  • Designed for RF power traceability applications
  • Makes for easy replacement of legacy thermistor mounts in microcalorimeter applications with analog, passive sensor design 
  • Dedicated thermoelectric power detector chip with improved linearity
  • Excellent RF properties
  • For use at national metrology institutes, accredited calibration labs and industrial customers

The very definition of RF power

The R&S®NTS Series thermocouple power sensors are engineered to serve as RF power measurement standards. With their passive, analog-only design, the R&S®NTS family can be used as a microcalorimeter based primary measurement standard or as a secondary or transfer standard. A proprietary thermoelectric detector chip developed specifically for the NTS supports RF-DC substitution at the metrology grade level.
The R&S®NTS family has various models covering the frequency range from DC to 170 GHz.
Several NTS models are available with coaxial and waveguide RF connectors. All models have a high maximum input power of + 20 dBm, fast settling times and extremely flat frequency response.

特長と利点

Designed for high precision applications

RF primary and secondary standard solution for NMIs (national metrology institutes) and accredited calibration laboratories

Precision measurements are important in industrial quality assurance and are necessary for top-quality industrial production. Instruments must be calibrated in line with international standards for quality management systems (DIN EN ISO 9000) as well as product liability and environmental protection requirements. Test results are reliable only when they are made by calibrated instruments whose calibrations can be traced to national standards.

  National metrology institutes are at the top of the calibration hierarchy and perform substitution measurements with primary measurement standards that trace RF power to the equivalent SI unit, DC power. The measurement is made inside a microcalorimeter to be as precise as possible.
Accredited calibration labs are the next level in the calibration hierarchy. The reference standards used in these calibration labs are calibrated by the national metrology institutes.
In all those applications, the substituted DC power can be measured with the customers own, well known commercial, off-the-shelf DC nanovolt meter with traceable calibration.

The calibration hierarchy
詳細を表示する

The calibration hierarchy

Upgrade for legacy thermistor mounts

A modern thermoelectric power detector chip revolutionizes the traceability process

Reference standards must be passive and based on thermistors or comparable technology. Yet thermistor mounts have not been used for industrial RF power measurements for decades and the technology has not been developed further. Even though thermistor mounts have great long-term stability - which helps national metrology institutes keep them in working condition – fewer and fewer fully functional samples are available. New frequency bands are also not covered. The power standards are now obsolete because of a new generation of technology in the industry and defective standards can no longer be replaced . R&S®NTS is a high-performing replacement that uses a modern thermoelectric power detector chip. The NTS is designed to easily replace thermistor mounts. The NTS is small enough to fit any microcalorimeter, requires no additional base units and connects directly to existing DC nanovolt meters. The substitution measurement workflow is similar to that for thermistors but with even better performance. Finally, a dedicated R&S application for direct comparison measurements can help with the transition.
  Not only are R&S®NTS RF power standards new parts, but they also are more robust and modern than thermistor standards. Their tiny size and passive measurement method makes them ideal replacements for outdated thermistors. They replace legacy standards, but also cover new frequency bands and RF connectors, allowing commercialization of new frequency bands for current and future wireless communication standards, such as 6G.

Two R&S®NTS170TWGs mounted in a microcalorimeter experimental setup for traceable calibration using the DC substitution principle. The active sensor is supplied with a high-frequency signal, while the passive sensor serves as a reference. A differential temperature measurement in the millikelvin range uses a thermopile to determine the effective power sensor efficiency. © Physikalisch-Technische Bundesanstalt
詳細を表示する

Two R&S®NTS170TWGs mounted in a microcalorimeter experimental setup for traceable calibration using the DC substitution principle. The active sensor is supplied with a high-frequency signal, while the passive sensor serves as a reference. A differential temperature measurement in the millikelvin range uses a thermopile to determine the effective power sensor efficiency. © Physikalisch-Technische Bundesanstalt

Technical properties of thermoelectric power detector chip

Technological leap over thermistor technology based on proven R&S®NRP technology

Tracing RF power is an analog measurement, which always has a margin of error. Measurement equipment with the best available RF properties helps minimize such uncertainty. Enter the R&S®NTS thermoelectric power detector chip. The technology was first used in R&S®NRP RF power sensors over two decades ago and has been continually improved with proven long-term reliability and stability.
  The advanced transducer technology in the R&S®NTS was designed for the highest RF substitution measurement accuracy requirements. It has excellent matching and a flat frequency response for easy and reliable measurements. The technology also has a high maximum power rating for wide overall dynamic range. Two symmetrical RF and DC heaters inside the transducer create near-perfect RF-DC substitution.

Optimized transducer design ensures high linearity in substitution measurements, while the operating point influence on the calibration factor from the R&S®NTS was reduced to ppm per mW.  
R&S®NTS sensors feature a 4-wire heater connection for current sourcing and voltage control for precise measurements of substituted DC power.
The DC lines inside the NTS are optimized for low impedance to minimize heating loss outside the transducer.

  R&S®NTS devices feature an additional internal temperature sensor to aid in correction. Even the tiniest temperature effects can be compensated to keep uncertainty to an absolute minimum and optimize settling times in the microcalorimeter.

R&S®NTS thermoelectric power detector chip
詳細を表示する

R&S®NTS thermoelectric power detector chip

Reduce measurement times

Thermoelectric power detector chip improves and shortens calibration cycle

Measurement points cost time, and time is money. R&S®NTS revolutionizes calibration workflows over thermistors by using their key thermoelectric power detector chip performance properties. The flat frequency response requires fewer measurement points while maintaining accurate calibration. High sensitivity results in a higher output signal for less noise and shorter measurement times. Lastly, the short settling time reduces the required measurement time per calibration point.

Frequency response curve: NTS vs. competition
詳細を表示する

Frequency response curve: NTS vs. competition

Wide range of models

Portfolio from DC to 170 GHz

The R&S®NTS family of RF power transfer standards currently has 5 coaxial models from DC to 67 GHz, including N, 3.5mm, 2.92mm, 2.4mm and 1.85mm RF connectors.
  Especially national metrology institute customers prefer waveguide connectors from 18 GHz onwards for ultimate precision. NTS170TWG with its WR 6.5 waveguide connector already covers D band from 110 GHz to 170 GHz. 
  The R&S®NTS with modified RF reflection factors is also available as open, short, and mismatched standards for selected connector types. The special variants are used to determine the microcalorimeter correction factor.
  All R&S®NTS models have a push-pull-connector for secure connections, compact size and low thermal mass. An optional feature is device identification with the 1-Wire® protocol (passive in calibration mode) to help with automated calibration workflows.

R&S®NTSxT(WG) family of RF power transfer standards
詳細を表示する

R&S®NTSxT(WG) family of RF power transfer standards

Calibration hierarchy in your hand

R&S®NTS ensure self-sufficiency for RF traceability and calibration

RF measurement devices, whether RF Power Sensors, Signal Generators or others, must be regularly calibrated to comply with RF specifications.
  The R&S®NTS has the tools for the RF power traceability required to calibrate RF measurement device amplitude. Customer no longer need RF amplitude calibration providers, such as accredited calibration labs or T&M equipment manufacturers.
  Along with the R&S®NRPC calibration solution, R&S®NRP RF power sensors and a wide range of RF signal generators, Rohde & Schwarz has a full range of equipment for traceable RF calibration along the whole calibration hierarchy.

R&S®NTS RF power standards ensure adherence to the calibration pyramid hierarchy
詳細を表示する

R&S®NTS RF power standards ensure adherence to the calibration pyramid hierarchy

利用可能なモデル

利用可能なオプション

リクエスト情報

ご質問や詳細な情報のご要望などがございましたら、こちらのフォームよりお気軽にお問い合わせください。担当者よりご連絡させていただきます。

マーケティング・パーミッション

お問い合わせ内容が送信されました。 後ほどご連絡致します。
An error is occurred, please try it again later.
一般および法的情報

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

抽選キャンペーン「10 YEARS ROHDE & SCHWARZ OSCILLOSCOPES」に関する利用条件

1. 抽選キャンペーン「10 YEARS ROHDE & SCHWARZ OSCILLOSCOPES」(以降、「抽選」と呼びます)は、Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0(以降、「R&S」と呼びます)によって主催されます。

2. すべての参加者は、2020年1月1日から2020年12月31日までの期間中に、参加者の氏名、会社名、ビジネス用メールアドレスを入力することで抽選への参加登録を行えます。

3. 参加は無料です。商品またはサービスの購入経験の有無は問いません。

4. 抽選は法人のみを対象としており、賞品獲得者は法人に限られます。個人の場合、自分の名前と自分のアカウントによる参加は認められませんが、法人の名前で、その法人の代理として参加フォームを提出することにより、法人の代表として参加することが可能です。

5. 賞品として、2020年1月1日から2020年12月31日までの期間内に、R&S®RTB2000 10台のうちの1台を獲得できます。

賞品:R&S®RTB2000 デジタル・オシロスコープ

6. 抽選は、ローデ・シュワルツ本社、Muehldorstrasse 15, 81671 Munichで行われます。賞品獲得者には、5営業日以内にメールでお知らせいたします。

7. 法人の正式な代表者が、賞品受け取りの意向をローデ・シュワルツに通知するものとします。受け取り辞退が発生した場合、または2週間以内に返事がない場合は、新たな賞品獲得者が抽選によって選ばれます。4週間以内に賞品獲得者を決定できない場合、抽選は終了し、賞品は没収となります。

8. R&Sの従業員とその家族、および抽選処理の関係者とその家族は、参加フォームへの記入対象から除外されます。

9. 賞品の現金同等物または交換は許可されていません。賞品は譲渡できません。参加者の国で課されるすべての税金、徴収金、関税、手数料、およびその他の料金は、参加者が負担するものとします。

10. 個人データは、本抽選キャンペーンの目的でのみ処理され、別段の合意がない限り、抽選から4週間後に削除されます。

11. これらの利用条件に従わない参加者は、R&Sにより本コンペティションへの参加資格を剥奪される場合があります。その場合、賞品を遡って撤回することもできます。これらの利用条件に違反したために賞品が遡及的に取り下げられた場合、賞品はそれぞれの参加者の負担で「1.」に記載されているR&Sの住所に返送されるものとし、抽選で新たな賞品獲得者が選ばれることになります。

12. 参加者は本抽選の賞品を請求することはできず、この点に関して法的手段を講じることは許可されません。

13. 抽選およびR&Sとそれぞれの参加者との間に発生するいかなる契約上の関係も、法の抵触に頼ることなく、ドイツ法に準拠し、同法に従って解釈されるものとします。本競争への参加により直接的または間接的に生じた紛争については、ドイツのミュンヘンの裁判所が専属管轄権を有するものとします。

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.