Key Facts
- Bandwidth: 50 MHz to 300 MHz
- Max. sample rate: 2 Gsample/s
- Max. memory depth: 2 Msample
- MSO: 8 digital channels, optional, retrofittable
- Pattern generator: 4-bit patterns up to 50 Mbit/s
Key Facts
High sensitivity, multifunctionality and a great price - that is what makes the R&S®RTC1000 oscilloscope so special. From embedded developers to service technicians to educators - the wide range of functions address a broad group of users. State-of-the-art, high-performance technology in a fanless design meets the high requirements of today's customers.
Quick Links
Top-class hardware-based acquisition for precise measurement results
With a sampling rate of up to 2 Gsample/s and a memory depth of up to 2 Msample, the R&S®RTC1000 oscilloscope excels in its class. A waveform update rate of more than 10 000 waveforms/s ensures a responsive instrument that reliably catches signal faults. Included tools provide quick results, e.g. QuickMeas, mask tests, FFT, math, cursors and automatic measurements (including statistics).
The R&S®RTC1000 provides top-class hardware based acquisition for precise measurement results
QuickView: key results at the push of a button
Versatile measurement functions
QuickView: key results at the push of a button
Eight additional digital channels
The R&S®RTC-B1 option turns every R&S®RTC1000 into an intuitive-to-use MSO with eight additional digital channels. The oscilloscope captures and analyzes signals from analog and digital components in an embedded design - synchronously and time-correlated to each other. For example, the delay between the input and output of an A/D converter can be conveniently determined using the cursor measurements.
8-bit DAC signal change
The R&S®RTC1000 captures and analyzes analog and digital signals synchronously and time-correlated to each other
Hardware- based trigggering and decoding
Protocols such as I²C, SPI and CAN/LIN frequently transfer control messages between integrated circuits. The R&S®RTC1000 has versatile options for protocol- specific triggering and decoding of serial interfaces. Selective acquisition and analysis of relevant events and data is possible. With the hardware-based implementation, smooth operation and a high update rate are ensured even for long acquisitions. This is advantageous, for example, for capturing multiple packetized serial bus signals.
Hardware- based trigggering and decoding
Support for triggering and decoding of I²C, of 2-wire, 3-wire SPI buses. You can setup decoding in seconds
Measure and display electrical potential
For simultaneous measurements, the R&S®RTC1000 features a three-digit digital voltmeter (DVM) and six-digit frequency counter on each channel. Provided measurement functions include DC, AC + DC (RMS) and AC (RMS).
Voltmeter measurements using an oscilloscope
Generate analog and digital stimuli
The integrated R&S®RTC-B6 waveform and pattern generator up to 50 Mbit/s is useful for educational purposes and for implementing prototype hardware. In addition to common sine, square/pulse, ramp and noise waveforms, it outputs 4-bit patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. You can preview signals before playing them back to quickly check signal correctness. Predefined patterns for e.g. I2C, SPI, UART and CAN/LIN are provided.
Waveform and pattern generator
In addition to common sine, square/pulse, ramp and noise waveforms, it outputs pre- and user-defined 4-bit signal patterns
Determining current-voltage characteristics with the oscilloscope
You will also benefit from the included component tester. A 50 Hz and a 200 Hz measuring frequency are provided to support your potentially tedious search for faulty components. And since a picture says more than a thousand words - or rather a thousand values - you will be able to tell at a glance if your error analysis is on track.
Component tester
Charactersitic of a Zener diode with approx. 5 V breakdown voltage
Order Number 1335.7500P02
Order Number 1335.7500P72
Order Number 1335.7500P12
Order Number 1335.7500P22
Order Number 1335.7500P32
Vertical system | ||
Analog channels | 2 | |
Digital channels (opt.) | 8 | |
Bandwidth (-3 dB) | R&S®RTC1002 (with R&S®RTC-B220/-B221/-B222/-B223) | 50 MHz, 70 MHz, 100 MHz, 200 MHz, 300 MHz |
Rise time | R&S®RTC1002 R&S®RTC-B220/-B221/-B222/-B223) | 7 ns, 5 ns, 3.5 ns, 1.75 ns, 1.15 ns |
Input impedance | 1 MΩ ± 2% || 14 pF ± 2 pF | |
Input sensitivity | max. bandwidth in all ranges | 1 mV/div to 10 V/div |
ADC resolution | 8 bit, up to 16 bit with high resolution-decimation mode | |
DC gain accuracy | offset and position = 0, maximum operating temperature change of ±5°C after self-alignment | input sensitivity all ranges: 3 % |
Acquisition system | ||
Realtime sampling rate | 1 Gsample/s; 2 Gsample interleaved | |
Acquisition memory | 1 Msample; 2 Msample interleaved | |
Max. acquisition rate | 10 000 waveforms/s | |
Horizontal system | ||
Timebase range | 1 ns/div to 100 s/div | |
Accuracy (after delivery/calibration) | ±50 ppm | |
Channel-to-channel skew | max. 1 ns (meas.) | |
Channel deskew | ±120 ns | |
Trigger system | ||
Standard Trigger types | edge, width, video (PAL, SECAM, PAL-M, SDTV, HDTV) pattern, timeout | |
Optional Trigger types | I2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN | |
Trigger sensitivity | with DC, AC, LF reject input sensitivity ≥ 5 mV/div: < 0.8 div (meas.) input sensitivity < 5 mV/div: < 1.5 div (meas.) with HF reject all input sensitivities: < 1 div (meas.) with noise rejection input sensitivity > 5 mV/div: < 1.5 div (meas.) | |
Analysis and measurement functions | ||
Automatic measurements | 31 | |
Cursor measurements | 13 | |
Waveform mathematics | addition, subtraction, multiplication, division, FFT | |
Mask testing | ||
Mask definition | elementary (tolerance mask around the signal) | |
Protocol trigger and decode | ||
Supported protocols | I2C, SPI, UART/RS-232/ RS-422/RS-485, CAN, LIN | |
Waveform generator | ||
Resolution | 8 bit | |
Sample rate | 978 ksample/s | |
Amplitude | high Z; 50 Ω | 60 mV to 6 V (Vpp); 30 mV to 3 V (Vpp) |
DC offset | sine: 0.1 Hz to 50 kHz pulse/rectangle and ramp/triangle: 0.1 Hz to 10 kHz |
|
Logic analyzer (MSO) functionality | ||
Digital input channels | 8 | |
MSO Memory depth | 1 Msample for every channel | |
MSO Bandwidth | 300 MHz (meas.) | |
MSO sampling rate | 1 Gsample/s | |
MSO input impedance | 100 kΩ ± 2 % || ~4 pF (meas.) at probe tips | |
Parallel buses | up to 2 | |
General data | ||
Dimensions | W x H x D | 285 mm × 175 mm × 140 mm (11.22 in × 6.89 in × 5.51 in) |
Weight | 1.7 kg (3.75 lb) | |
Display | 6.5" VGA color display (640 × 480 pixel) | |
Interfaces | 1 x USB host, USB device, LAN | |
Operating system | Embedded |
Order Number 1335.7281.03
Mixed signal upgrade for non-MSO-models, 300 MHz
Turns the R&S®RTC1002 oscilloscopes into fast, precise and easy-to-use mixed signal oscilloscopes (MSO).
Order Number 1335.7298.03
Waveform generator
Adds a 50 kHz signal generator and a 4-bit pattern generator to your R&S®RTC1002 oscilloscopes.
Order Number 1335.7300.03
Bandwidth upgrade of the R&S®RTC1002 to 70 MHz bandwidth
Order Number 1335.7317.03
Bandwidth upgrade of the R&S®RTC1002 to 100 MHz bandwidth
Order Number 1335.7275.03
Bandwidth upgrade of the R&S®RTC1002 to 200 MHz bandwidth
Order Number 1335.7323.03
Bandwidth upgrade of the R&S®RTC1002 to 300 MHz bandwidth
Order Number 1335.7230.03
I²C/SPI serial triggering and decoding
Triggering and decoding of I²C and 2-wire, 3-wire or 4-wire SPI buses
Order Number 1335.7246.03
UART/RS-232/RS-422/RS-485 serial triggering and decoding
Triggering and decoding of UART based protocols and RS-232, RS-422 as well as RS-485 buses
Order Number 1335.7252.03
CAN/LIN serial triggering and decoding
Triggering and decoding of CAN and LIN interfaces
Order Number 1333.0867.02
Soft case
Stores the R&S®RTC1002 oscilloscope and accessories.
Order Number 1335.7875.02
Accessory case for probes and small parts for all Rohde and Schwarz oscilloscopes
Order Number 1333.0967.02
19" rackmount adapter for R&S®RTC1000 with 4HU
Order Number 1803.1001.02
Passive probe, 300 MHz, 10:1
Order Number 1333.2401.02
Passive probe, 500 MHz, 10:1
Order Number 1333.1370.02
Passive probe, 38 MHz, 1:1
Order Number 1333.0873.02
250 MHz passive high voltage probe
Order Number 1409.7720.02
400 MHz passive high voltage probe
Order Number 1409.7737.02
400 MHz passive high voltage probe
Order Number 1333.0850.02
AC/DC 20 kHz current probe
Order Number 1333.0844.02
100 kHz current probe
Order Number 1409.7750K02
10 MHZ current probe
Order Number 1409.7766K02
100 MHZ current probe
Order Number 1409.7772K02
120 MHz current probe
Order Number 1801.4932.02
120 MHz current probe
Order Number 1333.0715.02
300 MHz logic probe, 8 channels
Order Number 1409.7789.02
Power supply for probes
Power supply for R&S®RT-ZC10/20/30/31 probes, +/-12V DC, +/-2.5A
Order Number 1335.7330.03
Application bundle (R&S®RTC-K1, -K2, -K3 and -B6)
Application bundle contains I²C/SPI (R&S®RTC-K1), UART/RS-232(RS-422/RS-485 (RTC-K2) and CAN/LIN (RTC-K3), Generator (R&S®RTC-B6) for R&S®RTC1002 models
Produtos relacionados
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found
Termos e condições do sorteio de prêmios: 10 anos dos osciloscópios da Rohde & Schwarz
1. O sorteio de prêmios “10 anos dos osciloscópios da Rohde & Schwarz” (no presente, referido como “Sorteio”) é organizado pela Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munique, Alemanha, tel. +49 89 41 29 0 (doravante referida como “R&S”).
2. Todos os participantes podem se inscrever durante o período de 1º de janeiro de 2020 a 31 de dezembro de 2020, informando seu nome, nome da empresa e e-mail comercial.
3. A participação é gratuita e não depende da compra de mercadorias ou serviços.
4. O sorteio está aberto somente a pessoas jurídicas e apenas às pessoas jurídicas que possam ganhar os prêmios. Pessoas físicas não poderão participar em nome e interesse próprios, mas como representantes de uma pessoa jurídica, devendo preencher a ficha de participação em nome e segundo o interesse da pessoa jurídica.
5. Os prêmios a serem entregues são 1 de 10 R&S®RTB2000, no período de 1º de janeiro de 2020 a 31 de dezembro de 2020:
Prêmio: 1 osciloscópio digital R&S®RTB2000
6. O sorteio ocorrerá na sede da R&S, em Munique, à Muehldorstrasse 15, 81671. O ganhador dos prêmios será avisado por e-mail no prazo de cinco (5) dias úteis.
7. O representante autorizado da pessoa jurídica informará à R&S sobre a aceitação do preço. Caso a aceitação seja negada ou se não houver resposta em até duas (2) semanas, um novo ganhador será sorteado. Se não for possível definir um ganhador no prazo de quatro (4) semanas, o sorteio se encerrará e o prêmio prescreverá.
8. Aos funcionários da R&S e seus familiares, bem como às pessoas familiarizadas com o processo do sorteio e seus familiares, é vetado o preenchimento da ficha de participação.
9. Não são permitidos equivalente em dinheiro ou troca de prêmios. Os prêmios são intransferíveis. Todos os impostos, tributos, encargos, taxas e outras cobranças tributáveis no país do participante serão arcadas pelo participante.
10. Dados pessoais somente serão processados para os fins deste sorteio e excluídos quatro (4) semanas após o sorteio, se não acordado de outro modo.
11. O participante que não cumprir os presentes Termos e Condições estará sujeito à desclassificação pela R&S da participação neste concurso. Neste caso, os prêmios também poderão ser retirados retroativamente. Se um prêmio estiver sujeito à retirada retrospectiva por motivo de incumprimento dos presentes Termos e Condições, ele deverá ser devolvido pelo respectivo participante, às suas expensas, para o endereço da R&S mencionado na disposição N.1, e um novo ganhador será sorteado.
12. Os participantes não podem reivindicar os prêmios do sorteio e não são autorizados recursos legais neste sentido.
13. O sorteio e a relação contratual decorrente, entre a R&S e o respectivo participante, serão regidos e interpretados de acordo com as leis da Alemanha, sem dar efeito ao princípio do conflito de leis. Os tribunais de Munique, Alemanha, gozarão de jurisdição exclusiva em caso de disputa decorrente, direta ou indiretamente, da participação neste concurso.
* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.