Rohde & Schwarz recognizes the potential risk of computer virus infection when connecting Windows®-based test instrumentation to other computers via local area networks (LANs), or using removable storage devices. This white paper introduces measures to minimize malware threats and discusses ways to mitigate risks while insuring that instrument performance is not compromised. The paper discusses the use of anti-virus software, with recommended configuration settings. It also outlines how to keep the Windows® XP operating system properly updated through regular installation of OS patches.
04-Oct-2012 | AN-No. 1EF73
An automated test solution based on the R&S®CMW wideband radio communication tester fully supports the new test cases for real-time submeter positioning.
10-Jun-2022
Communication systems according to IS-136 (NADC) use Time Division Multiplex Access (TDMA) for the communication between base station and mobile stations. There are 6 time slots available. Depending on the amount of data, which have to be transmitted, the system uses full rate channels or half rate channels. A full rate channel means, that the mobile is accessed every 3rd time slot (e.g time slot 1 and 3, time slot 2 and 4 or time slot 3 and 6). With half rate channels the mobile is accessed every 6th time slot. Full rate and half rate channels may be mixed on demand. The base stations transmit continous on their frequency. Depending on the used combination of full rate and half rate channels the base station uses a different sequence of synchronisation words. The mobile stations use bursted transmission with one of the synchronisation words S1 to S6 defined in the standard. Signal Generator SME is excellently suited to generate these signals to test either base station receivers or mobile phone receivers. Together with the modulation data supplied with this application note the SME serves as a signal source for various test and measurement applications in the whole frequency range of IS-136 (NADC).
01-Jul-1999 | AN-No. 1GPAN35
SMIQ/ABFS TV shows the SMIQ or ABFS display remotely on any Windows™ PC
02-May-2002 | AN-No. 1GP54
Despite the now standard digital distribution of video signals, analog video signals are still an integral part of AV terminals in the home. This application note covers the fundamentals of analog component signals and shows how the signal quality can be measured with the measuring equipment from Rohde & Schwarz.
28-May-2015 | AN-No. 7MH107
This application note describes the general setup and required equipment for EMC measurements according to the EMS standard IEC / EN 61000-4-6.
29-Mar-2007 | AN-No. 1SP31
This application note describes how to connect R&S® test and measurement products quickly and seamlessly to AWR® Visual System Simulator™ (VSS) via a GPIB or LAN interface. Using AWR® Connected™ customized for Rohde & Schwarz hardware and R&S® WinIQSIM2™ signal simulation software, the flexibility of digital radio standards is highlighted and its integration into VSS is demonstrated.
20-May-2010 | AN-No. 1MA174
A high frequency transformer is a key component when designing isolated switching mode power supplies (SMPS). Leakage inductance is essential in the control of many design parameters including efficiency, maximum voltage rating for switching elements and EMI when it comes to designs using customized transformers. Accurate measurement of this parasitic element is mandatory. The R&S®LCX LCR meter is ideal for this challenging measurement task.
15-Feb-2022
Unique automatic level controlled (ALC) based test setup using the R&S®ZVA vector network analyzer and R&S®BBA150 broadband amplifiers provides highly accurate and reproducible results in minimum test time.
27-Sep-2013
This appication note introduces a program suitable for generating and analyzing WiMAX IEEE 802.16 signals for power amplifier testing. The program allows the user to change the generator settings, to select specific pre-defined test parameters and to analyze the test results. The application note describes the test parameters and the features and capabilities of the program.
03-Aug-2007 | AN-No. RAC-0611-0025
3GPP TS36.141 defines conformance tests for EUTRA base stations (eNodeB). Release 14 added several tests, especially for enhanced License Assisted Access (eLAA).This application note describes how all required receiver (Rx) tests (TS36.141 Chapter 7) can be performed quickly and easily by using vector signal generators from Rohde & Schwarz. A few tests additionally require spectrum analyzers from Rohde & Schwarz.Examples illustrate the manual operation. A free software program enables and demonstrates remote operation.The LTE base station transmitter (Tx) tests (TS36.141 Chapter 6) are described in Application Note 1MA154.The LTE base station performance (Px) tests (TS36.141 Chapter 8) are described in Application Note 1MA162.
11-May-2016 | AN-No. 1MA195
The R&S CMU300 combines high-precision Node B parameter tests with layer 1 signalling processes for the first time. Thus, you can now test Node Bs under more realistic conditions as it was possible with existing concepts. This document describes the new measurement functions and provides an overview of their applications.
10-Nov-2005 | AN-No. 1CM58
7BM30 Digital TV,DTV,DVB,MPEG2,Broadcasting,Television,SFQ,EFA Phase Jitter in DTV Signals Phase Jitter in DTV Signals 7BM30 Digital TV,DTV,DVB,MPEG2,Broadcasting,Television,SFQ,EFA Phase Jitter in DTV Signals
16-May-2002 | AN-No. 7BM30
R&S®NESTOR cellular network analysis software supports law enforcement agencies in alibi verification by analyzing mobile network traces. R&S®NESTOR gives users reliable confirmation of whether an individual’s mobile phone was at a specific location at the time of a crime.
10-Apr-2024
This document is divided in two parts and starts with an introduction in AC-DC conversion principles in general. It will present the most common circuits used for different power levels. The switching mode power supply (SMPS) converter will be the main focus as they are used everywhere in the electronics. Especially the flyback converter design in different flavors are highlighted. Nevertheless, all measurements are also applicable for other SMPS converter designs operating at higher power levels.In the second part of this document, most relevant testing methods and procedures of an AC-DC converter are highlighted. For each testing section, a fundamental part will be upfront discussed and it is followed by a presentation of a suitable measurement method. In this second part, the device under test (DUT) is considered as black box device and thus the structure is similar. Therefore, the testing parts consists of methods related to input tests, output tests and a combination of both like efficiency. Of course, some test performed at the output of the converter are also relevant for DC-DC converter, e.g. the validation of the output ripple.
14-Nov-2022 | AN-No. 1SL387
Multichannel signal reception in parallel using digital downconverters in a monitoring receiver.
14-May-2014
Almost every switched-mode power supply (SMPS) needs an EMI (Electro Magnetic Interference) input filter to suppress any disturbances of the SMPS on the power lines. This requirement having an input filter in the design ensures that no negative effect will occur in other parts of the systems connected to the power lines. Therefore, the design and the validation of the input filter is a major task during a typical power supply design. The conducted emission (CE) test according to a specific standard is a suitable and a common validation method to release the design at the end of the development cycle. Nowadays, this conducted emission test will be performed as pre-compliance test during the development phase in the lab as well. In this case, the designer will obtain an early feedback whether the design has to be optimized regarding any disturbances present on the power lines. In most cases, the designer has to adjust the input filter to obtain a more effective suppression of disturbances generated by the SMPS. However, the designer needs to know details about the noise spectrum to optimize the input filter as effective as possible. In addition to magnitude and frequency information of the noise source, it would be very helpful to know whether the noise is generated by a common mode source or by a differential mode source. During the standard conducted emission test, common and differential mode noise is a combination in the measurement results and thus not possible to gain deeper insights. This document will describe a method to separate common-mode and differential-mode separation using two oscilloscope channels. This separation approach works without any additional hardware component like a noise separator. The designer will be able to distinguish between common-mode (CM) and differential-mode (DM) noise. This additional information about the dominant mode provides the capability to optimize input filters very efficiently.
17-Sep-2020 | AN-No. GFM353
Testing radar warning equipment in realistic scenarios is crucial to reliable field performance. This typically involved dedicated instruments or test systems. Commercial vector signal generators (VSG) such as the R&S®SMW200A from Rohde & Schwarz have become a very attractive alternative thanks to their increased available bandwidth and processing power.
13-Aug-2020
R&S®AdVISE is a visual inspection software to monitor different regions of interest (ROIs) in a video for visible and audible changes. It automates the process of visually monitoring equipment under test during a test sequence and therefore eliminates human inattention, ensures reproducible results and simplifies the test documentation. R&S®AdVISE offers the possibility to monitor up to 32 ROIs in one video with 12 different specialized ROI types for different kinds of events. That allows the user to apply R&S®AdVISE to all sorts of individual test setups.This application note explains how to setup R&S®AdVISE to monitor the temperature of an EUT by using an infrared camera.
14-Sep-2020 | AN-No. 1S008
The following application note describes the function and operation of user menus for FSE Spectrum Analyzers including option Vector Signal Analysis (FSE-B7). For measurements according to the PCS 1900 standard for Mobile Stations user menus are provided, which perform settings on FSE for the different measurements required in the standard. The menu and the accompanying setups are stored on a floppy disk.
01-Nov-1996 | AN-No. 1EF22
What are the two key benefits of oscilloscopes with deep acquisition memory?
13-Dec-2017
The R&S®SMW200A GNSS simulator offers an easy and convenient way to test your receiver design against a wide variety of potential interferers and jammers. Test cases extend from simple coexistence simulations to complex interference scenarios with localized emitters.
28-Jan-2019
CST® Filter Designer 3D, which is part of the CST Studio Suite® simulation software from Dassault Systèmes, is a complete synthesis tool for filters and diplexers. It provides a range of solutions throughout the design process of coupled resonator filters and even beyond with its VNA based tuning capability. CST Filter Designer 3D assists in tuning filter hardware, significantly reducing the time for optimizing a device to meet the expected specifications. An attractive instrument to obtain fast data reading for realtime filter tuning is the R&S®ZNB vector network analyzer from Rohde & Schwarz.
27-Nov-2019
Simultaneous DL throughput verification and UL transmission testing with the R&S®CMW500
29-Jul-2009
With the extension of the 3GPP FDD system to include HSDPA, the HS-DPCCH has been added as a new code channel in the uplink. This Application Note describes the transmitter measurements provided by the CMU200 to perform the transmitter measurements defined in TS 34.121 in presence of the HS-DPCCH. CMU200 receiver measurements according to TS 34.121 that measure the throughput and the CQI reporting are described. Subject to change – T. Braun, November 2005 - 1CM62
25-Nov-2005 | AN-No. 1CM62
Current Radar development is focusing the area of signal processing. This is taken into account by this educational note, where the R&S®SMW / SMBV instruments on the transmitter side and R&S®FSW / FSV instruments on the receiver side are combined to a closed loop Radar system, performing radar detection by means of pulse compression and digital signal processing. Appropriate Rohde & Schwarz sofware tools for such applications are described as well as the interface between the tools and the test instruments. Target reader group are engineering students who want to perform tests using pulsed or chirped signals.
20-Nov-2014 | AN-No. 1MA234
The impedance of real-world passive components depends on frequency, signal level and DC bias. This has to be taken into account during circuit design. The R&S®LCX LCR meter is ideal for measuring these dependencies. The R&S®LCX sweep tool is an application program for conveniently performing such sweeps and displaying the results on charts.
17-Mar-2022
The general characterization of complex DUTs such as amplifiers requires the measurement of several parameters. Some may require more than one test device or expensive equipment. Thanks to its versatility, the R&S®ZNL is an economic solution that can characterize a variety of DUTs both via network analysis and spectrum analysis.
17-Dec-2021
Generation of wideband digital modulated signals in V-band and above is a challenging task and typically requires a set of multiple instruments. This application note aims at simplifying the task and looks into the analysis part as well. Latest signal and spectrum analyzers like the R&S®FSW67 and R&S®FSW85 are first to allow use in V-band up to 67 GHz and E-band up to 85 GHz respectively without external frequency conversion. Up to 8.3 GHz of modulation bandwidth can be covered using the R&S®FSW-B8001 option. Millimeter wave use of analyzers ranging from 26 GHz up is shown. Application note 1MA217 describes V-band signal generation and analysis up to 500 MHz modulation bandwidth. This application note expands modulation bandwidth up to 2 GHz and covers both V- and E-band examples.
18-Jun-2015 | AN-No. 1MA257