov-2020 | Press Releases
R&S RTP oscilloscope from Rohde & Schwarz wins prestigious LEAP AwardThe R&S RTP high-performance oscilloscope was granted this year’s LEAP Award (Leadership in Engineering Achievement Program) in silver in the test and measurement category. The award is given annually to most innovative and forward-thinking products serving the design engineering space, and was selected by 14 judges from various engineering and ICT institutions.
This additional option makes the R&S RTO and RTP oscilloscope to powerful multi-functional debug tools. Video, TDR/TDT, oscilloscopes, RTO, RTP Evaluate impedance and transmission loss of your signal traces with the RTO or RTP oscilloscope's TDR/TDT Analysis option.
17-Sep-2020 | Press Releases
Rohde & Schwarz offers bandwidth upgrades for selected oscilloscopes at no extra chargeBandwidth is the most important aspect of an oscilloscope. To support design engineers in current and future design challenges, Rohde & Schwarz is introducing an attractive promotion for selected oscilloscope models: when purchasing an R&S RTO2000 or R&S RTP, now customers can upgrade the bandwidth with no extra costs.
01-Mar-2023 | Press Releases
Embedded world 2023: Rohde & Schwarz showcases its state-of-the-art test solutions for embedded systemsEmbedded systems are at the core of today’s electronic devices, whether in consumer electronics, telecommunications, industrial, medical, automotive or aerospace applications. Flawless operation is crucial, and engineers face complex challenges when designing ever more compact embedded systems which meet today’s demands of efficiency, safety, reliability and interoperability. Rohde & Schwarz addresses these challenges with its wide-ranging test and measurement solutions showcased at the embedded world Exhibition & Conference 2023 in Nuremberg.
A sinus signal with i.e. 10 V peak-peak, frequency 1 MHz is applied. If I choose a vertical scale which is too small the peaks of the waveform are not displayed as they are out of range. Now I activate the digital filter in the “Vertical” menu à “Channel”. The frequency of the filter is also set to 1 MHz. Now even at very small vertical scales (i.e. 50 mV/div) the waveform is displayed completely, see screenshot. But the amplitude can not be correct. What goes wrong here?
RTP oscilloscopes can trigger on signals as small as 1/1000th of a vertical division thanks to digital triggering and adjustable hysteresis. 3 12 RTP, oscilloscope, scope, MSO, update rate, trigger, digital trigger RTP- see the difference. Trigger with highest sensitivity at full bandwidth.
The RTP oscilloscope extends traditional de-embedding capabilities with flexible filter structures directly in the acquisition path. This allows waveform correction in real time. For the first time, users can trigger on corrected waveforms and focus on debugging the true device characteristics. 9 12 RTP, oscilloscope, scope, MSO, user interface, tool bar, toolbar RTP- see the difference.
This video is a throwback to the European Microwave Week 2024 and takes you on a quick run-through of wideband signal generation and analysis in the sub-THz frequency range, featuring the SFI wideband IF vector signal generator, FC330 H-band converters, and RTP oscilloscope. vector signal generator, FC330, H-band converters, RTP, oscilloscope The Potential of Sub-THz Frequencies with the FC330ST/SR
The RTP addresses this with an hardware-based math approach in the acquisition path, enabling for the first time triggering on math signals. 10 12 RTP, oscilloscope, scope, MSO, differential, differential signal, common mode, trigger RTP- see the difference. Benefit from differential signal and common mode beeing calculated in real-time.
Volume Adjustment of the "BEEP"
FAQ - Decoding of SENT protocoll shows CRC errors
R&S Scope Suite - eMMC compliance test fails
Connection of DUT and Link partner with test fixture RT-ZF2
Describes the test fixture set for Ethernet compliance tests.
Describes the test fixture set for USB 2.
Oscilloscope, RTP High-performance oscilloscope, Energy measurement, Pulsed signal, math function Learn how to measure the energy of a pulsed sine wave signal with built-in advanced math functions of the R&S®RTP.
When I do RMS measurements and an offset is applied, the result changes. I could not see that effect on other scopes. What is wrong here?
The RTP's Zone trigger allowes as the only oscilloscope in the world to isolate events in the time and the frequency domain. 12 12 RTP, oscilloscope, scope, MSO, Zone trigger, spectrum analysis, spectrogram, RF signal RTP- see the difference. Capture infrequent events in the spectrum.
Describes the high-impedance buffer amplifier and its usage.
Programming examples for oscilloscopes.
Video, jitter, oscilloscopes Learn about the novel R&S approach to decomposite the individual jitter components with R&S®RTO or R&S®RTP oscilloscopes in order to gain more inside into your design.
Embedding & Equalization with the R&S RTP Oscilloscope (Part 2) Learn about how to configure cable emulation within the Embedding setup dialog
Describes the frequency converter board for 100BASE-T1 compliance tests (BroadR-Reach).