R&S®EPL EMI test receiver

Mix, match and upgrade for your EMI testing.

R&S®EPL EMI test receiver
Open Lightbox
R&S®EPL EMI test receiver
Open Lightbox
R&S®EPL EMI test receiver
Open Lightbox
R&S®EPL EMI test receiver
Open Lightbox
R&S®EPL EMI test receiver
Open Lightbox
R&S®EPL EMI test receiver
Open Lightbox
R&S®EPL EMI test receiver
Open Lightbox
R&S®EPL1007 EMI test receiver, front low R&S®EPL EMI test receiver video R&S®EPL1007 EMI test receiver, front high R&S®EPL1007 EMI test receiver, side view R&S®EPL1007 EMI test receiver, side view, feet R&S®EPL1007 EMI test receiver, back high R&S®EPL1000 EMI test receiver, front low

Key Facts

  • Testing from 5 kHz up to 7.125 GHz
  • Precompliance and compliance testing
  • Flexible option concept – buy what you need, upgrade at any time
  • Fast time domain scan
  • Battery operation for mains independent use

Perfect for quick and precise EMI measurements

For precompliance and compliance applications from 5 kHz up to 7.125 GHz

The R&S®EPL1000 is specially designed for conducted measurements up to 30 MHz. Even the base unit offers time domain scan and preselection with preamplifier and fully complies with CISPR 16-1-1. For flexible pricing, these features are optionally available for the R&S®EPL1001 and R&S®EPL1007 which measure up to 1 GHz/7.125 GHz. All models automatically perform EMI measurements over several individually defined frequency ranges. Results are easily saved and printed. The R&S®EPL also offers in-depth analysis functions including a real-time spectrogram and four-channel click rate analysis. Battery operation, 12 V to 24 V DC input, a carrying bag and other extras enable very flexible deployment of the R&S®EPL.

Caractéristiques & avantages

For all use cases

Up to CISPR 16-1-1 compliance

The R&S®EPL can be used both during the development phase and for certification. Provided RF and CISPR 16-1-1 relevant features include:

  • Hardware protection and attenuation of strong signals
  • Automatic use of full dynamic range and overload handling 
  • EMI bandwidths and detectors
With R&S®EPL1-B2 (included in R&S®EPL1000):
  • Improved measurement of broadband interferers and short pulses
  • Measurement of small signals
With R&S®EPL1-B1611 (included in R&S®EPL1000):
  • Full CISPR 16-1-1 compliance

Configuration and display of RF signal handling
Open Lightbox

Configuration and display of RF signal handling

Time domain scan

Fast measurement with time domain scan

Using RBWs as defined by CISPR, the R&S®EPL can measure an entire CISPR band A or B in a single measurement. Frequency ranges above 30 MHz are measured automatically in multiple steps of 20 MHz using CISPR band associated RBWs. Up to three traces can be activated with different detectors, including CISPR detectors. This enables fast standard-compliant EMI measurements directly with the detector required by the standard.

Illustration of the TDS segment width
Open Lightbox

Illustration of the TDS segment width

Convenient measurements

Strong features simplify the execution and documentation of EMI measurements

  • Automatic measurement of multiple frequency segments with individual settings (scan table)
  • Automated sequence of preview measurement, peak search and final measurement
  • Limit line display and checking to easily evaluate measurement results
  • Report generation to easily record, document and exchange results
  • Transducer factors to include characteristics of additional components used

Automatic measurement example
Open Lightbox

Automatic measurement example

Measurement of A and B bands for neutral and live lines.

EMI analysis

The extensive analysis features include

  • Four-channel click rate analysis
  • Bar graph – level at a frequency
  • Real-time spectrogram – level versus frequency and time
  • Zero span – level at a frequency versus time
  • IF analysis
  • AM/FM output
  • Spectrum analysis functions

Measurement example with spectrogram
Open Lightbox

Measurement example with spectrogram

Visualization of different EUT operating modes

Available models

Available models
Modèles
Frequency range

R&S®EPL1000

Numéro de commande 1350.4444.10

Frequency range
5 kHz to 30 MHz

R&S®EPL1001

Numéro de commande 1350.4444.11

Frequency range
5 kHz to 1 GHz; upgradeable to 7.125 GHz

R&S®EPL1007

Numéro de commande 1350.4444.17

Frequency range
5 kHz to 7.125 GHz

Available options

Hardware options
Produit
Désignation
R&S®EPL1-B2

Numéro de commande 1350.4015.02

Désignation

Preselection with preamplifier

R&S®FPL1-B4

Numéro de commande 1323.1902.02

Désignation

OCXO accurate reference frequency

High precision frequency reference

R&S®FPL1-B10

Numéro de commande 1323.1890.02

Désignation

GPIB interface

Additional interface for remote control by GPIB, plug-in unit

R&S®FPL1-B30

Numéro de commande 1323.1877.02

Désignation

DC Power supply for 12/24 V supply

R&S®FPL1-B31

Numéro de commande 1323.1725.02

Désignation

Li-Ion battery pack

R&S®EPL1-B91

Numéro de commande 1350.4073.02

Désignation

Internal generator 5 kHz to 30 MHz

Software options
Produit
Désignation
R&S®EPL1-B9

Numéro de commande 1350.4467.02

Désignation

Internal generator 5 kHz to 1 GHz

R&S®EPL1-B9

Numéro de commande 1350.4044.02

Désignation

Internal generator 5 kHz to 7.125 GHz

R&S®EPL1-B22

Numéro de commande 1350.4480.02

Désignation

Low-noise preamplifier 2 MHz to 1 GHz/7.125 GHz

R&S®EPL1-B1611

Numéro de commande 1350.4515.02

Désignation

CISPR 16-1-1 compliance

R&S®EPL1-K53

Numéro de commande 1350.4050.02

Désignation

Time domain scan

R&S®EPL1-K55E

Numéro de commande 1350.4473.02

Désignation

Real-time spectrogram

R&S®EPL1-K56

Numéro de commande 1350.4067.02

Désignation

IF analysis

R&S®EPL1-K59

Numéro de commande 1350.4509.02

Désignation

4-channel click rate analyzer

CISPR 14-1 ed. 6 and ed. 7 compliant software for 4 channel simultaneous gapless measurement for up to four hours.

R&S®FPL1-K7

Numéro de commande 1323.1731.02

Désignation

AM/FM/PM analog modulation analysis

Modulation analysis for analog (AM, FM, PM) modulated single carrier signals
(for use with the R&S®ZNL, the R&S®ZNLx-B1 is required )

R&S®EPL1-B7125

Numéro de commande 1350.4021.02

Désignation

Frequency upgrade 1 GHz to 7.125 GHz, only for delivered R&S®EPL1001

Accessories
Produit
Désignation
R&S®EPL1-Z1

Numéro de commande 1350.4296.02

Désignation

Protective hard cover

R&S®EPL1-Z2

Numéro de commande 1350.4309.02

Désignation

Soft carrying bag for R&S®EPL1000

R&S®EPL1-Z2

Numéro de commande 1353.6431.02

Désignation

Soft carrying bag for R&S®EPL1001/R&S®EPL1007

R&S®EPL1-Z3

Numéro de commande 1350.4315.02

Désignation

H-style shoulder harness (requires R&S®EPL1-Z2 option)

R&S®FPL1-Z4

Numéro de commande 1323.1677.02

Désignation

Spare battery pack

R&S®EPL1-Z6

Numéro de commande 1350.4321.02

Désignation

19" rackmount kit for R&S®EPL1000

R&S®EPL1-Z6

Numéro de commande 1353.6377.02

Désignation

19" rackmount kit for R&S®EPL1001/R&S®EPL1007

R&S®EPL1-B19

Numéro de commande 1350.4450.02

Désignation

Replacement SSD including controller unit

R&S®FSV-B34

Numéro de commande 1321.3950.02

Désignation

Charger for R&S®FSV-B32 lithium-ion battery pack

R&S®EZ-21

Numéro de commande 1107.2087.03

Désignation

Control Cable, 3 m

from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL1000 and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200

R&S®EZ-21

Numéro de commande 1107.2087.10

Désignation

Control Cable, 10 m

from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200 

R&S®DCV-2

Numéro de commande 0240.2193.09

Désignation

Documentation of calibration values

Demander des informations

Vous avez des questions ou besoin d'informations supplémentaires ? Remplissez simplement ce formulaire et nous vous recontacterons rapidement.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.