R&S®ScopeSync Oscilloscope Software

Oscilloscope synchronization software for MXO4, MXO5 and MXO5C

 

R&S®ScopeSync Oscilloscope Software
Show me more details

Key facts

  • Get R&S®ScopeSync as a standard feature with MXO4, MXO5 and MXO5C oscilloscopes (from firmware V2.6 onward)
  • Synchronize two oscilloscopes for measurements up to 16 channels
  • Set any combination of MXO4, MXO5 or MXO5C as your primary or secondary scope. The two scopes may have different bandwidths, sample rate, memory depth and channel count
  • Use measurements, math and applications, such as protocol decode on all 16 channels

R&S®ScopeSync synchronization of two oscilloscopes
 

  • Quickly synchronize two oscilloscopes for measurements up to 16 channels. There is no special equipment needed, just three simple physical connections and the two oscilloscopes are ready.
  • Connect LAN either directly between the oscilloscopes or both to a switch or both to a network.
  • Connect two BNC cables: connect the Trig out/in signal and connect both oscilloscopes to the same 10 MHz timebase clock to ensure accuracy.
Now, your R&S®ScopeSync physical connection is ready.

Features & benefits

Easily setup directly on the oscilloscope

Using the R&S®ScopeSync menu, enter the IP address of the secondary oscilloscope (see O2 Scope 2 in the user interface).

Show me more details

Align trigger with automatic deskew

R&S®ScopeSync automatically aligns both oscilloscope triggers to the same point in time. An auto-deskew feature measures the trigger out delay between two MXO oscilloscopes and uses this value to align trigger points. Simply connect the passive probes delivered with the oscilloscopes from channel 1 of both oscilloscopes to the same probe compensation signal and the oscilloscope will make the calculation for you.

Show me more details

Leverage all analysis capabilities on your oscilloscope

With all acquired signals in a single oscilloscope, use measurements, math and applications, such as protocol decode, choosing any of the oscilloscope channels as source.

Show me more details

Make up to 24 channel measurements

Up to 24 channel measurements can be made using a two-step process. Use a power splitter to divide the Trig out and 10 MHz Ref out signals from the primary oscilloscope to two secondary oscilloscopes. Import channels 9 to 16 using R&S®ScopeSync. Use GetSignals as second step to add channels 17 to 24 from the third oscilloscope.

Show me more details

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.