PAM-N Analysis with the R&S RTP Oscilloscope (Part 1) Learn about key advantages of the PAM-N analysis option on the R&S RTP & RTO6 oscilloscopes. Start with the Signal Configurator.
Embedding & Equalization with the R&S RTP Oscilloscope (Part 1) Learn about key advantages of the Embedding and Equalization option of the R&S RTP & RTO6 oscilloscopes. Start with the Signal Configurator.
The Zoom function does not show any waveform data at specific settings, especially at slower timebases in combination with higher sample rates, High resolution and roll mode with more channels. The problem is gone if a lower sample rate is chosen.
Secuencia SCPI para la configuración y consulta de datos para la opción de interfaz I/Q digital K11.
RTP Oscilloscopes with External Frontends (Part 2 ) The R&S RTP oscilloscope offers a comprehensive set of tools for analysing widebad RF signals together with the external frontends downconverted. Start with powerful trigger events, responsive spectrum analysis or the unique IQ mode to prepare in depth signal analysis.
Manual de Rohde & Schwarz para la opción de automatización ScopeSuite. Describe los procedimientos de test.
This example demonstrates the power of Advanced Eye analysis with the RTP oscilloscope on an Automotive Ethernet PAM4 signal at 5 Gbaud. PAM-N Analysis with the R&S RTP Oscilloscope (Part 3) Learn about key advantages of the PAM-N analysis option on the R&S RTP & RTO6 oscilloscopes together with the Advanced Eye option to characterize and verify signal transitions.
PAM-N Analysis with the R&S RTP Oscilloscope (Part 2) Learn about key advantages of the PAM-N analysis option on the R&S RTP & RTO6 oscilloscopes. In combination with the CDR option, obtain the fastest eye diagrams to characterize signal behaviour in seconds.
The RTP oscilloscope extends traditional de-embedding capabilities with flexible filter structures directly in the acquisition path. This allows waveform correction in real time. For the first time, users can trigger on corrected waveforms and focus on debugging the true device characteristics. 9 12 RTP, oscilloscope, scope, MSO, user interface, tool bar, toolbar RTP- see the difference.
Manual de Rohde & Schwarz para los ensayos de conformidad con eMMC. Describe los procedimientos de test.
The RTP addresses this with an hardware-based math approach in the acquisition path, enabling for the first time triggering on math signals. 10 12 RTP, oscilloscope, scope, MSO, differential, differential signal, common mode, trigger RTP- see the difference. Benefit from differential signal and common mode beeing calculated in real-time.
Nov 12, 2020 | Press Release | Test & measurement
R&S RTP oscilloscope from Rohde & Schwarz wins prestigious LEAP AwardThe R&S RTP high-performance oscilloscope was granted this year’s LEAP Award (Leadership in Engineering Achievement Program) in silver in the test and measurement category. The award is given annually to most innovative and forward-thinking products serving the design engineering space, and was selected by 14 judges from various engineering and ICT institutions.
Manual de usuario de Rohde & Schwarz para los ensayos de conformidad de Ethernet. Describe los procedimientos de test.
A sinus signal with i.e. 10 V peak-peak, frequency 1 MHz is applied. If I choose a vertical scale which is too small the peaks of the waveform are not displayed as they are out of range. Now I activate the digital filter in the “Vertical” menu à “Channel”. The frequency of the filter is also set to 1 MHz. Now even at very small vertical scales (i.e. 50 mV/div) the waveform is displayed completely, see screenshot. But the amplitude can not be correct. What goes wrong here?
Osciloscopio, osciloscopio de alto rendimiento RTP, radar para el sector automoción, análisis de pulsos Aprenda más sobre la configuración básica con un osciloscopio de alto rendimiento RTP.
RTP oscilloscopes can trigger on signals as small as 1/1000th of a vertical division thanks to digital triggering and adjustable hysteresis. 3 12 RTP, oscilloscope, scope, MSO, update rate, trigger, digital trigger RTP- see the difference. Trigger with highest sensitivity at full bandwidth.
Esta página incluye muchos vídeos del RTP
Esta opción adicional convierte los osciloscopios R&S RTO y RTP en potentes herramientas de depuración multifuncionales. Vídeo, TDR/TDT, osciloscopios, RTO, RTP Evalúe la pérdida de impedancia y transmisión de sus trazas de señal con la opción de análisis TDR/TDT de los osciloscopios RTO o RTP.
Sep 17, 2020 | Press Release | Test & measurement
Rohde & Schwarz offers bandwidth upgrades for selected oscilloscopes at no extra chargeBandwidth is the most important aspect of an oscilloscope. To support design engineers in current and future design challenges, Rohde & Schwarz is introducing an attractive promotion for selected oscilloscope models: when purchasing an R&S RTO2000 or R&S RTP, now customers can upgrade the bandwidth with no extra costs.
Models: R&S®RTP-K28
Models: R&S®RTO-K23, R&S®RTP-K23
Get started on this journey to accelerate your signal integrity verification and debugging! Join the webinar to learn how to unlock the full potential of your high-speed interfaces and ensure reliable system performance
Models: R&S®RTO-K22, R&S®RTP-K22
Models: R&S®RTO-K87, R&S®RTP-K87, R&S®RTO6-K87
Models: R&S®RTO-K88, R&S®RTP-K88, R&S®RTO6-K88
Models: R&S®RTP-K89, R&S®RTO-K89, R&S®RTO6-K89
Models: R&S®RTP-K25, R&S®RTO-K25, R&S®RTO6-K23
Models: R&S®RTO-K24, R&S®RTP-K24, R&S®RTO6-K24
Models: R&S®RTO-K86, R&S®RTP-K86, R&S®RTO6-K22