TDR/TDT analysis Oscilloscope software

General analysis

TDR/TDT analysis Oscilloscope software
Show me more details
TDR/TDT analysis Oscilloscope software
Show me more details
TDR/TDT analysis Oscilloscope software
Show me more details
TDR/TDT analysis Oscilloscope software
Show me more details

Key facts

  • Supports single-ended and differential TDR/TDT analysis
  • Uses the internal R&S®RTO/RTP-B7 16 GHz differential pulse source
  • A wizard guides through calibration and measurement
  • Multi-domain icon

Oscilloscope software

The R&S®RTO/RTP-K130 option combines the R&S®RTO/RTP-B7 pulse source and the analog input channels of the R&S®RTO or RTP oscilloscope to create a time domain reflection (TDR) and transmission (TDT) analysis system that helps characterize and debug signal paths, including PCB traces, cables and connectors. The option allows both single-ended and differential measurements (only with RTP).

Features & benefits

Single-ended and differential TDR/TDT

The R&S®RTO/RTP-B7 pulse source provides a highly symmetrical differential pulse signal with a steep rise time of 22 ps. This enables either single-ended or differential time domain reflection (TDR) and/or transmission (TDT)  analysis with the R&S®RTP. The R&S®RTO only supports single-ended TDR/TDT measurements. 

Single-ended TDR
Show me more details

Single-ended TDR

Setup dialog for the configuration of a single-ended time domain reflectometry (TDR) measurement. Display of impedance and reflection coefficient over distance.

Wizard support for calibration and measurement

Guided operation

The TDR/TDT wizard guides users through the test setup calibration based on the selected measurement type (TDR, TDR/TDT, TDT) and configuration (single-ended or differential). The wizard then uses illustrations to help with the test setup and parameter definition for the measurement.

Wizard for calibration TDR/TDT setups
Show me more details

Wizard for calibration TDR/TDT setups

A wizard guides users through the TDR/TDT setup calibration.

Complete solution

Fully integrated

The R&S®RTP-K130 TDT/TDR analysis option and R&S®RTO/RTP-B7 pulse option are fully integrated in the oscilloscope graphical user interface. The pulse option includes all the calibration and measurement accessories, such as shorts, 50 Ohm terminations or cables. The R&S®RT-Z17 low-loss and phase-matched cable pair is required for differential measurements.

Show me more details

Available models

Available options

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.