Aerospace protocols

Trigger and decode oscilloscope software package

Aerospace protocols
Open Lightbox
Aerospace protocols, software

Key Facts

  • Supports multiple aerospace protocols, including: MIL-STD-1553, ARINC 429, SpaceWire
  • Bus configuration in seconds with auto detection of data rates and thresholds
  • Display decoded protocols as a color-coded honeycomb in the waveform diagram or in tabular format
  • Reliable triggering on protocol details such as frame start, frame content and errors
  • Powerful search and navigation capabilities
  • Multi-domain icon

Aerospace trigger and decode
 

R&S®RTO and R&S®RTP oscilloscopes supports triggering and decoding of MIL-STD-1553, ARINC 429, SpaceWire signals. R&S®MXO oscilloscopes support MIL-STD-1553 and ARINC 429 decoding. You can set up decoding in seconds. Results can be viewed as color-coded protocol frames and/or in table format for detailed analysis. Errors are identified reliably and efficiently with the hardware-accelerated trigger. You can trigger on protocol details such as frame start, frame content and errors.

Caractéristiques & avantages

Fast bus setup

The configuration for any given protocol is accomplished in just a few steps starting from the app cockpit. Once the bus to decode has been chosen, the connected channels have been selected and the correct levels have been set, decoding begins automatically.

Open Lightbox

Simple and quick configuration of aerospace decoding protocols

Color-coded protocol display

You can analyze decoded bus frames using a color-coded data overlay over the bus signal. Address and data content can be displayed in hex, bin and ASCII format. The flexible screen setup always gives you an excellent overview. Additionally, the protocols can be displayed in a concise table.

Open Lightbox

Aerospace protocol details displayed color-coded in the waveform and result table

Strong trigger capability

Trigger on specific aerospace bus packets, data and errors

Reliable isolation of protocol events and errors is possible with the protocol-specific trigger. Rohde & Schwarz oscilloscopes are ideal for finding errors quickly thanks to high acquisition rates that decode protocol-specific trigger results. Hardware based triggering on specific protocol content (addresses or data) is available as well as on protocol errors.

Open Lightbox

Select from a comprehensive list of protocol types for triggering to focus the acquisition on the details of interest

Powerful search and navigation capabilities

Comprehensive search functions simplify the analysis of long signal sequences. Search for waveforms based on various criteria, such as signal faults and protocol content. All detected events are shown in a table with timestamps. Individual events can be examined in a zoom window by easily navigating between events.

Open Lightbox

Search for protocol details in long acquisitions

Reliable decoding

The protocol dialog gives users additional settings to help ensure stable and reliable decoding. 

Open Lightbox

Advanced settings for aerospace bus decoding

Available models

Available models
Modèles
Serial standard
Label support
Search

R&S®RTO6-K530

Numéro de commande 1801.7031.02

Serial standard
ARINC 429/MIL-1553/SpaceWire
Label support
Search

R&S®RTP-K530

Numéro de commande 1803.6655.02

Serial standard
ARINC 429/MIL-1553/SpaceWire
Label support
Search

R&S®MXO4-K530

Numéro de commande 1335.5208.02

Serial standard
ARINC 429
Label support
Search

R&S®MXO5-K530

Numéro de commande 1802.1266.02

Serial standard
ARINC 429, MIL-1553
Label support
Search

R&S®MXO5C-K530

Numéro de commande 1803.1430.02

Serial standard
ARINC 429
Label support
Search

Demander des informations

Vous avez des questions ou besoin d'informations supplémentaires ? Remplissez simplement ce formulaire et nous vous recontacterons rapidement.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.