Aerospace protocols

Trigger and decode oscilloscope software package

Aerospace protocols
Ingrandisci immagine
Aerospace protocols, software

Key Facts

  • Supports multiple aerospace protocols, including: MIL-STD-1553, ARINC 429, SpaceWire
  • Bus configuration in seconds with auto detection of data rates and thresholds
  • Display decoded protocols as a color-coded honeycomb in the waveform diagram or in tabular format
  • Reliable triggering on protocol details such as frame start, frame content and errors
  • Powerful search and navigation capabilities
  • Multi-domain icon

Aerospace trigger and decode
 

R&S®RTO and R&S®RTP oscilloscopes supports triggering and decoding of MIL-STD-1553, ARINC 429, SpaceWire signals. R&S®MXO oscilloscopes support MIL-STD-1553 and ARINC 429 decoding. You can set up decoding in seconds. Results can be viewed as color-coded protocol frames and/or in table format for detailed analysis. Errors are identified reliably and efficiently with the hardware-accelerated trigger. You can trigger on protocol details such as frame start, frame content and errors.

Features & benefits

Fast bus setup

The configuration for any given protocol is accomplished in just a few steps starting from the app cockpit. Once the bus to decode has been chosen, the connected channels have been selected and the correct levels have been set, decoding begins automatically.

Ingrandisci immagine

Simple and quick configuration of aerospace decoding protocols

Color-coded protocol display

You can analyze decoded bus frames using a color-coded data overlay over the bus signal. Address and data content can be displayed in hex, bin and ASCII format. The flexible screen setup always gives you an excellent overview. Additionally, the protocols can be displayed in a concise table.

Ingrandisci immagine

Aerospace protocol details displayed color-coded in the waveform and result table

Strong trigger capability

Trigger on specific aerospace bus packets, data and errors

Reliable isolation of protocol events and errors is possible with the protocol-specific trigger. Rohde & Schwarz oscilloscopes are ideal for finding errors quickly thanks to high acquisition rates that decode protocol-specific trigger results. Hardware based triggering on specific protocol content (addresses or data) is available as well as on protocol errors.

Ingrandisci immagine

Select from a comprehensive list of protocol types for triggering to focus the acquisition on the details of interest

Powerful search and navigation capabilities

Comprehensive search functions simplify the analysis of long signal sequences. Search for waveforms based on various criteria, such as signal faults and protocol content. All detected events are shown in a table with timestamps. Individual events can be examined in a zoom window by easily navigating between events.

Ingrandisci immagine

Search for protocol details in long acquisitions

Reliable decoding

The protocol dialog gives users additional settings to help ensure stable and reliable decoding. 

Ingrandisci immagine

Advanced settings for aerospace bus decoding

Available models

Available models
Modelli
Serial standard
Label support
Search

R&S®RTO6-K530

Order Number 1801.7031.02

Serial standard
ARINC 429/MIL-1553/SpaceWire
Label support
Search

R&S®RTP-K530

Order Number 1803.6655.02

Serial standard
ARINC 429/MIL-1553/SpaceWire
Label support
Search

R&S®MXO4-K530

Order Number 1335.5208.02

Serial standard
ARINC 429
Label support
Search

R&S®MXO5-K530

Order Number 1802.1266.02

Serial standard
ARINC 429, MIL-1553
Label support
Search

R&S®MXO5C-K530

Order Number 1803.1430.02

Serial standard
ARINC 429
Label support
Search

Richiedi informazioni

Hai qualche domanda o ti servono altre informazioni? Compila il modulo e ti ricontatteremo al più presto.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.