Key Facts
- 6 GHz maximum bandwidth
- 1 million waveforms per second
- 9.4 ENOB for ultimate signal integrity
- 2 Gpoints maximum memory
- Exclusive frequency zone trigger
Commençant à 39 300 CAD
Key Facts
Commençant à 39 300 CAD
The R&S®RTO6 is the oscilloscope you can trust. Engineered to deliver reliable results, it acts as a sophisticated laboratory companion to solve measurement problems fast and keep you on schedule. The R&S®RTO6 oscilloscope series leverages the engineer’s expertise and builds your measurement confidence by achieving deep insights, whenever needed.
The R&S®RTO6 oscilloscope series provides superior signals to insight for your applications. The large 15.6" touchscreen and a new GUI, combined with high waveform update rate, excellent signal fidelity, digital trigger and deep responsive memory serve as a fully integrated test solution for frequency, protocol and logic analysis. The R&S®RTO6 oscilloscope series’ rich measurement toolset combined with a streamlined user interface helps you quickly solve circuit issues from simple to complex.
Quick Links
... with an unparalleled update rate
Typical update rate (left) vs. 1 million waveforms/s (right)
... with excellent signal integrity
Measured frequency response of the R&S®RTO6
... with up to 16 bit resolution
Typical vertical resolution (left) vs. 16 bit resolution HD Mode (right)
... with advanced trigger capabilities
Trigger not possible (left) vs. straightforward triggering with digital trigger and HD Mode (right)
... with deep and responsive memory
Single-shot versus segmented acquisition
Vertical system | ||
Analog channels | 4 | |
Bandwidth (-3 dB) | R&S®RTO64 with R&S®RTO6-B90 option | 600 MHz |
(one bandwidth option mandatory) | R&S®RTO64 with R&S®RTO6-B91 option | 1 GHz |
R&S®RTO64 with R&S®RTO6-B92 option | 2 GHz | |
R&S®RTO64 with R&S®RTO6-B93 option | 3 GHz | |
R&S®RTO64 with R&S®RTO6-B94 option | 4 GHz | |
R&S®RTO64 with R&S®RTO6-B96 option | on 2 channels: 6 GHz on 4 channels: 4 GHz |
|
Rise time | R&S®RTO64 with R&S®RTO6-B90 option | 635 ps |
R&S®RTO64 with R&S®RTO6-B91 option | 375 ps | |
R&S®RTO64 with R&S®RTO6-B92 option | 210 ps | |
R&S®RTO64 with R&S®RTO6-B93 option | 145 ps | |
R&S®RTO64 with R&S®RTO6-B94 option | 110 ps | |
R&S®RTO64 with R&S®RTO6-B96 option | 77 ps | |
Vertical resolution | 16-bit system architecture | |
Effective number of bits / ENOB (meas.) | at 50 Ω, 50 mV/div, 10 MHz input signal with 90 % full-scale 50 MHz 100 MHz 200 MHz 300 MHz 500 MHz 1 GHz 2 GHz 4 GHz 6 GHz |
9.4 9.0 8.6 8.2 8.1 7.7 7.1 6 6 |
RMS noise floor | at 50 Ω, 1 mV/div, 10 MHz bandwidth filter | 10 µV (meas.) |
Input impedance | 50 Ω ±1.5 % 1 MΩ ±1 % at 15 pF (meas.) |
|
Input sensitivity | max. bandwidth in all ranges | 50 Ω: 1 mV/div to 1 V/div 1 MΩ: 1 mV/div to 10 V/div |
Acquisition system | ||
Realtime sampling rate | R&S®RTO6-B90, R&S®RTO6-B91, R&S®RTO6-B92, R&S®RTO6-B93 options | max 10 Gsample/s on each channel |
R&S®RTO6-B94, R&S®RTO6-B96 options | max. 10 Gsample/s on 4 channels max. 20 Gsample/s on 2 channels |
|
Acquisition memory | standard | 200 Mpoints on 4 channels 400 Mpoints on 2 channels 800 Mpoints on 1 channel |
R&S®RTO6-B104 option | 400 Mpoints on 4 channels 800 Mpoints on 2 channels 800 Mpoints on 1 channel |
|
R&S®RTO6-B110 option | 1 Gpoint on 4 channels 2 Gpoints on 2 channels (restriction: 1 Gpoint on 2 channels when channel 1 and channel 2 or channel 3 and channel 4 are turned on) 2 Gpoints on 1 channel |
|
Max. acquisition rate | 1 000 000 waveforms/s | |
Decimation modes | any combination of decimation mode and waveform arithmetics on up to 3 waveforms per channel | sample, peak detect, high resolution, root mean square |
Waveform arithmetics | off, envelope, average | |
Interpolation modes | linear, sin(x)/x, sample&hold | |
Deembedding (optional) | yes | |
Horizontal system | ||
Timebase range | 25 ps/div to 10,000 s/div | |
Timebase Accuracy | after delivery/calibration | ±10 ppb |
Trigger system | ||
Standard Trigger types | edge, glitch, width, runt, window, timeout, interval, slew rate, data2clock, pattern, state, serial pattern, TV/video, zone trigger | |
Optional Trigger types | serial bus trigger | |
Trigger sensitivity | definition of trigger hysteresis | automatic or manually adjustable from 0 div to 5 div |
Analysis and measurement | ||
Automatic measurements | 47 | |
Cursor measurements | 4 | |
Waveform mathematics | advanced (formula editor) | |
Mask testing | ||
Mask definition | advanced (user-configurable, hardware based) | |
Logic analyzer (MSO) functionality | ||
Digital input channels | 16 | |
MSO Memory depth | 200 Mpts per channel | |
MSO Bandwidth | 400 MHz | |
MSO sampling rate | 5 Gsample/s per channel | |
General data | ||
Dimensions | W x H x D | 450 mm × 315 mm × 204 mm (17.72 in × 12.40 in × 8.03 in) |
Weight | 10.7 kg (23.59 lb) | |
Interfaces | 1 Gbps LAN, type A: 2 x USB 3.1, 2 x USB 2.0, type B: 1 x USB 3.1, GPIB (optional), HDMI and DisplayPort for external monitor, external trigger, trigger output | |
Display | 15.6" capacitive touchscreen, resolution: 1920 x 1080 pixel (Full HD) | |
Operating system | Windows |
Numéro de commande 1801.6741.02
Mixed signal option: 16 digital channels, 5 GSa/s, 400 MHz bandwidth
Numéro de commande 1801.6735.02
Digital Extension Port for R&S®RTO6. Required for R&S®RT-ZVC02 and R&S®RT-ZVC04 Hardware. Included in R&S®RTO-B1.
Numéro de commande 1801.6758.02
Arbitrary waveform generator: 2-channel 500 MSample/s waveform generator and 8-channel pattern generator
Numéro de commande 1801.6829.02
Jitter analysis
Numéro de commande 1801.6835.02
Clock data recovery
Numéro de commande 1801.6858.02
Power analysis
Numéro de commande 1801.6870.02
Spectrum analysis
Numéro de commande 1801.6887.02
Deembedding for compensation of channel effects
Numéro de commande 1801.8109.02
Embedding & Equalization
Embedding user-configurable components, predistortion at TX and equalization at RX via CTLE, FFE or DFE
Numéro de commande 1801.6893.02
TDR/TDT analysis
Numéro de commande 1801.6906.02
Jitter decomposition: Decomposition of jitter components, display of step response, histograms, synthetic eye diagrams, spectrum and BER-bathtub curve
Numéro de commande 1801.7677.02
Jitter and noise decomposition
Numéro de commande 1801.8050.02
PAM-N Analysis
Enabled for advanced jitter & noise, advanced eye and selected automated time/amplitude and eye measurements.
Numéro de commande 1801.8080.02
Advanced Eye Analysis
Including SW-CDR and comprehensive Mask test library.
Numéro de commande 1801.6864.02
Bus analysis: Bus measurements and analysis functions
Numéro de commande 1801.7019.02
Trigger & decode package "Low speed serial buses": I2C, SPI, RS-232, UART, I2S, LJ, RJ, TDM, Manchester, NRZ
Numéro de commande 1801.7025.02
Trigger & decode package "Automotive protocols": CAN incl. CAN-dbc file import, CAN-FD, LIN, FlexRay™ incl.
Fibex file import, SENT, CXPI
Numéro de commande 1801.7031.02
Trigger & decode package "Aerospace protocols": MIL-STD-1553, ARINC 429, SpaceWire
Numéro de commande 1801.7048.02
Ethernet protocols trigger and decode package: 10BASE-T, 100BASE-TX, MDIO
Numéro de commande 1801.7054.02
Trigger & decode MIPI RFFE
Numéro de commande 1801.7060.02
Trigger & decode package "Automotive Ethernet": IEEE 100BASE-T1, IEEE 1000BASE-T1
Numéro de commande 1801.7077.02
Trigger & decode package "USB protocols": USB 1.0/1.1, USB 2.0/HSIC, USB 3.1 Gen 1, USB Power Delivery (USB-PD), USB SSIC
Numéro de commande 1801.7083.02
Trigger & decode package "MIPI M-PHY, D-PHY": MIPI D-PHY, MIPI M-PHY, UniPro, decoding for DSI und CSI-2
Numéro de commande 1801.7090.02
"PCI Express" trigger and decode package : 8b10b (up to 6.25 Gbit/s), PCI Express revision 1.x/2.x
Numéro de commande 1801.6912.02
USB 2.0 compliance test
Numéro de commande 1801.6929.02
10M/100M/1G-BASE-T/EE Ethernet compliance test
Numéro de commande 1801.6935.02
Ethernet compliance test (2.5/5/10GBASE-T)
Numéro de commande 1801.6941.02
IEEE 100BASE-T1 compliance test
Numéro de commande 1801.6958.02
MIPI-D-PHY compliance test
Numéro de commande 1803.6578.02
R&S®MIPI D-PHY compliance test software, V2.5
Numéro de commande 1801.6964.02
PCI Express 1.1/2.0 compliance test
Numéro de commande 1801.6970.02
IEEE 1000BASE-T1 compliance test
Numéro de commande 1801.6987.02
IEEE 10BASE-T1 compliance test
Numéro de commande 1801.7890.02
MGBASE-T1 compliance test
Numéro de commande 1801.6993.02
DDR3/DDR3L/LPDDR3 signal integrity debug and compliance test
Numéro de commande 1801.7160.02
eMMC compliance test
Numéro de commande 1801.7690.02
R&S®ScopeSuite automation
Numéro de commande 1801.6812.02
I/Q software interface: Converts modulated signals to I/Q data for further processing
Numéro de commande 1345.1011.06
Software
Brings the experience and power of Rohde & Schwarz signal analysis to PC and cloud
Numéro de commande 1310.0002K02
License dongle
Numéro de commande 1345.2230.06
Transient phase noise measurements
Numéro de commande 1345.1392.06
5G NR R16 measurements
Numéro de commande 1345.1463.06
HRP UWB measurements
Numéro de commande 1345.1663.02
5G NR R17 measurements
Numéro de commande 1350.7020.06
O-RAN measurements
Numéro de commande 1320.7622.81
Software maintenance
Numéro de commande 1800.0004.02
Power deskew fixture
Deskew fixture for voltage and current probes for power measurements; includes USB 2.0 cable for power supply
Numéro de commande 1409.7550.00
Passive probe, 500 MHz, 10:1
Numéro de commande 1409.7608.02
Transmission line probe, 8 GHz, passive
Numéro de commande 1418.7007.02
Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface
Numéro de commande 1410.4080.02
Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1410.3502.02
Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1410.4309.02
Active single-ended probe, 3 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1418.7307.02
Active single-ended probe, 6 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1410.4715.02
Active differential probe, 1 GHz, Rohde & Schwarz probe interface
Numéro de commande 1410.4409.02
Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface
Numéro de commande 1410.4609.02
Active differential probe, 3.0 GHz, Rohde & Schwarz probe interface
Numéro de commande 1410.5205.02
Active differential probe, 4.5 GHz, Rohde & Schwarz probe interface
Numéro de commande 1800.4700.02
Modular probe amplifier module, 1.5 GHz
Numéro de commande 1419.3005.02
Modular probe amplifier module, 3 GHz
Numéro de commande 1419.3105.02
Modular probe amplifier module, 6 GHz
Numéro de commande 1419.3205.02
Modular probe amplifier module, 9 GHz
Numéro de commande 1800.5006.02
Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
2.0 GHz, 1:1, 50 kΩ, R&S probe interface
Numéro de commande 1800.5406.02
Power rail probe, 4 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Numéro de commande 1326.0259.02
Multi-channel power probe
1 MHz, 5 MSa/s, 18 Bit, 2 current inputs, 2 voltage inputs
Numéro de commande 1326.0259.04
Multi-channel power probe
1 MHz, 5 MSa/s, 18 Bit, 4 current inputs, 4 voltage inputs
Numéro de commande 1333.0873.02
250 MHz passive high voltage probe
Numéro de commande 1409.7720.02
400 MHz passive high voltage probe
Numéro de commande 1409.7737.02
400 MHz passive high voltage probe
Numéro de commande 1800.2107.02
100 MHz High voltage differential probe
Numéro de commande 1800.2207.02
200 MHz High voltage differential probe
Numéro de commande 1800.2007.02
100 MHz High voltage differential probe
Numéro de commande 1333.0850.02
AC/DC 20 kHz current probe
Numéro de commande 1333.0844.02
100 kHz current probe
Numéro de commande 1409.8204.02
2 MHZ current probe
Numéro de commande 1409.7750K02
10 MHZ current probe
Numéro de commande 1409.8210.02
10 MHZ Current probe
Numéro de commande 1409.7766K02
100 MHZ current probe
Numéro de commande 1409.8233.02
100 MHZ current probe
Numéro de commande 1409.7772K02
120 MHz current probe
Numéro de commande 1801.4932.02
120 MHz current probe
Numéro de commande 1147.2736.02
E and H near-field probe set
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found
Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz
1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").
2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.
3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.
4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.
5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :
Prix : 1x oscilloscope numérique R&S®RTB2000
6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.
7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.
8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.
9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.
10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.
11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.
12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.
13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.
* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.