52 결과
How can I delete Cal Kit Data?
How can I start a SSST calibration?
What is the function of "Resolve pool link" in the calibration manager?
Loading an S-parameter file from a PC into a memory trace
I trigger this single sweep with the RSZVB_Send_Trigger_and_Wait_for_OPC driver, but this driver does not wait for the complete 10 sweeps. If I don't use averaging, this program is works.
Control external Generator in Fast Sweep Mode
Converting the real and imaginary numbers to magnitude in dB and phase in degrees.
What is the correct pin layout of the DC inputs on the network analyzer's rear panel?
I got a calibration kit with a sliding match standard. But there are no correction values for the NWA supplied.
I want to use Port 1 and Port 3, so I tried to switch them on by setting the value to 1 (the default value) and to switch off Port 2 and Port 4 by setting the value to 0. But this does not work. How do I set the ports?
Which settings should I use for the Transform Time Domain mode?
Longer sweep times in CW mode
Calculate the mixed-mode S-parameter from an S4P file
How to use the User Def. Math functionality
Connection of an external Monitor to ZVA
All four S-parameter remote set up
Connect Generator via LAN
Calibration of two channels simultaneously with remote commands
VNA - 교정에 슬라이딩 매치가 꼭 필요한가요?
ZNA/ZVA - ZCxxx 컨버터 설치 방법
TRL calibration - middle of line or end of line
Remote Control: Change the byte order in FORMAT REAL
License Keycode for VNAMUC is not accepted
Restore the Auto Logon Configuration
Deactivation of Ports
Reverse sweep / backward sweep
scpi 명령어를 사용하여 트레이스 값의 쿼리를 실행하는데, y값만 도출됩니다. x값(주파수)도 얻을 방법이 있나요?
Recall of user's own calibration kits and connectors via remote
Mixer measurement: Conversion gain too low
Source Power Calibration is very slow.
Dividing a trace by two
4 Port Calibration with a 2 Port automatic calibration kit possible?
How can I switch from remote to local state via remote control?
Improve the calibration procedure for different setups
Sending a remote Control Command internally
Calibration with Auto Cal Kits and inserted attenuators
Cannot use internal display and external monitor together at the same time.
Differential data export
I have set my VNA to single sweep mode and switched on averaging with a factor of 10. But when I restart the single sweep, it stops after 1 sweep and the averaging is not done.
Calibration Unit and Remote Calibration
German keyboard driver
Changing the update display rate of a sweep with many sweep points.
모든 트레이스 데이터 쿼리를 한 번에 실행하는 방법이 있나요?
How can I change the display resolution when I use an external monitor?
Reading the magnitude (dB) and phase (degrees) values directly
Most accurate way to measure the length of a cable with a VNA
How to export Touchstone s2p files?
How to bisect the result in dB with Trace Mathematics
Login Password for ZVA
ZVA - 포트 3과 4의 "1패스 2포트" 교정
Calibrating a vector network analyzer (VNA) with different connectors on each port
How do I calculate these frequency points when I have a logarithmic sweep and know the center frequency, the span and the number of sweep points?