Key Facts

  • Testing from 5 kHz up to 7.125 GHz
  • Precompliance and compliance testing
  • Flexible option concept – buy what you need, upgrade at any time
  • Fast time domain scan
  • Battery operation for mains independent use

Perfect for quick and precise EMI measurements

For precompliance and compliance applications from 5 kHz up to 7.125 GHz

The R&S®EPL1000 is specially designed for conducted measurements up to 30 MHz. Even the base unit offers time domain scan and preselection with preamplifier and fully complies with CISPR 16-1-1. For flexible pricing, these features are optionally available for the R&S®EPL1001 and R&S®EPL1007 which measure up to 1 GHz/7.125 GHz. All models automatically perform EMI measurements over several individually defined frequency ranges. Results are easily saved and printed. The R&S®EPL also offers in-depth analysis functions including a real-time spectrogram and four-channel click rate analysis. Battery operation, 12 V to 24 V DC input, a carrying bag and other extras enable very flexible deployment of the R&S®EPL.

Features & benefits

For all use cases

Up to CISPR 16-1-1 compliance

The R&S®EPL can be used both during the development phase and for certification. Provided RF and CISPR 16-1-1 relevant features include:

  • Hardware protection and attenuation of strong signals
  • Automatic use of full dynamic range and overload handling 
  • EMI bandwidths and detectors
With R&S®EPL1-B2 (included in R&S®EPL1000):
  • Improved measurement of broadband interferers and short pulses
  • Measurement of small signals
With R&S®EPL1-B1611 (included in R&S®EPL1000):
  • Full CISPR 16-1-1 compliance

Configuration and display of RF signal handling
Abrir o Lightbox

Configuration and display of RF signal handling

Time domain scan

Fast measurement with time domain scan

Using RBWs as defined by CISPR, the R&S®EPL can measure an entire CISPR band A or B in a single measurement. Frequency ranges above 30 MHz are measured automatically in multiple steps of 20 MHz using CISPR band associated RBWs. Up to three traces can be activated with different detectors, including CISPR detectors. This enables fast standard-compliant EMI measurements directly with the detector required by the standard.

Illustration of the TDS segment width
Abrir o Lightbox

Illustration of the TDS segment width

Convenient measurements

Strong features simplify the execution and documentation of EMI measurements

  • Automatic measurement of multiple frequency segments with individual settings (scan table)
  • Automated sequence of preview measurement, peak search and final measurement
  • Limit line display and checking to easily evaluate measurement results
  • Report generation to easily record, document and exchange results
  • Transducer factors to include characteristics of additional components used

Automatic measurement example
Abrir o Lightbox

Automatic measurement example

Measurement of A and B bands for neutral and live lines.

EMI analysis

The extensive analysis features include

  • Four-channel click rate analysis
  • Bar graph – level at a frequency
  • Real-time spectrogram – level versus frequency and time
  • Zero span – level at a frequency versus time
  • IF analysis
  • AM/FM output
  • Spectrum analysis functions

Measurement example with spectrogram
Abrir o Lightbox

Measurement example with spectrogram

Visualization of different EUT operating modes

Available models

Available models
Modelos
Frequency range

R&S®EPL1000

Order Number 1350.4444.10

Frequency range
5 kHz to 30 MHz

R&S®EPL1001

Order Number 1350.4444.11

Frequency range
5 kHz to 1 GHz; upgradeable to 7.125 GHz

R&S®EPL1007

Order Number 1350.4444.17

Frequency range
5 kHz to 7.125 GHz

Available options

Hardware options
Product
Descrição
R&S®EPL1-B2

Order Number 1350.4015.02

Descrição

Preselection with preamplifier

R&S®FPL1-B4

Order Number 1323.1902.02

Descrição

OCXO accurate reference frequency

High precision frequency reference

R&S®FPL1-B10

Order Number 1323.1890.02

Descrição

GPIB interface

Additional interface for remote control by GPIB, plug-in unit

R&S®FPL1-B30

Order Number 1323.1877.02

Descrição

DC Power supply for 12/24 V supply

R&S®FPL1-B31

Order Number 1323.1725.02

Descrição

Li-Ion battery pack

R&S®EPL1-B91

Order Number 1350.4073.02

Descrição

Internal generator 5 kHz to 30 MHz

Software options
Product
Descrição
R&S®EPL1-B9

Order Number 1350.4467.02

Descrição

Internal generator 5 kHz to 1 GHz

R&S®EPL1-B9

Order Number 1350.4044.02

Descrição

Internal generator 5 kHz to 7.125 GHz

R&S®EPL1-B22

Order Number 1350.4480.02

Descrição

Low-noise preamplifier 2 MHz to 1 GHz/7.125 GHz

R&S®EPL1-B1611

Order Number 1350.4515.02

Descrição

CISPR 16-1-1 compliance

R&S®EPL1-K53

Order Number 1350.4050.02

Descrição

Time domain scan

R&S®EPL1-K55E

Order Number 1350.4473.02

Descrição

Real-time spectrogram

R&S®EPL1-K56

Order Number 1350.4067.02

Descrição

IF analysis

R&S®EPL1-K59

Order Number 1350.4509.02

Descrição

4-channel click rate analyzer

CISPR 14-1 ed. 6 and ed. 7 compliant software for 4 channel simultaneous gapless measurement for up to four hours.

R&S®FPL1-K7

Order Number 1323.1731.02

Descrição

AM/FM/PM analog modulation analysis

Modulation analysis for analog (AM, FM, PM) modulated single carrier signals
(for use with the R&S®ZNL, the R&S®ZNLx-B1 is required )

R&S®EPL1-B7125

Order Number 1350.4021.02

Descrição

Frequency upgrade 1 GHz to 7.125 GHz, only for delivered R&S®EPL1001

Accessories
Product
Descrição
R&S®EPL1-Z1

Order Number 1350.4296.02

Descrição

Protective hard cover

R&S®EPL1-Z2

Order Number 1350.4309.02

Descrição

Soft carrying bag for R&S®EPL1000

R&S®EPL1-Z2

Order Number 1353.6431.02

Descrição

Soft carrying bag for R&S®EPL1001/R&S®EPL1007

R&S®EPL1-Z3

Order Number 1350.4315.02

Descrição

H-style shoulder harness (requires R&S®EPL1-Z2 option)

R&S®FPL1-Z4

Order Number 1323.1677.02

Descrição

Spare battery pack

R&S®EPL1-Z6

Order Number 1350.4321.02

Descrição

19" rackmount kit for R&S®EPL1000

R&S®EPL1-Z6

Order Number 1353.6377.02

Descrição

19" rackmount kit for R&S®EPL1001/R&S®EPL1007

R&S®EPL1-B19

Order Number 1350.4450.02

Descrição

Replacement SSD including controller unit

R&S®FSV-B34

Order Number 1321.3950.02

Descrição

Charger for R&S®FSV-B32 lithium-ion battery pack

R&S®EZ-21

Order Number 1107.2087.03

Descrição

Control Cable, 3 m

from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL1000 and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200

R&S®EZ-21

Order Number 1107.2087.10

Descrição

Control Cable, 10 m

from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200 

R&S®DCV-2

Order Number 0240.2193.09

Descrição

Documentation of calibration values

Peça informações

Você tem alguma pergunta ou precisa de informação adicional? Simplesmente preencha este formulário e nós respondemos imediatamente.

Licença de marketing

O seu pedido foi submetido. Iremos contactá-lo em breve.
An error is occurred, please try it again later.
Informações gerais e legais

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termos e condições do sorteio de prêmios: 10 anos dos osciloscópios da Rohde & Schwarz

1. O sorteio de prêmios “10 anos dos osciloscópios da Rohde & Schwarz” (no presente, referido como “Sorteio”) é organizado pela Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munique, Alemanha, tel. +49 89 41 29 0 (doravante referida como “R&S”).

2. Todos os participantes podem se inscrever durante o período de 1º de janeiro de 2020 a 31 de dezembro de 2020, informando seu nome, nome da empresa e e-mail comercial.

3. A participação é gratuita e não depende da compra de mercadorias ou serviços.

4. O sorteio está aberto somente a pessoas jurídicas e apenas às pessoas jurídicas que possam ganhar os prêmios. Pessoas físicas não poderão participar em nome e interesse próprios, mas como representantes de uma pessoa jurídica, devendo preencher a ficha de participação em nome e segundo o interesse da pessoa jurídica.

5. Os prêmios a serem entregues são 1 de 10 R&S®RTB2000, no período de 1º de janeiro de 2020 a 31 de dezembro de 2020:

Prêmio: 1 osciloscópio digital R&S®RTB2000

6. O sorteio ocorrerá na sede da R&S, em Munique, à Muehldorstrasse 15, 81671. O ganhador dos prêmios será avisado por e-mail no prazo de cinco (5) dias úteis.

7. O representante autorizado da pessoa jurídica informará à R&S sobre a aceitação do preço. Caso a aceitação seja negada ou se não houver resposta em até duas (2) semanas, um novo ganhador será sorteado. Se não for possível definir um ganhador no prazo de quatro (4) semanas, o sorteio se encerrará e o prêmio prescreverá.

8. Aos funcionários da R&S e seus familiares, bem como às pessoas familiarizadas com o processo do sorteio e seus familiares, é vetado o preenchimento da ficha de participação.

9. Não são permitidos equivalente em dinheiro ou troca de prêmios. Os prêmios são intransferíveis. Todos os impostos, tributos, encargos, taxas e outras cobranças tributáveis no país do participante serão arcadas pelo participante.

10. Dados pessoais somente serão processados para os fins deste sorteio e excluídos quatro (4) semanas após o sorteio, se não acordado de outro modo.

11. O participante que não cumprir os presentes Termos e Condições estará sujeito à desclassificação pela R&S da participação neste concurso. Neste caso, os prêmios também poderão ser retirados retroativamente. Se um prêmio estiver sujeito à retirada retrospectiva por motivo de incumprimento dos presentes Termos e Condições, ele deverá ser devolvido pelo respectivo participante, às suas expensas, para o endereço da R&S mencionado na disposição N.1, e um novo ganhador será sorteado.

12. Os participantes não podem reivindicar os prêmios do sorteio e não são autorizados recursos legais neste sentido.

13. O sorteio e a relação contratual decorrente, entre a R&S e o respectivo participante, serão regidos e interpretados de acordo com as leis da Alemanha, sem dar efeito ao princípio do conflito de leis. Os tribunais de Munique, Alemanha, gozarão de jurisdição exclusiva em caso de disputa decorrente, direta ou indiretamente, da participação neste concurso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.