R&S®NTS Power transfer standards

The very definition of RF power

R&S®NTS Power transfer standards
Weitere Details anzeigen
R&S®NTS Power transfer standards
Weitere Details anzeigen
R&S®NTS Power transfer standards
Weitere Details anzeigen
R&S®NTS Power transfer standards
Weitere Details anzeigen

Hauptmerkmale

  • Designed for RF power traceability applications
  • Makes for easy replacement of legacy thermistor mounts in microcalorimeter applications with analog, passive sensor design 
  • Dedicated thermoelectric power detector chip with improved linearity
  • Excellent RF properties
  • For use at national metrology institutes, accredited calibration labs and industrial customers

The very definition of RF power

The R&S®NTS Series thermocouple power sensors are engineered to serve as RF power measurement standards. With their passive, analog-only design, the R&S®NTS family can be used as a microcalorimeter based primary measurement standard or as a secondary or transfer standard. A proprietary thermoelectric detector chip developed specifically for the NTS supports RF-DC substitution at the metrology grade level.
The R&S®NTS family has various models covering the frequency range from DC to 170 GHz.
Several NTS models are available with coaxial and waveguide RF connectors. All models have a high maximum input power of + 20 dBm, fast settling times and extremely flat frequency response.

Merkmale & Vorteile

Designed for high precision applications

RF primary and secondary standard solution for NMIs (national metrology institutes) and accredited calibration laboratories

Precision measurements are important in industrial quality assurance and are necessary for top-quality industrial production. Instruments must be calibrated in line with international standards for quality management systems (DIN EN ISO 9000) as well as product liability and environmental protection requirements. Test results are reliable only when they are made by calibrated instruments whose calibrations can be traced to national standards.

  National metrology institutes are at the top of the calibration hierarchy and perform substitution measurements with primary measurement standards that trace RF power to the equivalent SI unit, DC power. The measurement is made inside a microcalorimeter to be as precise as possible.
Accredited calibration labs are the next level in the calibration hierarchy. The reference standards used in these calibration labs are calibrated by the national metrology institutes.
In all those applications, the substituted DC power can be measured with the customers own, well known commercial, off-the-shelf DC nanovolt meter with traceable calibration.

The calibration hierarchy
Weitere Details anzeigen

The calibration hierarchy

Upgrade for legacy thermistor mounts

A modern thermoelectric power detector chip revolutionizes the traceability process

Reference standards must be passive and based on thermistors or comparable technology. Yet thermistor mounts have not been used for industrial RF power measurements for decades and the technology has not been developed further. Even though thermistor mounts have great long-term stability - which helps national metrology institutes keep them in working condition – fewer and fewer fully functional samples are available. New frequency bands are also not covered. The power standards are now obsolete because of a new generation of technology in the industry and defective standards can no longer be replaced . R&S®NTS is a high-performing replacement that uses a modern thermoelectric power detector chip. The NTS is designed to easily replace thermistor mounts. The NTS is small enough to fit any microcalorimeter, requires no additional base units and connects directly to existing DC nanovolt meters. The substitution measurement workflow is similar to that for thermistors but with even better performance. Finally, a dedicated R&S application for direct comparison measurements can help with the transition.
  Not only are R&S®NTS RF power standards new parts, but they also are more robust and modern than thermistor standards. Their tiny size and passive measurement method makes them ideal replacements for outdated thermistors. They replace legacy standards, but also cover new frequency bands and RF connectors, allowing commercialization of new frequency bands for current and future wireless communication standards, such as 6G.

Two R&S®NTS170TWGs mounted in a microcalorimeter experimental setup for traceable calibration using the DC substitution principle. The active sensor is supplied with a high-frequency signal, while the passive sensor serves as a reference. A differential temperature measurement in the millikelvin range uses a thermopile to determine the effective power sensor efficiency. © Physikalisch-Technische Bundesanstalt
Weitere Details anzeigen

Two R&S®NTS170TWGs mounted in a microcalorimeter experimental setup for traceable calibration using the DC substitution principle. The active sensor is supplied with a high-frequency signal, while the passive sensor serves as a reference. A differential temperature measurement in the millikelvin range uses a thermopile to determine the effective power sensor efficiency. © Physikalisch-Technische Bundesanstalt

Technical properties of thermoelectric power detector chip

Technological leap over thermistor technology based on proven R&S®NRP technology

Tracing RF power is an analog measurement, which always has a margin of error. Measurement equipment with the best available RF properties helps minimize such uncertainty. Enter the R&S®NTS thermoelectric power detector chip. The technology was first used in R&S®NRP RF power sensors over two decades ago and has been continually improved with proven long-term reliability and stability.
  The advanced transducer technology in the R&S®NTS was designed for the highest RF substitution measurement accuracy requirements. It has excellent matching and a flat frequency response for easy and reliable measurements. The technology also has a high maximum power rating for wide overall dynamic range. Two symmetrical RF and DC heaters inside the transducer create near-perfect RF-DC substitution.

Optimized transducer design ensures high linearity in substitution measurements, while the operating point influence on the calibration factor from the R&S®NTS was reduced to ppm per mW.  
R&S®NTS sensors feature a 4-wire heater connection for current sourcing and voltage control for precise measurements of substituted DC power.
The DC lines inside the NTS are optimized for low impedance to minimize heating loss outside the transducer.

  R&S®NTS devices feature an additional internal temperature sensor to aid in correction. Even the tiniest temperature effects can be compensated to keep uncertainty to an absolute minimum and optimize settling times in the microcalorimeter.

R&S®NTS thermoelectric power detector chip
Weitere Details anzeigen

R&S®NTS thermoelectric power detector chip

Reduce measurement times

Thermoelectric power detector chip improves and shortens calibration cycle

Measurement points cost time, and time is money. R&S®NTS revolutionizes calibration workflows over thermistors by using their key thermoelectric power detector chip performance properties. The flat frequency response requires fewer measurement points while maintaining accurate calibration. High sensitivity results in a higher output signal for less noise and shorter measurement times. Lastly, the short settling time reduces the required measurement time per calibration point.

Frequency response curve: NTS vs. competition
Weitere Details anzeigen

Frequency response curve: NTS vs. competition

Wide range of models

Portfolio from DC to 170 GHz

The R&S®NTS family of RF power transfer standards currently has 5 coaxial models from DC to 67 GHz, including N, 3.5mm, 2.92mm, 2.4mm and 1.85mm RF connectors.
  Especially national metrology institute customers prefer waveguide connectors from 18 GHz onwards for ultimate precision. NTS170TWG with its WR 6.5 waveguide connector already covers D band from 110 GHz to 170 GHz. 
  The R&S®NTS with modified RF reflection factors is also available as open, short, and mismatched standards for selected connector types. The special variants are used to determine the microcalorimeter correction factor.
  All R&S®NTS models have a push-pull-connector for secure connections, compact size and low thermal mass. An optional feature is device identification with the 1-Wire® protocol (passive in calibration mode) to help with automated calibration workflows.

R&S®NTSxT(WG) family of RF power transfer standards
Weitere Details anzeigen

R&S®NTSxT(WG) family of RF power transfer standards

Calibration hierarchy in your hand

R&S®NTS ensure self-sufficiency for RF traceability and calibration

RF measurement devices, whether RF Power Sensors, Signal Generators or others, must be regularly calibrated to comply with RF specifications.
  The R&S®NTS has the tools for the RF power traceability required to calibrate RF measurement device amplitude. Customer no longer need RF amplitude calibration providers, such as accredited calibration labs or T&M equipment manufacturers.
  Along with the R&S®NRPC calibration solution, R&S®NRP RF power sensors and a wide range of RF signal generators, Rohde & Schwarz has a full range of equipment for traceable RF calibration along the whole calibration hierarchy.

R&S®NTS RF power standards ensure adherence to the calibration pyramid hierarchy
Weitere Details anzeigen

R&S®NTS RF power standards ensure adherence to the calibration pyramid hierarchy

Verfügbare Modelle

Verfügbare Optionen

Informationen anfordern

Haben Sie Fragen oder benötigen Sie weitere Informationen? Nutzen Sie hierzu einfach unser Kontaktformular und wir setzen uns umgehend mit Ihnen in Verbindung.

Marketing-Einverständniserklärung

Ihre Anfrage wurde erfolgreich versendet. Wir nehmen in Kürze Kontakt mit Ihnen auf.
An error is occurred, please try it again later.
Allgemeine Informationen und rechtliche Hinweise

Unverbindliche Preisempfehlung des Herstellers (UVP). Der dargestellte Preis versteht sich ohne USt. Preise und Angebote richten sich nur an Unternehmer und nicht an private Verbraucher.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Teilnahmebedingungen für das Gewinnspiel „10 Jahre Oszilloskope von Rohde & Schwarz“

1. Das Gewinnspiel „10 Jahre Oszilloskope von Rohde & Schwarz“ (nachfolgend „Gewinnspiel“ genannt) wird organisiert von der Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 München, Deutschland, Tel. +49 89 41 29 0 (nachfolgend „R&S“ genannt).

2. Teilnehmer können sich zwischen dem 1. Januar 2020 und dem 31. Dezember 2020 mit ihrem Namen, Firmennamen und ihrer geschäftlichen E-Mailadresse registrieren.

3. Die Teilnahme am Gewinnspiel ist kostenlos und nicht vom Erwerb einer Ware oder Dienstleistung abhängig.

4. Teilnahme- und gewinnberechtigt sind nur juristische Personen. Natürlichen Personen ist es nicht gestattet, in ihrem eigenen Namen und auf eigene Rechnung teilzunehmen. Sie dürfen das Teilnahmeformular lediglich in ihrer Eigenschaft als Vertreter einer juristischen Person und im Namen und Auftrag dieser juristischen Person einreichen.

5. Zu gewinnen gibt es innerhalb des Zeitraums vom 1. Januar 2020 bis zum 31. Dezember 2020 jeweils eines von zehn R&S®RTB2000 Oszilloskopen:

Preis: 1x R&S®RTB2000 Digitales Oszilloskop

6. Die Preisverlosung findet am Hauptsitz von Rohde & Schwarz, Mühldorfstraße 15, 81671 München, statt. Die Gewinner werden innerhalb von fünf (5) Werktagen per E-Mail benachrichtigt.

7. Der bevollmächtigte Vertreter der juristischen Person hat die Inanspruchnahme des Gewinns gegenüber R&S zu bestätigen. Bleibt diese Inanspruchnahme aus oder erfolgt keine Antwort innerhalb von zwei (2) Wochen, wird ein neuer Gewinner ermittelt. Wenn innerhalb von vier (4) Wochen kein Gewinner feststeht, endet die Verlosung und der Preis verfällt.

8. Mitarbeiter von R&S und an der Konzeption und Umsetzung des Gewinnspiels beteiligte Personen sowie ihre Familienmitglieder sind nicht berechtigt, das Teilnahmeformular auszufüllen.

9. Eine Barauszahlung oder ein Umtausch von Preisen ist ausgeschlossen. Preise sind nicht übertragbar. Alle Steuern, Abgaben, Zölle, Gebühren und sonstigen Entgelte, die im Land des Teilnehmers erhoben werden, sind vom Teilnehmer zu tragen.

10. Personenbezogenen Daten werden ausschließlich für die Durchführung des Gewinnspiels verwendet und innerhalb von vier (4) Wochen nach Ende des Gewinnspiels gelöscht, sofern nichts anderes vereinbart wurde.

11. Ein Verstoß gegen diese Teilnahmebedingungen berechtigt R&S, den jeweiligen Teilnehmer von der Teilnahme auszuschließen. Handelt es sich bei dem ausgeschlossenen Teilnehmer um einen bereits ausgelosten Gewinner, kann der Gewinn nachträglich aberkannt werden. Wird ein Preis aufgrund eines Verstoßes gegen diese Teilnahmebedingungen nachträglich aberkannt, ist er von dem jeweiligen Teilnehmer auf dessen Kosten an die oben unter Punkt 1 angegebene Anschrift von R&S zurückzusenden, und es wird ein neuer Gewinner ermittelt.

12. Teilnehmer haben keinen Gewinnanspruch. Der Rechtsweg ist ausgeschlossen.

13. Das Gewinnspiel und jedes daraus zwischen R&S und dem jeweiligen Teilnehmer entstehende Vertragsverhältnis unterliegt deutschem Recht und gilt unter Ausschluss kollisionsrechtlicher Regelungen. Für alle Streitigkeiten, die sich mittelbar oder unmittelbar aus der Teilnahme an diesem Gewinnspiel ergeben, wird München als ausschließlicher Gerichtsstand vereinbart.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.