Meet the latest R&S® EPL EMI test receivers

Meet the latest R&S® EPL EMI test receivers

The new R&S®EPL1001 and R&S®EPL1007 are here

More information

Mix, match and upgrade for your EMI testing

Flexibility and freedom with the newest R&S®EPL EMI test receiver releases

Wouldn’t it be great if you could select the EMI test receiver features and options that you need, while retaining the flexibility to adapt, add and retrofit your instrument as your needs – or budget – changed?

This is the concept behind the two latest additions to the R&S®EPL EMI test receiver family. The R&S®EPL1001 and R&S®EPL1007, which cover EMI measurements up to 1GHz and 7.125 GHz, respectively, are modular in nature, putting the control in your hands. This means, you can configure the base unit to suit your exact needs – from preselection, including a preamplifier, up to a CISPR 16-1-1 compliant test receiver – by selecting the relevant options.

The two new products join the popular R&S®EPL1000 EMI test receiver, which offers quick, precise and fully CISPR 16-1-1 compliant EMI measurements up to 30 MHz.

In other words, complete flexibility to mix, match and upgrade to suit your testing requirements, workflow and budget.

R&S®EPL1000 EMI test receiver

New! Mix, match and upgrade

The new R&S®EPL1001 and R&S®EPL1007 EMI test receivers offer you new levels of freedom and flexibility.

1. Select your frequency range: Choose between the R&S®EPL1001 for EMI measurements up to 1GHz and the R&S®EPL1007 for EMI measurements up to 7.125 GHz.

2. Select the options you need:

  • Basic version: The base unit of both the R&S®EPL1001 and R&S®EPL1007 includes hardware protection, attenuation of strong signals, maximum use of the dynamic range and overload handling to prevent distorted measurement results, EMI detectors and more.
  • Preselection option (EPL1-B2): Includes everything in the base unit as well as improved measurement of broadband interferers and short pulses and measurement of small signals (a preamplifier with 20 dB gain directly attached to the preselection filters).
  • Compliance (EPL1-B2 and EPL1-B1611): Includes full CISPR 16-1-1 compliant EMI test receiver that allows the certification of products.

3. Upgrade at any time: Add options to suit your evolving needs. Other than those listed above, there are many more options and functions to choose from and you can even retrofit the R&S®EPL1001 to cover measurements up to 7.125 GHz, giving you full flexibility and ensuring you never have to pay for what you don’t need … until you need it.

Want to learn more? Speak to one of our experts to find the perfect configuration to suit your needs.

The R&S®EPL family: Speed. Flexibility. Compliance

R&S®EPL1001 and R&S®EPL1007 EMI test receivers

Select the options you need to achieve the speed, flexibility and compliance you want – and upgrade as your needs evolve. The R&S®EPL1001 and R&S®EPL1007 EMI test receivers, which cover up to 1GHz and 7.125 GHz respectively, offer a host of options to meet your EMI testing requirements:

  • Cover frequencies up to 7.125 GHz
  • Choose from a range of options up to full CISPR 16-1-1 compliance
  • Upgrade hardware and software options any time

More information

R&S®EPL1000 EMI test receiver

Perfect for quick, precise and compliant conducted emission measurements up to 30 MHz, the R&S®EPL1000 offers an incredibly low testing time for better analysis and more insights.

  • Fully compliant with CISPR 16-1-1
  • Fast time domain scan
  • Real-time spectrogram function, IF analysis, four-channel rate analysis and more

More information

FAQs

Which options are available for the R&S®EPL1001 and R&S®EPL1007 EMI test receiver?

Both EMI test receivers offer options to suit your budget and testing needs

Basic version: The base unit of both the R&S®EPL1001 and R&S®EPL1007 includes hardware protection, attenuation of strong signals, maximum use of the dynamic range and overload handling to prevent distorted measurement results, EMI detectors and more.

Preselection option (EPL1-B2): Includes everything in the base unit as well as improved measurement of broadband interferers and short pulses and measurement of small signals (a preamplifier with 20 dB gain directly attached to the preselection filters).

Compliance (EPL1-B2 and EPL1-B1611): Includes full CISPR 16-1-1 compliant EMI test receiver that allows the certification of products.

Can I upgrade the R&S®EPL1001 to R&S®EPL1007 specifications?

Yes, the R&S®EPL1001 can be retrofitted to cover EMI measurements up to 7.125 GHz, without the need to purchase a new instrument.

What is the difference between the R&S®EPL1001 and the R&S®EPL1007?

The R&S®EPL1001 covers EMI measurements up to 1 GHz, It can be upgraded to cover EMI measurements up to 7.125 GHz.

The R&S®EPL1007 covers EMI measurements up to 7.125 GHz in its basic version.

What is the difference between the R&S®EPL1000 and the new additions?

The R&S®EPL1000 covers EMI measurements up to 30 MHz and is fully compliant with CISPR 16-1-1. It supports time domain scan and provides preselection with a preamplifier in its basic version. On the other hand, the R&S®EPL1001 and R&S®EPL1007 cover EMI measurements up to 1 GHz and 7.125 GHz, respectively, and are modular in nature, allowing you to select preselection with preamplifier, CISPR 16-1-1 compliance and time domain scan, as needed.

How can I configure an R&S®EPL1001 or R&S®EPL1007 to my requirements?

Great question. You can head over to the product page and follow the configuration steps on your own, request a quote or simply fill out the below form and one of our experts will get in touch with you.

Ready to mix, match and upgrade for your EMI testing? Get in touch.

Do you have questions about the specific instruments? Available options? How to match your specific application needs? Simply fill out this form and one of our experts will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.