Key Facts

  • Bandwidth: 70 MHz to 300 MHz
  • Sample rate: up to 2.5 Gsample/s
  • Memory depth: up to 20 Msample
  • ADC resolution: 10 bit
  • Display: 10.1" capacitive touchscreen

Power of ten for every task, everyday

The R&S®RTB 2 series oscilloscopes combine the power of ten with smart operating concepts, making them the ideal all-purpose tool for students, hobbyists, technicians and engineers. As a successor to the highly capable R&S®RTB2000, the R&S®RTB 2 series features a 10-bit ADC, 10 Msample memory, and a 10.1-inch touchscreen.

Additionally, the R&S®RTB 2 series includes an integrated arbitrary waveform generator history and segmented memory capabilities. Furthermore, all RTB 2 models are MSO-ready, allowing the use of up to 16 digital channels with the appropriate probes.

These oscilloscopes offer four times the vertical resolution of standard 8-bit ADCs while maintaining fast sampling rates at all times. With the largest display and highest resolution in their class, they provide extensive capabilities for university laboratories, troubleshooting embedded designs during development, and for production and service departments.

The R&S®RTB 2 series is the perfect solution for anyone needing precise and reliable measurements.

Features & benefits

Signal analysis: quick results

See small signal details in the presence of large signals

The R&S®RTB 2 features a customized Rohde & Schwarz engineered 10-bit A/D converter that delivers a fourfold improvement compared to conventional 8-bit A/D converters. The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltage across the switching device must be determined during the on/off times within the same acquisition.

10-bit A/D converter
Mostrar mais detalhes

10-bit A/D converter

The Rohde & Schwarz designed 10-bit A/D converter ensures the highest signal fidelity at the highest resolution.

Capture more time at full bandwidth

10 Msample standard and 20 Msample interleaved

The R&S®RTB 2 offers a class-leading memory depth: 10 Msample per channel are available, even 20 Msample in interleaved mode. This is 10 times more than similar oscilloscopes in the same instrument class. The user captures longer acquisition sequences even at high sampling rates, e.g. when analyzing transients of switched-mode power supplies, and thus benefits from more detailed analysis results.

10 Msample standard memory
Mostrar mais detalhes

10 Msample standard memory

Capture and analyze pulsed and burst signals over a long period with up to 20 Msample standard acquisition memory.

Segmented memory

160 Msample with history function

Every R&S®RTB 2 is equipped with a standard segmented memory functionality. Protocol-based signals with communications gaps such as I²C or SPI can be captured over several seconds or minutes. The variable segment size optimally utilizes the 160 Msample memory. In history mode, previous acquisitions in the maximum segmented memory depth of 160 Msample are available for further analysis.

160 Mpoint segmented memory
Mostrar mais detalhes

160 Mpoint segmented memory

Capture the longest time periods with class-leading 160 Msample memory.

Logic analysis with the MSO option

16 additional digital channels

Every R&S®RTB 2 is MSO ready, which allows the R&S®RTB2-B1 option to enable up to 16 additional digital channels. The oscilloscope captures and analyzes signals from analog and digital components of an embedded design – synchronously and time-correlated to each other. For example, the delay between A/D converter input and output can conveniently be determined with the cursor measurements.

Four-bit DAC signal change.
Mostrar mais detalhes

Four-bit DAC signal change.

The R&S®RTB 2 captures and analyzes analog and digital signals synchronously and in time-correlated to each other.

Waveform and pattern generator

Generate analog and digital stimuli

The R&S®RTB-B6 waveform and pattern generator up to 50 Mbit/s is useful for educational purposes and for implementing prototype hardware. Apart from the common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Predefined patterns including. I2C, SPI, UART and CAN/LIN can be used.

Waveform and pattern generator
Mostrar mais detalhes

Waveform and pattern generator

In addition to common sine, square/pulse, ramp and noise waveforms, it outputs user-defined waveforms and 4-bit signal patterns.

Digital voltmeter

Measure and display electrical potential

The R&S®RTB 2 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel for simultaneous measurements. Standard measurement functions include DC, AC+DC (RMS) and AC (RMS).

Digital voltmeter
Mostrar mais detalhes

Digital voltmeter

The 3-digit voltmeter measures and displays the electrical potential difference between two points in an electric circuit.

Frequency analysis mode

Difficult-to-find faults often result from the interaction between time and frequency signals. The FFT function of the R&S®RTB 2 is activated at the push of a button and by simply entering the center frequency and span. Thanks to the R&S®RTB 2 oscilloscopes’ high-performance FFT functionality, signals can be analyzed with up to 128 kpoints. Other practical tools include cursor measurements and autoset in frequency domain.

Frequency analysis mode
Mostrar mais detalhes

Frequency analysis mode

The high-performance FFT functionality analyzes signals up to 128 kpoints.

Mask test mode

Mask tests quickly reveal whether a specific signal lies within defined tolerance limits. By using statistical pass/fail evaluation, they assess quality and stability of a DUT. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation can generate a pulse output at the AUX-OUT connector on the R&S®RTB 2. This pulse output can be used to trigger actions in the measurement setup.

Mask test with result statistics
Mostrar mais detalhes

Mask test with result statistics

The pass/fail evaluation assesses DUT quality and stability.

Ready for the teaching lab

In the teaching lab, the R&S®RTB 2 oscilloscope is the perfect choice to teach students how to measure with an oscilloscope. It has an easy-to-use concept combined with state-of-the-art technology at an affordable price. The large 10.1" high-resolution screen shows every signal detail, and one instrument can be shared among several students. Reports can be efficiently created with the handy, flexible screen annotation tool.

Ready for the teaching lab
Mostrar mais detalhes

Ready for the teaching lab

Perfect instruments for everyday use at universities and colleges thanks to diverse functionality, rugged design and a small footprint.

Available models

Available options

Peça informações

Você tem alguma pergunta ou precisa de informação adicional? Simplesmente preencha este formulário e nós respondemos imediatamente.

Licença de marketing

O seu pedido foi submetido. Iremos contactá-lo em breve.
An error is occurred, please try it again later.
Informações gerais e legais

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termos e condições do sorteio de prêmios: 10 anos dos osciloscópios da Rohde & Schwarz

1. O sorteio de prêmios “10 anos dos osciloscópios da Rohde & Schwarz” (no presente, referido como “Sorteio”) é organizado pela Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munique, Alemanha, tel. +49 89 41 29 0 (doravante referida como “R&S”).

2. Todos os participantes podem se inscrever durante o período de 1º de janeiro de 2020 a 31 de dezembro de 2020, informando seu nome, nome da empresa e e-mail comercial.

3. A participação é gratuita e não depende da compra de mercadorias ou serviços.

4. O sorteio está aberto somente a pessoas jurídicas e apenas às pessoas jurídicas que possam ganhar os prêmios. Pessoas físicas não poderão participar em nome e interesse próprios, mas como representantes de uma pessoa jurídica, devendo preencher a ficha de participação em nome e segundo o interesse da pessoa jurídica.

5. Os prêmios a serem entregues são 1 de 10 R&S®RTB2000, no período de 1º de janeiro de 2020 a 31 de dezembro de 2020:

Prêmio: 1 osciloscópio digital R&S®RTB2000

6. O sorteio ocorrerá na sede da R&S, em Munique, à Muehldorstrasse 15, 81671. O ganhador dos prêmios será avisado por e-mail no prazo de cinco (5) dias úteis.

7. O representante autorizado da pessoa jurídica informará à R&S sobre a aceitação do preço. Caso a aceitação seja negada ou se não houver resposta em até duas (2) semanas, um novo ganhador será sorteado. Se não for possível definir um ganhador no prazo de quatro (4) semanas, o sorteio se encerrará e o prêmio prescreverá.

8. Aos funcionários da R&S e seus familiares, bem como às pessoas familiarizadas com o processo do sorteio e seus familiares, é vetado o preenchimento da ficha de participação.

9. Não são permitidos equivalente em dinheiro ou troca de prêmios. Os prêmios são intransferíveis. Todos os impostos, tributos, encargos, taxas e outras cobranças tributáveis no país do participante serão arcadas pelo participante.

10. Dados pessoais somente serão processados para os fins deste sorteio e excluídos quatro (4) semanas após o sorteio, se não acordado de outro modo.

11. O participante que não cumprir os presentes Termos e Condições estará sujeito à desclassificação pela R&S da participação neste concurso. Neste caso, os prêmios também poderão ser retirados retroativamente. Se um prêmio estiver sujeito à retirada retrospectiva por motivo de incumprimento dos presentes Termos e Condições, ele deverá ser devolvido pelo respectivo participante, às suas expensas, para o endereço da R&S mencionado na disposição N.1, e um novo ganhador será sorteado.

12. Os participantes não podem reivindicar os prêmios do sorteio e não são autorizados recursos legais neste sentido.

13. O sorteio e a relação contratual decorrente, entre a R&S e o respectivo participante, serão regidos e interpretados de acordo com as leis da Alemanha, sem dar efeito ao princípio do conflito de leis. Os tribunais de Munique, Alemanha, gozarão de jurisdição exclusiva em caso de disputa decorrente, direta ou indiretamente, da participação neste concurso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.