Key Facts
- 100 kHz to 4.5 GHz unidirectional 2 port VNA
- Frequency range can be extended to 8.5 GHz
- Test set can be expanded for bidirectional measurements
- Simple touchscreen operation
- Solid RF performance
Key Facts
The base model of the R&S®ZND network analyzer performs unidirectional measurements up to 4.5 GHz. The R&S®ZND can be expanded to perform bidirectional measurements and its frequency range can be extended to 8.5 GHz. The large R&S®ZND touchscreen is easy to operate and ideal for S-parameter measurements, even when many diagrams are needed. Time domain measurements can also be added for even more functions.
Quick Links
The analyzer that grows with your requirements
The R&S®ZND test set can be configured to individual requirements. The test set can be set up for unidirectional operations or extended for bidirectional operations, depending on user needs. The frequency and power sweep ranges can be easily extended.
Unidirectional/bidirectional test set
Unidirectional test set (black) of the R&S®ZND, expansion for bidirectional test set (blue) and extended power range options (grey)
Large display and clearly structured user interface
The 12.1" touchscreen is large enough to clearly show several diagrams on a single screen or all measurement details. The flat user interface menu structures allow for efficient measurement setups as well as uncomplicated and quick measurement starts.
The right calibration method for every application
The R&S®ZND offers a wide variety of calibration methods for a variety of measurements depending on the test set configuration. Rohde & Schwarz has both a manual calibration kit or an automatic calibration unit for even faster calibration.
Simplifying test automation for complex measurements
The R&S®ZND SCPI recorder automatically generates SCPI command sequences from user instrument operations. Captured command sequences can be exported in different programming languages such as C++, Python and MATLAB® and be directly used. The R&S®ZND SCPI recorder is a powerful tool to implement test automation for development, verification and production. It simplifies implementation of complex measurements and optimizes workflow efficiency.
Measurements up to 24 ports
The number of ports of a bi-directional R&S®ZND can be easily extended when used in combination with the R&S®ZN-Z84 switch matrix. The R&S®ZND provides a comprehensive solution for multiport modules or multiple devices with up to 24 ports. Automatic calibration unit, R&S®ZN-Z154 enables quick and accurate setup calibration for up to 24 ports. Additionally, when equipped with the SNP assistant measurement wizard, the R&S®ZND-K100 option intelligently guides the user through all the required measurements with minimal and optimal reconnection steps. The measurement result is conveniently generated in the end as a higher order Touchstone file.
Easy to define test items with SNP assistant
The SNP assistant presents the DUT topology definition in an intuitive color-coded matrix.
Enhanced tools for in-fixture and PCB testing
The R&S®ZND supports various embedding/deembedding techniques that can be used to eliminate the effects of different test fixtures and precisely characterize the DUT. Supported deembedding algorithms are fully integrated into the R&S®ZND user interface and are based on industry-recognized techniques in line with IEEEP370. Options includes:
Order Number 1316.2459.05
Handler I/O
(Universal interface)
Order Number 1338.1578.02
High output power
Order Number 1328.5358.02
GPIB interface
Order Number 1326.7760.02
Additional removeable harddisk
Order Number 1338.1703.02
Additional removeable SSD
Order Number 1175.3040.00
19" Rack Adapter
Order Number 1321.1828.02
Calibration unit, 1 port, N (f), 2 MHz to 4 GHz
Order Number 1321.1828.12
Calibration unit, 1 port, N (f), 1 MHz to 6 GHz
Order Number 1328.5306.02
Extended frequency range, unidirectional, 8.5 GHz
Order Number 1328.5393.02
Time domain analysis (TDR)
Order Number 1350.5070.02
Distence to fault (DTF)
Order Number 1328.5312.02
Full test set, Base Unit, bidirectional, 4.5GHz
Order Number 1328.5329.02
Full test set, bidirectional, 8.5 GHz
Order Number 1328.5335.02
Extended power range for R&S®ZND
Order Number 1328.5412.02
Extended frequency range, full test set, bidirectional, 8.5 GHz
Order Number 1326.8089.02
Freq. resolution 1 mHz
Order Number 1338.9356.02
SNP assistant
Order Number 1328.8670.02
EAZY De-embedding (EZD) based on IEEE 370
for R&S®ZND
Order Number 1328.8686.02
In-Situ De-embedding (ISD) that covers IEEE 370
for R&S®ZND
Order Number 1328.8692.02
Smart Fixture De-embedding (SFD)
for R&S®ZND
Order Number 1328.8705.02
Delta-L 4.0 PCB characterization
for R&S®ZND
Order Number 1350.5311.02
HUMS software option
Health and Utilization Monitoring Service for R&S®ZND (software license)
Order Number 1328.8534.10
Torque Wrench, 0.45 Nm
for 1.0 mm connectors, 6 mm width across flats
Order Number 1328.8534.11
Torque Wrench, 0.23 Nm coupling torque
for 1.0 mm connectors with 6 mm width across flats
Order Number 1328.8534.12
Torque Wrench, 0.34 Nm
for 1.0 mm connectors, 6 mm width across flats
Order Number 1328.8534.19
Torque Wrench, 0.9 Nm
Order Number 1328.8534.71
Torque Wrench, 1.5 Nm
for type N connectors, 20 mm width across flats
Order Number 0272.4010.50
Attenuator
0 Hz to 12.4 GHz, m/f 3 dB, 2 W
Order Number 0272.4110.50
Attenuator
0 Hz to 12.4 GHz, m/f 6 dB, 2 W
Order Number 0272.4210.50
Attenuator
0 Hz to 12.4 GHz, m/f 10 dB, 1 W
Order Number 0272.4310.50
Attenuator
0 Hz to 12.4 GHz, m/f 20 dB, 1 W
Order Number 1073.8695.03
High-Power Attenuator, 50 W
0 Hz to 2 GHz
Order Number 1073.8695.06
High-Power Attenuator, 50 W
0 Hz to 2 GHz
Order Number 1073.8695.10
High-Power Attenuator, 50 W
0 Hz to 2 GHz
Order Number 1073.8695.20
High-Power Attenuator, 50 W
0 Hz to 2 GHz
Order Number 1073.8695.30
High-Power Attenuator, 50 W
0 Hz to 2 GHz
Order Number 1073.8495.03
High-Power Attenuator, 100 W
0 Hz to 2 GHz
Order Number 1073.8495.06
High-Power Attenuator, 100 W
0 Hz to 2 GHz
Order Number 1073.8495.10
High-Power Attenuator, 100 W
0 Hz to 2 GHz
Order Number 1073.8495.20
High-Power Attenuator, 100 W
0 Hz to 2 GHz
Order Number 1073.8495.30
High-Power Attenuator, 100 W
0 Hz to 2 GHz
Order Number 1035.1700.52
High-Power Attenuator, 50W
0 Hz to 6 GHz, 20 dB
Order Number 1303.7840.02
50 Ohm broadband limiter
Order Number 0272.4510.50
Precision Termination, 75 Ω
1 W, DC to 3 GHz, N (m)
Order Number 0272.4910.50
Termination, 50 Ω
1 W, DC to 4 GHz, N (m)
Order Number 0200.0019.55
UHF Termination , 50 Ω
0 Hz to 2 GHz, 100 W, N (f)
Order Number 0289.8966.00
Feedthrough Termination, 50 Ω
0.5 W, DC to 1 GHz, BNC (m/f)
Order Number 0844.9352.02
Feedthrough Termination, 50 Ω
2 W, DC to 500 MHz, BNC (m/f)
Order Number 0358.5714.03
Matching Pad 50/75 Ω, series resistor 25 Ω
0 Hz to 3.3 GHz
Order Number 0800.6612.52
Power Splitter, 2x 50 Ω
0 Hz to 2.7 GHz
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found
Termos e condições do sorteio de prêmios: 10 anos dos osciloscópios da Rohde & Schwarz
1. O sorteio de prêmios “10 anos dos osciloscópios da Rohde & Schwarz” (no presente, referido como “Sorteio”) é organizado pela Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munique, Alemanha, tel. +49 89 41 29 0 (doravante referida como “R&S”).
2. Todos os participantes podem se inscrever durante o período de 1º de janeiro de 2020 a 31 de dezembro de 2020, informando seu nome, nome da empresa e e-mail comercial.
3. A participação é gratuita e não depende da compra de mercadorias ou serviços.
4. O sorteio está aberto somente a pessoas jurídicas e apenas às pessoas jurídicas que possam ganhar os prêmios. Pessoas físicas não poderão participar em nome e interesse próprios, mas como representantes de uma pessoa jurídica, devendo preencher a ficha de participação em nome e segundo o interesse da pessoa jurídica.
5. Os prêmios a serem entregues são 1 de 10 R&S®RTB2000, no período de 1º de janeiro de 2020 a 31 de dezembro de 2020:
Prêmio: 1 osciloscópio digital R&S®RTB2000
6. O sorteio ocorrerá na sede da R&S, em Munique, à Muehldorstrasse 15, 81671. O ganhador dos prêmios será avisado por e-mail no prazo de cinco (5) dias úteis.
7. O representante autorizado da pessoa jurídica informará à R&S sobre a aceitação do preço. Caso a aceitação seja negada ou se não houver resposta em até duas (2) semanas, um novo ganhador será sorteado. Se não for possível definir um ganhador no prazo de quatro (4) semanas, o sorteio se encerrará e o prêmio prescreverá.
8. Aos funcionários da R&S e seus familiares, bem como às pessoas familiarizadas com o processo do sorteio e seus familiares, é vetado o preenchimento da ficha de participação.
9. Não são permitidos equivalente em dinheiro ou troca de prêmios. Os prêmios são intransferíveis. Todos os impostos, tributos, encargos, taxas e outras cobranças tributáveis no país do participante serão arcadas pelo participante.
10. Dados pessoais somente serão processados para os fins deste sorteio e excluídos quatro (4) semanas após o sorteio, se não acordado de outro modo.
11. O participante que não cumprir os presentes Termos e Condições estará sujeito à desclassificação pela R&S da participação neste concurso. Neste caso, os prêmios também poderão ser retirados retroativamente. Se um prêmio estiver sujeito à retirada retrospectiva por motivo de incumprimento dos presentes Termos e Condições, ele deverá ser devolvido pelo respectivo participante, às suas expensas, para o endereço da R&S mencionado na disposição N.1, e um novo ganhador será sorteado.
12. Os participantes não podem reivindicar os prêmios do sorteio e não são autorizados recursos legais neste sentido.
13. O sorteio e a relação contratual decorrente, entre a R&S e o respectivo participante, serão regidos e interpretados de acordo com as leis da Alemanha, sem dar efeito ao princípio do conflito de leis. Os tribunais de Munique, Alemanha, gozarão de jurisdição exclusiva em caso de disputa decorrente, direta ou indiretamente, da participação neste concurso.
* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.