Key facts

  • Extension unit for the R&S®ZVA/ZVT network analyzer
  • For measurements of T/R modules, receivers, transceivers, power amplifiers
  • Base unit ready for high power measurements
  • R&S®ZVAX-TRM models up to 24/40/50/67 GHz
  • Flexible configuration for the required application

Extension unit for measurements on active components

Configurable signal conditioning for R&S®ZVA/ZVT

The configurable R&S®ZVAX‑TRM extension unit is used with an R&S®ZVA/R&S®ZVT network analyzer to provide signal conditioning for demanding measurements on active devices under test. For example, it allows measurements on pulsed signals or noise figure measurements on transmit/receive (T/R) modules. Together with an R&S®ZVA network analyzer, the R&S®ZVAX‑TRM provides customized test sets for applications up to 24/40/50/67 GHz (restrictions on some options for the 67 GHz model).

Features & benefits

Configurable test system

Flexible characterization of T/R modules

The R&S®ZVAX‑TRM is an extension unit for the R&S®ZVA/ZVT. The configurable external box adds hardware components required for transmit/receive modules or high-power testing. The base unit has two ports, couplers, and path access loops. Modules can be added as needed: output pre-amplifiers, combiners, pulse modulators, receiver pre-amplifiers. Uncoupling the options from the VNA protects it and maintains  full RF performance for the base unit when measuring without the R&S®ZVAX-TRM.

Convenient control via a graphical user interface
Show me more details

Convenient control via a graphical user interface

Excellent performance

Excellent performance data for measurements on T/R modules

The T/R module characteristics can be measured in both directions, making bidirectional pulse measurements possible. High output power levels are standard, even with a fully configured R&S®ZVAX-TRM.

Compact solution with open architecture

Signal access points to integrate external components and instruments

Measuring power or pulse profile calls for different test setups. To meet these requirements, the R&S®ZVAX-TRM offers the following:

  • Access to generator path (e.g. connect external power amplifiers)
  • Access to receiver path (e.g. connect attenuators for power measurements or to output signal to an external instrument)
  • Access to reverence signal (e.g. to utilize automatic level control)

Show me more details

Customized configuration

Get what you need

The R&S®ZVAX-TRM extension unit in its base configuration supports high-power two-port measurements up to +43 dBm (pulsed signals) and can easily loop in external components.
For greater flexibility the R&S®ZVAX-TRM functions can be expanded with diverse options such as:

  • pulse modulators
  • low-noise preamplifiers
  • output amplifiers
  • combiners

Show me more details

Available models

Available models
Models
Frequency range

R&S®ZVAX-TRM24

Order number 1322.6500.24

Click on order no. to copy
Order number 1322.6500.24 is now copied to your clipboard.
Frequency range
24 GHz

R&S®ZVAX-TRM40

Order number 1322.6500.40

Click on order no. to copy
Order number 1322.6500.40 is now copied to your clipboard.
Frequency range
40 GHz

R&S®ZVAX-TRM50

Order number 1322.6500.50

Click on order no. to copy
Order number 1322.6500.50 is now copied to your clipboard.
Frequency range
50 GHz

R&S®ZVAX-TRM67

Order number 1322.6500.67

Click on order no. to copy
Order number 1322.6500.67 is now copied to your clipboard.
Frequency range
67 GHz

Available options

R&S®ZVAX-TRM24 extension unit
Product
Description
R&S®ZVAX24B31

Order number 1322.7020.24

Click on order no. to copy
Order number 1322.7020.24 is now copied to your clipboard.
Description

Low-noise pre-amplifier for R&S®ZVAX-TRM24

10 MHz to 24 GHz, measurement path port 1

R&S®ZVAX24B32

Order number 1322.7036.24

Click on order no. to copy
Order number 1322.7036.24 is now copied to your clipboard.
Description

Low-noise pre-amplifier for R&S®ZVAX-TRM24

10 MHz to 24 GHz, measurement path port 2

R&S®ZVAX24B712

Order number 1322.6969.24

Click on order no. to copy
Order number 1322.6969.24 is now copied to your clipboard.
Description

Pulse modulators for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX24B73

Order number 1322.6975.24

Click on order no. to copy
Order number 1322.6975.24 is now copied to your clipboard.
Description

Pulse modulators for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate pulsed signals at network analyzer port 3 or at the R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX24B112

Order number 1322.6981.24

Click on order no. to copy
Order number 1322.6981.24 is now copied to your clipboard.
Description

Output amplifiers for R&S®ZVAX-TRM24

10 MHz to 24 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX24B134

Order number 1322.6998.24

Click on order no. to copy
Order number 1322.6998.24 is now copied to your clipboard.
Description

Output amplifiers for R&S®ZVAX-TRM24

10 MHz to 24 GHz, for increased output power at network analyzer port 3 and port 4 or at R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX24B213

Order number 1322.7007.24

Click on order no. to copy
Order number 1322.7007.24 is now copied to your clipboard.
Description

Combiner for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX24B224

Order number 1322.7013.24

Click on order no. to copy
Order number 1322.7013.24 is now copied to your clipboard.
Description

Combiner for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.