246 Resultados
The RTP addresses this with an hardware-based math approach in the acquisition path, enabling for the first time triggering on math signals. 10 12 RTP, oscilloscope, scope, MSO, differential, differential signal, common mode, trigger RTP- see the difference. Benefit from differential signal and common mode beeing calculated in real-time.
Describe los procedimientos de test para realizar los ensayos de conformidad Ethernet.
Mar 26, 2024 | Comunicado de prensa
embedded world 2024: Rohde & Schwarz presents its cutting-edge test solutions for embedded systemsRohde & Schwarz offers comprehensive test and measurement solutions for embedded design challenges for today’s requirements for efficiency, safety, reliability and interoperability. The highlights will be showcased at the embedded world Exhibition & Conference 2024 in Nuremberg, Germany.
Nov 12, 2020 | Comunicado de prensa
R&S RTP oscilloscope from Rohde & Schwarz wins prestigious LEAP AwardThe R&S RTP high-performance oscilloscope was granted this year’s LEAP Award (Leadership in Engineering Achievement Program) in silver in the test and measurement category. The award is given annually to most innovative and forward-thinking products serving the design engineering space, and was selected by 14 judges from various engineering and ICT institutions.
Osciloscopio, osciloscopio de alto rendimiento RTP, radar para el sector automoción, análisis de pulsos Aprenda más sobre la configuración básica con un osciloscopio de alto rendimiento RTP.
A sinus signal with i.e. 10 V peak-peak, frequency 1 MHz is applied. If I choose a vertical scale which is too small the peaks of the waveform are not displayed as they are out of range. Now I activate the digital filter in the “Vertical” menu à “Channel”. The frequency of the filter is also set to 1 MHz. Now even at very small vertical scales (i.e. 50 mV/div) the waveform is displayed completely, see screenshot. But the amplitude can not be correct. What goes wrong here?
RTP oscilloscopes can trigger on signals as small as 1/1000th of a vertical division thanks to digital triggering and adjustable hysteresis. 3 12 RTP, oscilloscope, scope, MSO, update rate, trigger, digital trigger RTP- see the difference. Trigger with highest sensitivity at full bandwidth.
Esta opción adicional convierte los osciloscopios R&S RTO y RTP en potentes herramientas de depuración multifuncionales. Vídeo, TDR/TDT, osciloscopios, RTO, RTP Evalúe la pérdida de impedancia y transmisión de sus trazas de señal con la opción de análisis TDR/TDT de los osciloscopios RTO o RTP.
Sep 17, 2020 | Comunicado de prensa
Rohde & Schwarz offers bandwidth upgrades for selected oscilloscopes at no extra chargeBandwidth is the most important aspect of an oscilloscope. To support design engineers in current and future design challenges, Rohde & Schwarz is introducing an attractive promotion for selected oscilloscope models: when purchasing an R&S RTO2000 or R&S RTP, now customers can upgrade the bandwidth with no extra costs.
Embedding & Equalization with the R&S RTP Oscilloscope (Part 2) Learn about how to configure cable emulation within the Embedding setup dialog
This video is a throwback to the European Microwave Week 2024 and takes you on a quick run-through of wideband signal generation and analysis in the sub-THz frequency range, featuring the SFI wideband IF vector signal generator, FC330 H-band converters, and RTP oscilloscope. vector signal generator, FC330, H-band converters, RTP, oscilloscope The Potential of Sub-THz Frequencies with the FC330ST/SR
Embedding & Equalization with the R&S RTP Oscilloscope (Part 4) Learn how easy it is to configure a equalizer emulation within the Equalizer setup dialog. For interface standards such as USB, PCIe or DP, the necessary S-parameter files are included in the oscilloscope software.
Embedding & Equalization with the R&S RTP Oscilloscope (Part 3) The Eye Diagram is an effective tool to validate signal integrity. This video compares the eye diagram on a signal acquired at the output of a USB transmitter versus a waveform with some added cable emulation.
Feb 08, 2021 | Comunicado de prensa
Rohde & Schwarz introduces the first trigger and decode solution for 1000BASE-T1 automotive EthernetRohde & Schwarz introduces the first trigger and decode solution for 1000BASE-T1 automotive Ethernet.
Ajuste de volumen del «pitido»
FAQ - Decoding of SENT protocoll shows CRC errors
Nov 05, 2020 | Comunicado de prensa
Eurofins partners with Rohde & Schwarz to bring Advanced Testing Kit to High Speed Interface Compliance Test ProgramsEurofins Digital Testing, a global leader in end-to-end quality assurance and testing services, and Rohde & Schwarz, a leading test and measurement expert, are working closely together to give customers access to the latest High-Speed Signal Analysis and Compliance Testing tools using the R&S RTP164 high performance oscilloscope. These will give Eurofins a competitive edge in testing high-speed interoperability. They will further provide certification services for high-speed communications technologies including USB.
Describe el accesorio de ensayos de conformidad para Ethernet.
Osciloscopio, osciloscopio de alto rendimiento RTP, medida de energía, señal pulsada, función matemática Aprenda a medir la energía de una señal de onda sinusoidal pulsada con funciones matemáticas avanzadas, incorporadas en el R&S®RTP.
Describe el accesorio de ensayos de conformidad de USB 2.
Conexión de dispositivo examinado y colateral de enlace con adaptador de fijación RT-ZF2
R&S Scope Suite - error en los ensayos de conformidad de eMMC
When I do RMS measurements and an offset is applied, the result changes. I could not see that effect on other scopes. What is wrong here?
Describe el adaptador de 1 MOhmio y su utilización.
Ejemplos de programación para osciloscopios.
Which test fixture for MDI mode conversion measurement at 100Base T1 Compliance Test?
He comparado sondas pasivas y activas. Parece que el ruido con las sondas activas es mayor. ¿Cuál es el motivo y qué puedo hacer para reducir el ruido?
I have exported the waveform into a csv file. When I open the file in Excel, the values are completely wrong. How can I get correct values?
Vídeo, jitter, osciloscopios Conozca el nuevo método de Rohde & Schwarz para la descomposición de los componentes individuales del jitter con los osciloscopios R&S®RTO o R&S®RTP y analice más a fondo sus diseños.
Describe el módulo convertidor de frecuencia para ensayos de conformidad con 100BASE-T1 (BroadR-Reach).