243 Ergebnisse
Oszilloskop, RTP High-Performance-Oszilloskop, Automotive-Radar, Pulsanalyse Erfahren Sie mehr über den prinzipiellen Messaufbau für Tests mit dem R&S®RTP High-Performance-Oszilloskop.
This example demonstrates the power of Advanced Eye analysis with the RTP oscilloscope on an Automotive Ethernet PAM4 signal at 5 Gbaud. PAM-N Analysis with the R&S RTP Oscilloscope (Part 3) Learn about key advantages of the PAM-N analysis option on the R&S RTP & RTO6 oscilloscopes together with the Advanced Eye option to characterize and verify signal transitions.
Learn about the RTP toolbar.
PAM-N Analysis with the R&S RTP Oscilloscope (Part 2) Learn about key advantages of the PAM-N analysis option on the R&S RTP & RTO6 oscilloscopes. In combination with the CDR option, obtain the fastest eye diagrams to characterize signal behaviour in seconds.
Damit werden die R&S®RTO und R&S®RTP Oszilloskope zu leistungsstarken, multifunktionalen Debugging-Werkzeugen. Video, TDR/TDT, Oszilloskope, RTO, RTP Charakterisieren Sie Impedanz und Transmissionsdämpfung Ihrer Signalpfade mit der Option zur TDR-/TDT-Analyse der R&S®RTO und R&S®RTP Oszilloskope.
17.09.2020
Rohde & Schwarz stellt Bandbreiten-Upgrades für ausgewählte Oszilloskope ohne Aufpreis zur VerfügungDie Bandbreite ist die wichtigste Eigenschaft eines Oszilloskops. Um Entwicklungsingenieure bei der Bewältigung aktueller und zukünftiger Design-Herausforderungen zu unterstützen, bietet Rohde & Schwarz eine attraktive Aktion für ausgewählte Oszilloskop-Modelle: Beim Kauf eines R&S RTO2000 oder R&S RTP können Kunden jetzt ohne zusätzliche Kosten die Bandbreite erweitern.
A sinus signal with i.e. 10 V peak-peak, frequency 1 MHz is applied. If I choose a vertical scale which is too small the peaks of the waveform are not displayed as they are out of range. Now I activate the digital filter in the “Vertical” menu à “Channel”. The frequency of the filter is also set to 1 MHz. Now even at very small vertical scales (i.e. 50 mV/div) the waveform is displayed completely, see screenshot. But the amplitude can not be correct. What goes wrong here?
01.03.2023
embedded world 2023: Rohde & Schwarz präsentiert modernste Testlösungen für Embedded-SystemeEmbedded-Systeme sind ein zentrales Element heutiger elektronischer Geräte, sei es in Unterhaltungselektronik, Telekommunikation, Industrie, Medizin, Automotive- oder Luftfahrt-Anwendungen. Ein fehlerfreier Betrieb ist hier von entscheidender Bedeutung, und Ingenieure stehen bei der Entwicklung immer kompakterer eingebetteter Systeme, die den heutigen Anforderungen an Effizienz, Sicherheit, Zuverlässigkeit und Interoperabilität gerecht werden, vor komplexen Herausforderungen. Rohde & Schwarz adressiert diese Herausforderungen mit einem umfassenden Sortiment an Messtechniklösungen, die auf der embedded world Exhibition & Conference 2023 in Nürnberg ausgestellt werden.
13.02.2025
Rohde & Schwarz zeigt seine innovativen Testlösungen für Embedded-Systeme auf der embedded world 2025Embedded-Systeme bilden den Kern moderner Elektronikkomponenten und finden sich in Leistungseingangsstufen, Hauptsteuerplatinen, Motoren, Motorsteuerungen, Sensoren und Benutzerschnittstellen. Für jeden Funktionsblock sind umfassende Tests erforderlich, um eine optimale Performance und Zuverlässigkeit sicherzustellen und eine schnelle Markteinführung des endgültigen Produkts zu ermöglichen. Mit seinem umfangreichen Portfolio hochmoderner Testlösungen unterstützt Rohde & Schwarz Entwicklungsingenieure bei der Bewältigung aktueller und neuer Herausforderungen mit Embedded-Systemen: von Energieeffizienz und elektromagnetischen Störungen bis hin zu digitalem Design und Konnektivität.
RTP oscilloscopes can trigger on signals as small as 1/1000th of a vertical division thanks to digital triggering and adjustable hysteresis. 3 12 RTP, oscilloscope, scope, MSO, update rate, trigger, digital trigger RTP- see the difference. Trigger with highest sensitivity at full bandwidth.
The RTP oscilloscope extends traditional de-embedding capabilities with flexible filter structures directly in the acquisition path. This allows waveform correction in real time. For the first time, users can trigger on corrected waveforms and focus on debugging the true device characteristics. 9 12 RTP, oscilloscope, scope, MSO, user interface, tool bar, toolbar RTP- see the difference.
The RTP addresses this with an hardware-based math approach in the acquisition path, enabling for the first time triggering on math signals. 10 12 RTP, oscilloscope, scope, MSO, differential, differential signal, common mode, trigger RTP- see the difference. Benefit from differential signal and common mode beeing calculated in real-time.
This video is a throwback to the European Microwave Week 2024 and takes you on a quick run-through of wideband signal generation and analysis in the sub-THz frequency range, featuring the SFI wideband IF vector signal generator, FC330 H-band converters, and RTP oscilloscope. vector signal generator, FC330, H-band converters, RTP, oscilloscope The Potential of Sub-THz Frequencies with the FC330ST/SR
Lautstärkeregulierung „BEEP“
R&S ScopeSuite – eMMC-Konformitätstest schlägt fehl
Oszilloskop, RTP High-Performance-Oszilloskop, Energiemessung, gepulstes Signal, Mathematikfunktion Erfahren Sie, wie Sie die Energie gepulster Sinussignale mit Hilfe der erweiterten Mathematikfunktionen des R&S®RTP messen können.
FAQ - Decodierung des SENT-Protokolls zeigt CRC-Fehler an
Verbindung von Prüfobjekt und Link-Partner mit Test Fixture RT-ZF2
Wenn ich bei Effektivwert-Messungen einen Offset anwende, ändert sich das Ergebnis. Bei anderen Oszilloskopen konnte ich diesen Effekt nicht feststellen. Wo liegt hier der Fehler?
Das Rohde & Schwarz-Handbuch beschreibt den 1-MOhm-Adapter für Oszilloskope mit einer Eingangsimpedanz von 50 Ohm.
Handbuch von Rohde & Schwarz für den Prüfadaptersatz R&S®RT-ZF2 für Ethernet-Konformitätsprüfungen. Beschreibt die Prüfadapter-Boards und die Messvorbereitungen.
Handbuch von Rohde & Schwarz für den Frequenzumsetzer R&S®RT-ZF3.
The RTP's Zone trigger allowes as the only oscilloscope in the world to isolate events in the time and the frequency domain. 12 12 RTP, oscilloscope, scope, MSO, Zone trigger, spectrum analysis, spectrogram, RF signal RTP- see the difference. Capture infrequent events in the spectrum.
Programmierbeispiele für Oszilloskope.
Handbuch von Rohde & Schwarz für den Prüfadaptersatz R&S®RT-ZF1 für USB 2.0-Konformitätsprüfungen. Beschreibt die Prüfadapter-Boards und die Messvorbereitungen.
Embedding & Equalization with the R&S RTP Oscilloscope (Part 2) Learn about how to configure cable emulation within the Embedding setup dialog
Handbuch von Rohde & Schwarz für die R&S®RT-ZF4 Ethernet Probing Fixture.
Die Oszilloskope R&S®RTO und R&S®RTP lassen Entwickler ab sofort noch tieferen Einblick in ihr Design gewinnen.
Ich habe die Messkurve in eine csv-Datei exportiert. Wenn ich die Datei in Excel öffne, sind die Werte komplett falsch. Wie komme ich auf die richtigen Werte?
Ich habe passive und aktive Tastköpfe verglichen. Anscheinend tritt bei aktiven Tastköpfen erhöhtes Rauschen auf. Was ist der Grund dafür und was kann ich unternehmen, um das Rauschen zu reduzieren?