  • Bandwidth: 70 MHz to 300 MHz
  • Sample rate: up to 2.5 Gsample/s
  • Memory depth: up to 20 Msample
  • ADC resolution: 10 bit
  • Display: 10.1" capacitive touchscreen

Power of ten for every task, everyday

The R&S®RTB 2 series oscilloscopes combine the power of ten with smart operating concepts, making them the ideal all-purpose tool for students, hobbyists, technicians and engineers. As a successor to the highly capable R&S®RTB2000, the R&S®RTB 2 series features a 10-bit ADC, 10 Msample memory, and a 10.1-inch touchscreen.

Additionally, the R&S®RTB 2 series includes an integrated arbitrary waveform generator history and segmented memory capabilities. Furthermore, all RTB 2 models are MSO-ready, allowing the use of up to 16 digital channels with the appropriate probes.

These oscilloscopes offer four times the vertical resolution of standard 8-bit ADCs while maintaining fast sampling rates at all times. With the largest display and highest resolution in their class, they provide extensive capabilities for university laboratories, troubleshooting embedded designs during development, and for production and service departments.

The R&S®RTB 2 series is the perfect solution for anyone needing precise and reliable measurements.

Features & benefits

Signal analysis: quick results

See small signal details in the presence of large signals

The R&S®RTB 2 features a customized Rohde & Schwarz engineered 10-bit A/D converter that delivers a fourfold improvement compared to conventional 8-bit A/D converters. The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltage across the switching device must be determined during the on/off times within the same acquisition.

10-bit A/D converter
Abrir o Lightbox

10-bit A/D converter

The Rohde & Schwarz designed 10-bit A/D converter ensures the highest signal fidelity at the highest resolution.

Capture more time at full bandwidth

10 Msample standard and 20 Msample interleaved

The R&S®RTB 2 offers a class-leading memory depth: 10 Msample per channel are available, even 20 Msample in interleaved mode. This is 10 times more than similar oscilloscopes in the same instrument class. The user captures longer acquisition sequences even at high sampling rates, e.g. when analyzing transients of switched-mode power supplies, and thus benefits from more detailed analysis results.

10 Msample standard memory
Abrir o Lightbox

10 Msample standard memory

Capture and analyze pulsed and burst signals over a long period with up to 20 Msample standard acquisition memory.

Segmented memory

160 Msample with history function

Every R&S®RTB 2 is equipped with a standard segmented memory functionality. Protocol-based signals with communications gaps such as I²C or SPI can be captured over several seconds or minutes. The variable segment size optimally utilizes the 160 Msample memory. In history mode, previous acquisitions in the maximum segmented memory depth of 160 Msample are available for further analysis.

160 Mpoint segmented memory
Abrir o Lightbox

160 Mpoint segmented memory

Capture the longest time periods with class-leading 160 Msample memory.

Logic analysis with the MSO option

16 additional digital channels

Every R&S®RTB 2 is MSO ready, which allows the R&S®RTB2-B1 option to enable up to 16 additional digital channels. The oscilloscope captures and analyzes signals from analog and digital components of an embedded design – synchronously and time-correlated to each other. For example, the delay between A/D converter input and output can conveniently be determined with the cursor measurements.

Four-bit DAC signal change.
Abrir o Lightbox

Four-bit DAC signal change.

The R&S®RTB 2 captures and analyzes analog and digital signals synchronously and in time-correlated to each other.

Waveform and pattern generator

Generate analog and digital stimuli

The R&S®RTB-B6 waveform and pattern generator up to 50 Mbit/s is useful for educational purposes and for implementing prototype hardware. Apart from the common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Predefined patterns including. I2C, SPI, UART and CAN/LIN can be used.

Waveform and pattern generator
Abrir o Lightbox

Waveform and pattern generator

In addition to common sine, square/pulse, ramp and noise waveforms, it outputs user-defined waveforms and 4-bit signal patterns.

Digital voltmeter

Measure and display electrical potential

The R&S®RTB 2 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel for simultaneous measurements. Standard measurement functions include DC, AC+DC (RMS) and AC (RMS).

Digital voltmeter
Abrir o Lightbox

Digital voltmeter

The 3-digit voltmeter measures and displays the electrical potential difference between two points in an electric circuit.

Frequency analysis mode

Difficult-to-find faults often result from the interaction between time and frequency signals. The FFT function of the R&S®RTB 2 is activated at the push of a button and by simply entering the center frequency and span. Thanks to the R&S®RTB 2 oscilloscopes’ high-performance FFT functionality, signals can be analyzed with up to 128 kpoints. Other practical tools include cursor measurements and autoset in frequency domain.

Frequency analysis mode
Abrir o Lightbox

Frequency analysis mode

The high-performance FFT functionality analyzes signals up to 128 kpoints.

Mask test mode

Mask tests quickly reveal whether a specific signal lies within defined tolerance limits. By using statistical pass/fail evaluation, they assess quality and stability of a DUT. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation can generate a pulse output at the AUX-OUT connector on the R&S®RTB 2. This pulse output can be used to trigger actions in the measurement setup.

Mask test with result statistics
Abrir o Lightbox

Mask test with result statistics

The pass/fail evaluation assesses DUT quality and stability.

Ready for the teaching lab

In the teaching lab, the R&S®RTB 2 oscilloscope is the perfect choice to teach students how to measure with an oscilloscope. It has an easy-to-use concept combined with state-of-the-art technology at an affordable price. The large 10.1" high-resolution screen shows every signal detail, and one instrument can be shared among several students. Reports can be efficiently created with the handy, flexible screen annotation tool.

Ready for the teaching lab
Abrir o Lightbox

Ready for the teaching lab

Perfect instruments for everyday use at universities and colleges thanks to diverse functionality, rugged design and a small footprint.

Available models

Available models
Modelos
Bandwidth
Channels
Sample rate
Max. memory depth
Optional MSO
Começando em

R&S®RTB22

Order Number 1333.1005.02

Bandwidth
70 MHz
Channels
2
Sample rate
2.5 Gsample/s
Max. memory depth
20 Mpts
Optional MSO
16 digital channels
Começando em
Consultar preço

R&S®RTB24

Order Number 1333.1005.04

Bandwidth
70 MHz
Channels
4
Sample rate
2.5 Gsample/s
Max. memory depth
20 Mpts
Optional MSO
16 digital channels
Começando em
Consultar preço

R&S®RTB22-70

Order Number 1333.1005P40

Bandwidth
70 MHz
Channels
2
Sample rate
2.5 Gsample/s
Max. memory depth
20 Mpts
Optional MSO
16 digital channels
Começando em
Consultar preço

R&S®RTB22-100

Order Number 1333.1005P41

Bandwidth
100 MHz
Channels
2
Sample rate
2.5 Gsample/s
Max. memory depth
20 Mpts
Optional MSO
16 digital channels
Começando em
Consultar preço

R&S®RTB22-200

Order Number 1333.1005P42

Bandwidth
200 MHz
Channels
2
Sample rate
2.5 Gsample/s
Max. memory depth
20 Mpts
Optional MSO
16 digital channels
Começando em
Consultar preço

R&S®RTB22-300

Order Number 1333.1005P43

Bandwidth
300 MHz
Channels
2
Sample rate
2.5 Gsample/s
Max. memory depth
20 Mpts
Optional MSO
16 digital channels
Começando em
Consultar preço

R&S®RTB24-70

Order Number 1333.1005P50

Bandwidth
70 MHz
Channels
4
Sample rate
2.5 Gsample/s
Max. memory depth
20 Mpts
Optional MSO
16 digital channels
Começando em
Consultar preço

R&S®RTB24-100

Order Number 1333.1005P51

Bandwidth
100 MHz
Channels
4
Sample rate
2.5 Gsample/s
Max. memory depth
20 Mpts
Optional MSO
16 digital channels
Começando em
Consultar preço

R&S®RTB24-200

Order Number 1333.1005P52

Bandwidth
200 MHz
Channels
4
Sample rate
2.5 Gsample/s
Max. memory depth
20 Mpts
Optional MSO
16 digital channels
Começando em
Consultar preço

R&S®RTB24-300

Order Number 1333.1005P53

Bandwidth
300 MHz
Channels
4
Sample rate
2.5 Gsample/s
Max. memory depth
20 Mpts
Optional MSO
16 digital channels
Começando em
Consultar preço
Specifications
Vertical system
Analog channels R&S®RTB 22; R&S®RTB 24 2; 4
Digital channels (opt.) 16
Bandwidth (-3 dB) R&S®RTB 22/24 (with R&S®RTB-B2x1, R&S®RTB-B2x2 and R&S®RTB-B2x3 options) 70 MHz, 100 MHz, 200 MHz, 300 MHz
Rise time R&S®RTB 22/24 (with R&S®RTB-B2x1, R&S®RTB-B2x2 and R&S®RTB-B2x3 options) 5 ns, 3.5 ns, 1.75 ns, 1.15 ns
Input impedance 1 MΩ ± 2% with 9 pF ± 2 pF (meas.)
Input sensitivity Max. bandwidth in all ranges 1 mV/div to 5 V/div
ADC resolution 10 bit, up to 16 bit with high resolution decimation
DC gain accuracy offset and position = 0, maximum operating temperature change of ±5°C after self-alignment input sensitivity > 5 mV/div: ± 1.5% of full scale
input sensitivity ≤ 5 mV/div: ± 2% of full scale
Acquisition system
Real-time sampling rate 1.25 Gsample/s; 2.5 Gsample/s, interleaved
Acquisition memory standard 10 Msample; 20 Msample, interleaved;
160 Msample segmented memory
Max. acquisition rate 50 000 waveforms/s
(300 000 in fast segmented memory mode)
Horizontal system
Timebase range selectable between 1 ns/div and 500 s/div
Accuracy (after delivery/calibration) ±2.5 ppm
Channel-to-channel skew max. 800 ps (meas.)
Channel deskew ±500 ns
Trigger system
Standard trigger types edge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p), pattern, line, serial bus
Optional trigger types I2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN
Trigger sensitivity with DC, AC, LF reject input sensitivity > 5 mV/div: < 0.8 div (meas.);
2 mV/div ≤ input sensitivity < 5 mV/div: < 1.5 div (meas.);
input sensitivity < 2 mV/div: < 2 div (meas.)
with HF reject all input sensitivities < 1 div (meas.)
Analysis and measurement functions
Automatic measurements  32
Cursor measurements 4
Waveform mathematics  5 equations math on math (addition, subtraction, multiplication, division, square, square root, abs. value, reciprocal, inverse, common log., natural log., derivative, integral, low pass, track unipolar + bipolar on period, frequency, pulse width, duty cycle) 
Mask testing
Mask definition elementary (tolerance mask around the signal)
History and segmented memory
Number of segments up to 13 107
Protocol trigger and decode
Supported protocols I2C, SPI, UART/RS-232/ RS-422/RS-485, CAN, LIN
Waveform generator
Resolution 14-bit
Sample rate 250 Mpoint/s
Amplitude high-Z; 50 Ω 20 mV to 5 V (Vpp); 10 mV to 2.5 V (Vpp)
DC offset high-Z; 50 Ω ±2.5 V; ±1.25 V
Arbitrary sampling rate; memory depth max. 10 Msample/s; 16k point
Logic analyzer (MSO) functionality
Digital input channels 16
MSO memory depth 10 Msample for every channel
MSO Bandwidth 300 MHz (meas.)
MSO sampling rate 1.25 Gsample/s
MSO input impedance 100 kΩ ± 2 % || ~4 pF (meas.) at probe tips
Parallel buses up to 2
General data
Dimensions W × H × D 390  mm × 220 mm × 152 mm
(15.4 in × 8.66 in × 5.98 in)
Weight 2.5 kg (5.5 lb)
Display 10.1" WXGA TFT color display (1280 × 800 pixel)
Interfaces USB host with MTP, USB device, LAN, powerful web server for remote display and operation
Operating system Embedded

Available options

General
Product
Descrição
R&S®RTB2-B1

Order Number 1801.8421.02

Descrição

Mixed signal option for R&S®RTB 2 oscilloscope, 300 MHz

Enables up to 16 digital channels.

Passive probes
Product
Descrição

Order Number 1803.1001.02

Descrição

Passive probe, 300 MHz, 10:1

Order Number 1333.2401.02

Descrição

Passive probe, 500 MHz, 10:1

Order Number 1409.7550.00

Descrição

Passive probe, 500 MHz, 10:1

Order Number 1333.1370.02

Descrição

Passive probe, 38 MHz, 1:1

High voltage probes
Product
Descrição

Order Number 1333.0873.02

Descrição

250 MHz passive high voltage probe

Order Number 1409.7720.02

Descrição

400 MHz passive high voltage probe

Order Number 1409.7737.02

Descrição

400 MHz passive high voltage probe

Logic probes
Product
Descrição
R&S®RT-ZL03

Order Number 1333.0715.02

Descrição

300 MHz logic probe, 8 channels

Probe accessories
Product
Descrição

Order Number 1333.0850.02

Descrição

AC/DC 20 kHz current probe

Order Number 1333.0844.02

Descrição

100 kHz current probe

Order Number 1409.7750K02

Descrição

10 MHZ current probe

Order Number 1409.7766K02

Descrição

100 MHZ current probe

Order Number 1409.7772K02

Descrição

120 MHz current probe

Order Number 1801.4932.02

Descrição

120 MHz current probe

Order Number 1409.7789.02

Descrição

Power supply for probes

Power supply for R&S®RT-ZC10/20/30/31 probes, +/-12V DC, +/-2.5A

Application bundles
Product
Descrição
R&S®RTB2-PK1

Order Number 1801.8438.02

Descrição

Application bundle (R&S®RTB-K1, -K2, -K3 and -K36)

Application bundle contains triggering and decoding I²C/SPI (R&S®RTB-K1), UART/RS-232/RS-422/RS-485 (R&S®RTB-K2), CAN/LIN (R&S®RTB-K3) and frequency response analysis (R&S®RTB-K36)

General
Product
Descrição
R&S®RTB-Z1

Order Number 1333.1728.02

Descrição

Front cover

Protects the front of the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000

R&S®RTB-Z4

Order Number 1335.9290.02

Descrição

Transit case with wheels for R&S®RTB

R&S®RTB-Z3

Order Number 1333.1734.02

Descrição

Soft bag

Stores the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 oscilloscope and accessories

R&S®ZZA-RTB2K

Order Number 1333.1711.02

Descrição

19" rackmount adapter for R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 with 5HU

Order Number 1335.7875.02

Descrição

Accessory case for probes and small parts for all Rohde and Schwarz oscilloscopes

Peça informações

Você tem alguma pergunta ou precisa de informação adicional? Simplesmente preencha este formulário e nós respondemos imediatamente.

Licença de marketing

O seu pedido foi submetido. Iremos contactá-lo em breve.
An error is occurred, please try it again later.
Informações gerais e legais

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termos e condições do sorteio de prêmios: 10 anos dos osciloscópios da Rohde & Schwarz

1. O sorteio de prêmios “10 anos dos osciloscópios da Rohde & Schwarz” (no presente, referido como “Sorteio”) é organizado pela Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munique, Alemanha, tel. +49 89 41 29 0 (doravante referida como “R&S”).

2. Todos os participantes podem se inscrever durante o período de 1º de janeiro de 2020 a 31 de dezembro de 2020, informando seu nome, nome da empresa e e-mail comercial.

3. A participação é gratuita e não depende da compra de mercadorias ou serviços.

4. O sorteio está aberto somente a pessoas jurídicas e apenas às pessoas jurídicas que possam ganhar os prêmios. Pessoas físicas não poderão participar em nome e interesse próprios, mas como representantes de uma pessoa jurídica, devendo preencher a ficha de participação em nome e segundo o interesse da pessoa jurídica.

5. Os prêmios a serem entregues são 1 de 10 R&S®RTB2000, no período de 1º de janeiro de 2020 a 31 de dezembro de 2020:

Prêmio: 1 osciloscópio digital R&S®RTB2000

6. O sorteio ocorrerá na sede da R&S, em Munique, à Muehldorstrasse 15, 81671. O ganhador dos prêmios será avisado por e-mail no prazo de cinco (5) dias úteis.

7. O representante autorizado da pessoa jurídica informará à R&S sobre a aceitação do preço. Caso a aceitação seja negada ou se não houver resposta em até duas (2) semanas, um novo ganhador será sorteado. Se não for possível definir um ganhador no prazo de quatro (4) semanas, o sorteio se encerrará e o prêmio prescreverá.

8. Aos funcionários da R&S e seus familiares, bem como às pessoas familiarizadas com o processo do sorteio e seus familiares, é vetado o preenchimento da ficha de participação.

9. Não são permitidos equivalente em dinheiro ou troca de prêmios. Os prêmios são intransferíveis. Todos os impostos, tributos, encargos, taxas e outras cobranças tributáveis no país do participante serão arcadas pelo participante.

10. Dados pessoais somente serão processados para os fins deste sorteio e excluídos quatro (4) semanas após o sorteio, se não acordado de outro modo.

11. O participante que não cumprir os presentes Termos e Condições estará sujeito à desclassificação pela R&S da participação neste concurso. Neste caso, os prêmios também poderão ser retirados retroativamente. Se um prêmio estiver sujeito à retirada retrospectiva por motivo de incumprimento dos presentes Termos e Condições, ele deverá ser devolvido pelo respectivo participante, às suas expensas, para o endereço da R&S mencionado na disposição N.1, e um novo ganhador será sorteado.

12. Os participantes não podem reivindicar os prêmios do sorteio e não são autorizados recursos legais neste sentido.

13. O sorteio e a relação contratual decorrente, entre a R&S e o respectivo participante, serão regidos e interpretados de acordo com as leis da Alemanha, sem dar efeito ao princípio do conflito de leis. Os tribunais de Munique, Alemanha, gozarão de jurisdição exclusiva em caso de disputa decorrente, direta ou indiretamente, da participação neste concurso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.