RF-Level Test System +20 dBm to -130 dBm
18-Feb-2011 | AN-No. 1MA21
The R&S®ZNB measures the signal integrity on the PCB, taking the needed test fixtures and probes into consideration – a complete solution in a compact format.
25-Mar-2020
This application note describes a method using the R&S®ZNA analyzer family to measure group delay of mixers and frequency converters with an embedded local oscillator very accurately.
11-Jul-2019 | AN-No. 1EZ81
High Speed Downlink Packet Access (HSDPA) Test and Measurement Requirements
01-Feb-2005 | AN-No. 1MA82
Remote Emulation with the R&S<sup>®</sup>SMC100A Signal Generator
28-Feb-2012 | AN-No. 1GP90
The shift from ICE to EVs introduces new EMC challenges. This note discusses dynamic EMC test systems and the collaboration between Rohde & Schwarz and AVL to develop unified test systems.
11-Mar-2025
LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server
07-Jul-2003 | AN-No. 7BM41
R&S VCS-4G facilitates migration from analog/TDM to VoIP networks
21-Sep-2015
This Application Note gives 10 useful Tips & Tricks for the users of Rohde & Schwarz attribute-based instrument drivers.
30-Jan-2017 | AN-No. 1MA228
The R&S®ZNB vector network analyzer together with the R&S®HF907 double-ridged waveguide horn antenna provides fast and accurate TD SVSWR measurements in line with ANSI C63.25.
06-Aug-2018
The R&S®SMA100B offers outputs for the analog input signal of the ADC as well as the clock input signal in one single instrument - both with outstanding signal purity.
11-Jan-2021 | AN-No. 1GP66
MIPI D-PHY is a low-power, cost-effective physical layer interface, essential in mobile devices and advanced technology systems. It's a high-speed, source-synchronous interface used in smartphone cameras, smartwatch displays, drones, in-car entertainment, automobile cameras, and radar sensors. This application note explores MIPI D-PHY's features, functionality, and testing practices for device compliance, addressing common issues. It highlights Rohde & Schwarz's equipment for ensuring compatibility and solving issues with MIPI D-PHY, aligned with MIPI D-PHY specification version 2.5.Developed by the MIPI Alliance, D-PHY connects cameras and displays to a host processor via CSI-2 or DSI protocols. It features a master-slave, asymmetrical design for reduced link complexity. Key aspects include a unidirectional clock, optional data signal directions, different data rates for half-duplex operation, point-to-point communication, and high-speed (HS) and low-power (LP) modes for data transfer and battery preservation. In HS mode, D-PHY uses differential signaling with specific impedance, while in LP mode, it operates in a single-ended manner with high impedance termination.The application note from Rohde & Schwarz provides insights into characterizing and debugging MIPI D-PHY, offering conformance verification with MIPI Alliance standards and protocol decoding options.
31-Jan-2024 | AN-No. 1SL410
Battery cycle tool for the R&S®NGU401/NGU201/NGM200/NGL200
02-May-2023
R&S®Server-Based Testing helps reduce test times for 5G New Radio multicarrier signals - each component carrier can be analyzed independently and in parallel.
13-Sep-2021
.NET programming interface for R&S®GTSL and R&S®EGTSL
08-Mar-2016 | AN-No. 1SE001
Audio performance testing solution for the connected car
26-Aug-2017
Distance-To-Fault (DTF) Measurement in 75 Ohm Systems with the R&S FSH3-TV
21-Sep-2006 | AN-No. 7BM60
Measurement of Frequency Settling Time of Synthesizers and Transmitters
12-Feb-1999 | AN-No. 1MA15
This application note and associated application software may be used to conduct psychoacoustic speech quality evaluation for Voice over LTE (VoLTE) connections. The measurements are based on recommendations ITU-T P.862 and ITU-T P.863. The included software sequence performs decoder/encoder calibration, connection setup for the UE under test and subsequent speech quality analysis.
21-Feb-2014 | AN-No. 1MA204
Monitoring solutions for operators of security radio networks for police, rescue services, ambulances, fire brigades and radio and TV broadcasting transmitters and other regional and national services.
04-Sep-2006
RF chipset verification for UMTS LTE (FDD) with R&S<sup>®</sup>SMU200A and R&S<sup>®</sup>FSQ
19-Dec-2008 | AN-No. 1MA138
Frequency Range Extension of Spectrum Analyzers with Harmonic Mixers
05-Mar-1999 | AN-No. 1EF43
This application note explains how to use the SMW for testing higher order MIMO systems by presenting different key applications.
24-Feb-2016 | AN-No. 1GP97
In this application note we discuss potential 5G waveform candidates, list their advantages and disadvantages and compare them to OFDM.
10-Jun-2016 | AN-No. 1MA271
AutoCal: Automatic Calibration of Vector Network Analyzer ZVR
28-Jul-1998 | AN-No. 1EZ30
The first part of this educational note presents the applications for and the most important types of signal generators. This is followed by a description of the construction and functioning of analog and vector signal generators.
03-May-2016 | AN-No. 1MA225
R&S SFQ to R&S SFU SCPI Transcription + Cross-Reference List
23-Jun-2006 | AN-No. 7BM56
An error in DVB-T2 signal feed to the transmitter can cause failure of the entire DVB-T2 network. For this reason, the established ETSI TR 101 290 DVB measurement guidelines have been expanded to include measurements for the new T2-MI interface. The instruments of the R&S DVMS family monitor T2-MI signals by performing these newly defined measurements and even provide in-depth analysis of these signals.
01-Sep-2011